![u-blox LEON-G100 ECALL Скачать руководство пользователя страница 79](http://html.mh-extra.com/html/u-blox/leon-g100-ecall/leon-g100-ecall_system-integration-manual_829528079.webp)
LEON-G100 / LEON-G200 - System Integration Manual
GSM.G1-HW-09002-G3
Preliminary
System description
Page 79 of 125
1.13
Schematic for module integration
Figure 44 is an example of a schematic diagram where the LEON-G200-06S module is integrated into an
application board, using all the interfaces of the module.
47pF
SIM Card Holder
CCVCC (C1)
CCVPP (C6)
CCIO (C7)
CCCLK (C3)
CCRST (C2)
GND (C5)
47pF
47pF
100nF
35
VSIM
33
SIM_IO
32
SIM_CLK
34
SIM_RST
47pF
ESD
ESD
ESD ESD
TXD
RXD
RTS
CTS
DTR
DSR
RI
DCD
GND
15
TXD
12
DTR
16
RXD
13
RTS
14
CTS
9
DSR
10
RI
11
DCD
GND
330µF
39pF
GND
10nF
100nF
10pF
LEON-G200-06S
50
VCC
+
100µF
2
V_BCKP
GND
RTC
back-up
u-blox
3.0V GPS Receiver
4.7k
OUT
IN
GND
LDO Regulator
SHDN
SDA
SCL
4.7k
3V8
3V0_GPS
SDA2
SCL2
GPIO3
GPIO4
TxD1
EXTINT0
31
30
23
24
47k
VCC
GPIO2
21
ANT
47
Antenna
3.0V Digital
Audio Device
I2S_RXD
I2S_CLK
I2S_TXD
I2S_CLK
I2S_TXD
I2S_WA
I2S_RXD
I2S_WA
29
28
27
26
20
GPIO1
3V8
Network
Indicator
22
RESET_N
Ferrite Bead
47pF
3.0V
Application
Processor
Open
Drain
Output
19
PWR_ON
100k
Ω
Open
Drain
Output
0
Ω
0
Ω
TP
TP
10uF
Headset Connector
27pF
27pF
27pF
2
5
3
4
6
1
82nH
82nH
18
HS_DET
37
HS_P
42
MIC_GND2
41
MIC_BIAS2
SPK
27pF 27pF
82nH
82nH
MIC
27pF 27pF
39
SPK_N
38
SPK_P
43
MIC_GND1
44
MIC_BIAS1
Connector
Connector
ESD ESD ESD ESD
ESD ESD ESD ESD
0
Ω
0
Ω
TP
TP
0
Ω
0
Ω
TP
TP
TP
22k
330k
3V0_AP
Input
40
Reserved
ESD
Li-Ion
battery
3V8
4
ESD
Charger
GND
V_CHARGE
5
CHARGE_SENSE
Figure 44: Example of schematic diagram to integrate LEON-G200-06Smodule in an application board, using all the interfaces