Operating Manual Spare Parts List
—————————————————————————
Floor Saw FSG513P
Index / Indice 004
10997588 en / 07.06.2017
Страница 1: ...Operating Manual Spare Parts List Floor Saw FSG513P Index Indice 004 10997588 en 07 06 2017 ...
Страница 2: ...cal changes without prior notice Copyright 2005 TYROLIT Hydrostress AG CH 8330 Pfäffikon ZH Switzerland All rights reserved in particular copyrighting and translating rights Printing of this operating manual including extracts from it is prohibited No parts of it may be reproduced in any form or processed using electronic systems duplicated or disseminated without the written permission of TYROLIT...
Страница 3: ...always be readily available at the location where the machine is used The operating manual must be read and used by any person assigned tasks with the machine such as operation including set up repair of malfunctions during operation disposal of production waste maintenance disposal of materials maintenance service inspection or repair and or transport In addition to the operating manual and the r...
Страница 4: ...nal or other use is considered improper The manufacturer supplier is not liable for damages resulting from improper use Compliance with the operating manual and observation of inspection and service requirements are essential components of proper use 1 3 Organizational measures 1 3 1 Always keep the operating manual readily available at the location where the machine is used 1 3 2 In addition to t...
Страница 5: ...e Observe the minimum legal age 1 4 2 Use only trained or instructed staff Clearly establish individual responsibilities for operation set up maintenance and repair 1 4 3 Ensure that only assigned personnel work with the machine 1 4 4 Specify machine operator responsibilities including those pertaining to road traffic regulations and authorize the operator to ignore any instructions from third par...
Страница 6: ... Observe all the setting maintenance and inspection activities and timetables including instructions for replacing parts secondary devices as described in the operating manual Only technically qualified personnel should carry out these activities 1 5 2 2 Brief operating personnel before beginning special operations and maintenance work Appoint supervisory personnel 1 5 2 3 If the machine is comple...
Страница 7: ...regulations when working in enclosed spaces 1 6 3 Noise 1 6 3 1 Wear required personal hearing protection 1 7 Transport 1 7 1 When loading use only hoists and lifting gear with sufficient capacity 1 7 2 Appoint a trained supervisor for the lifting procedure 1 7 3 Machines should be lifted with lifting gear correctly in accordance with the specifications in the operating manual lifting points for l...
Страница 8: ...8 2 Machine description 2 1 Overview of components Item 1 Saw blade protective hood Item 2 Petrol motor Item 3 Steering rod Item 4 Frame Item 5 Water tank Item 6 Cut indicator ...
Страница 9: ...contents 25 l 2 4 Noise level and vibrations Parameter Value Noise level at the ear of the user Leq 92 2 dB A Noise level at workplace LPA 85 8 dB A Sound power level in accordance with ISO 3744 LwA 106 dB A Vibrations DIN EN ISO 5349 2 2 5 m s Value applies under the following condition Travel drive is switched off and the saw blade is not engaged The measurement is performed with the motor under...
Страница 10: ...clean Match direction of rotation of the saw blade arrow on the blade with arrow on the saw hood synchronized saws Install thrust washer and flange nut Put on saw blade protective hood 3 4 Preparations for start Move the Floor Saw into position Guide bar disk and saw blade are over the cut line Open water faucet Start petrol motor see operating manual for motor Set motor to full throttle Slowly in...
Страница 11: ...ed off Saw arm is in horizontal position 4 2 Movement with crane Remove water tank Attach sling equipment with adequate capacity to the jack rings Lift carefully Danger No one may stand under suspended loads Danger Always keep an eye on the Floor Saw 4 3 Securing for transportation Snap brake mechanism Secure Floor Saw via handling device ...
Страница 12: ... motor Secure Floor Saw by snapping the brake mechanism 6 Maintenance 6 1 Servicing Before starting any maintenance work activate brake item 13 shut down motor Maintenance work daily weekly monthly Clean Floor Saw thoroughly ATTENTION Cleaning with steam jet is not permitted X Check the oil level of the motor X Change motor oil see operating manual for motor ATTENTION Place a suitable oil receptac...
Страница 13: ...ter V belt slips Motor does not produce full power Replace saw blade Clean water cooling system See point 7 3 and 7 4 See operating manual for motor Floor Saw does not start Motor damage or incorrect operation See operating manual for motor Please follow the motor manufacturer s operating manual 7 3 Check the V belt tension Remove protective cap With medium force it should be possible to depress t...
Страница 14: ... 4 Parts which are subject to normal wear and tear are not covered by this warranty Refer to Wearing part terms in the appendix 5 The warranty service will only be undertaken providing that the machine has been correctly used handled serviced and cleaned in accordance with the operating instructions and the technical integrity has been preserved i e that only original TYROLIT Hydrostress AG consum...
Страница 15: ... elements such as guide beads guide bushes guide rails rollers bearings and anti slip supports Electromotor Clamps of quick release systems Flushing head seals Friction and anti friction bearings Shaft sealing rings and seals Friction and overload couplings brake devices Carbon brushes collectors Easy release rings Adjusting potentiometers and manual control elements Fuses and lamps Auxiliary and ...
Страница 16: ...spected above machine against the following guidelines and that we confirm compliance with these standards Guidelines 2006 42 CE 17 05 2016 2000 14 CE 08 05 2000 Standards EN 12100 2010 EN 13862 2001 A1 2009 Tyrolit Hydrostress AG Witzbergstrasse 18 CH 8330 Pfäffikon ZH Pfäffikon 07 06 2017 P Schmid Head of Research and Development ...