TYROLIT
Hydrostress AG
Page 10
Wall saw DZ-S2
Servicing and maintenance
Lubricate lock unit
1 Grease nipple
11
4
Maintenance and servicing table
Bef
or
e e
ver
y
commissioning
A
t end of w
or
k
W
eek
ly
Year
ly
A
ft
er faults
A
ft
er damage
Wall saw
Retighten loose bolts, screws and nuts
(refer to the tightening torque speci-
fications)
X
X
X
Prism guides
Check for wear
X
Replace before the anchoring screws
of the guide prisms touch the rail or
the chassis touches the rail
X
Y-guides
Apply 2-3 applications of grease to
the lubricating nipples
X
Couplings
Check for leak-tightness and damage
and replace as required
X
Swivel arm
Clean with water
X
Check the saw blade uptake for wear
X
X
X
Feed motor
Check cleanliness and leak-tightness
X
X
X
X
Drive motor
Check cleanliness and leak-tightness
X
X
X
X
Water economy
Check water line for cleanliness and
leak-tightness
X
X
X
Blow out water
X
Saw blade
Clean with water
X
Check for wear
X
X
X
X
Service
To be performed by TYROLIT Hydros-
tress AG or an authorised workshop
After 100 / 300 / 500 / 700 hours
4.1