/ DME20PU
Power supply
INFORMATION
• The power supply must correspond with the information on the type plate.
• Protect the connecting cables from heat, oil and sharp edges.
• Do not use connecting cables for unsuitable purposes.
• Never carry the electrical tool using the connecting cable.
• Do not use the connecting cable to pull the plug out of the socket.
• In the event of power failure: switch of electrical tool, pull out the plug.
Extension cable
• Only use approved and appropriately marked extension cables outdoors.
• Extension cables with multiple sockets and simultaneous use of multiple devices must be avoided.
Always use an extension cable that is approved for the usage area with a sufficient
cross-section.
Do not use an extension cable with a conductor cross section of 1.25mm² and 16 AWG.
Recommended minimum cross-sections and maximum cable lengths
Cross section mm²
1.5
2.0
2.5
3.5
4.0
110 V
not
permitted
not
permitted
not
permitted
20 m
20 m
220 V-240 V
20 m
-
40 m
50 m
60 m