background image

Doc

 

No.

 

FM0599

 

issue

 

C

 

Page

 

1

  

169MHz

 

Telecare

 

Devices

  

PIR

 

Movement

 

Detector

  

 

__________________________________________________________________________________________________________

 

 

 

 

 

 

 

 

 

 

 

Passive

 

infrared

 

detector

 

 

Walk

 

test

 

LED

 

(disabled

 

during

 

normal

 

operation)

 

 

Alarm

 

interval:

 

1

 

or

 

3

 

minutes

 

 

User

 

replaceable

 

AA

 

Lithium

 

batteries

 

 

Low

 

battery

 

warning

 

 

Dimensions:

 

121mm

 

x

 

71mm

 

x

 

55mm

 

(HxWxD)

 

 

Weight:

 

135

 

grams

 

 

Tynetec

 

Part

 

No.

 

ZXT475

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

What

 

can

 

the

 

PIR

 

Movement

 

Detector

 

be

 

used

 

for?

 

 

The

 

PIR

 

detector

 

can

 

be

 

used

 

for

 

2

 

different

 

applications;

 

Intruder

 

Monitoring

 

 

if

 

movement

 

is

 

detected

 

an

 

alarm

 

is

 

reported

  

Inactivity

 

Monitoring

 

 

if

 

no

 

movement

 

is

 

detected

 

within

 

a

 

preset

 

period

 

an

 

alarm

 

is

 

reported

 

 

 

Recommended

 

Location

 

 

The

 

PIR

 

should

 

be

 

wall

 

mounted

 

at

 

high

 

level

 

(2.1m)

 

in

 

the

 

hallway

 

to

 

monitor

 

movement

 

between

 

rooms.

  

If

 

there

 

are

 

pets

 

in

 

the

 

home

 

the

 

PIR

 

should

 

be

 

inverted

 

and

 

fitted

 

at

 

low

 

level

 

(1m)

 

 

see

 

PET

 

ALLEY

 

mode.

 

To

 

avoid

 

false

 

alarms

 

there

 

should

 

be

 

no

 

moving

 

objects

 

or

 

rapid

 

temperature

 

changes

 

(heating

 

ducts)

 

in

 

the

 

detection

 

area.

 

 

 

Typical

 

Tools

 

Required

 

 

Be

 

careful

 

when

 

using

 

step

 

ladders

 

 

always

 

face

 

the

 

direction

 

you

 

are

 

working.

  

A

 

drill

 

is

 

not

 

required

 

if

 

the

 

self

 

adhesive

 

fixing

 

pad

 

is

 

used.

 

Always

 

make

 

sure

 

the

 

correct

 

drill

 

bits

 

and

 

screwdrivers

 

are

 

used.

 

 
 

Installation

 

 

Using

 

Screw

 

Fixings

 

 

1.

 

Undo

 

SCREW

 

A

 

from

 

the

 

bottom

 

of

 

the

 

detector

 

and

 

remove

 

the

   

          

UP

 

complete

 

lid

 

assembly.

  

 

2.

 

Drill

out

 

the

 

2

 

most

 

suitable

 

FIXING

 

HOLES

 

B

 

inside

 

the

 

rear

 

section.

  

Use

 

this

 

as

 

a

 

template

 

to

 

mark

 

the

 

wall.

 

 

 

 

 

 

3.

 

Before

 

drilling

 

the

 

wall

 

be

 

sure

 

there

 

are

 

no

 

electrical

 

cables

 

 

     

NORMAL

 

or

 

plumbing

 

under

 

the

 

surface.

  

 

 

 

 

 

ORIENTATION

 

 

4.

 

Use

 

the

 

screws

 

&

 

plugs

 

provided

 

to

 

fix

 

the

 

rear

 

section

 

to

 

the

 

wall

 

 

 

 

 

   

SCREW

 

A

 

noting

 

the

 

correct

 

orientation

 

(see

 

next

 

page

 

for

 

PET

 

ALLEY).

   

 

 

 

 

 

 

5.

 

Remove

 

the

 

insulating

 

tab

 

to

 

connect

 

the

 

batteries,

  

refit

 

the

 

lid

 

and

 

tighten

 

the

 

screw.

  

 

 

 

          

FIXING

 

HOLES

 

“B”

 

 

    

B

 

 

 

Installation

 

 

Using

 

Self

 

Adhesive

 

Pads

  

 

 

 

  

B

 

 

      

B

     

 

Undo

 

SCREW

 

A

 

and

 

remove

 

the

 

lid

 

assembly.

  

Remove

 

the

 

insulating

 

tab

 

to

 

connect

 

the

 

batteries.

   

 

 

 

     

B

 

 

    

B

     

Refit

 

the

 

lid

 

and

 

tighten

 

the

 

screw.

 

Select

 

the

 

best

 

location

 

where

 

the

 

wall

 

surface

 

is

 

clean,

 

dry

 

and

 

even.

 

Stick

 

the

 

adhesive

 

pad

 

to

 

the

 

rear

 

of

 

the

 

detector.

 

Press

 

the

 

detector

 

firmly

 

against

 

the

 

wall

 

ensuring

 

it

 

is

 

stuck

 

securely.

  

 

 
 
 

Tynetec,

 

a

 

business

 

unit

 

of

 

Legrand

 

Electric

 

Ltd

Unit

 

10

 

Cowley

 

Road,

 

Blyth

 

Riverside

 

Business

 

Park,

 

Blyth

 

Northumberland,

 

NE24

 

5TF.

 

Tel:

 

01670

 

352

 

371

 

Fax:

 

01670

 

362

 

807

 

Email:

 

[email protected]

  

Web

:

 

www.tynetec.co.uk