![Tynetec ZXT427 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/tynetec/zxt427/zxt427_manual_1186939006.webp)
Doc
No.
FM0471
issue
F
Page
6
Registering
a
Gas
&
CO
Detector
onto
a
Touchsafe
Pro
Nursecall
system
1.
Put
the
Touchsafe
Pro
Master
Panel
into
Telecare
registration
mode;
touch
the
screen
and
Logon
as
an
Engineer
or
a
Manager
(password
required),
then
from
the
main
menu
page
touch
the
Telecare
button
to
open
the
screen
shown
below…
2.
Enter
the
gas
and
CO
detector
ID’s…
3.
Press
the
Close
button
to
exit
Telecare
mode
and
the
Nursecall
panel
is
now
back
in
normal
operating
mode.
4.
Activate
both
gas
and
CO
test
calls
and
check
they
are
displayed
on
the
Nursecall
panel
like
this…
The
screen
banner
is
red
for
a
gas
and
CO
alarm
call
(
Touch
the
banner
to
display
notes
).
A
gas
or
CO
alarm
call
cannot
be
accepted
or
silenced
from
the
screen.
You
must
visit
the
appropriate
Nursecall
Call
Point
to
cancel
the
call.
Deleting
a
Gas
&
CO
Detector
from
a
Touchsafe
Pro
Nursecall
system
Select
the
gas
detector
ID
to
be
deleted
from
the
Delete
Telecare
Device
pull
‐
down
list
box
(prefixed
“T44”).
Details
of
the
gas
detector
selected
will
be
displayed
in
the
Room
,
House
Code
and
ID
boxes
below.
If
the
details
shown
are
correct
press
the
Delete
button.
Select
the
CO
detector
ID
to
be
deleted
from
the
Delete
Telecare
Device
pull
‐
down
list
box
(prefixed
“T49”)
and
repeat
as
above.
Press
the
Close
button
to
exit.
Refer
to
the
Touchsafe
Pro
Display
Panel
user
guide
(Doc
No.
FM5505)
provided
with
the
Nursecall
system
for
more
information.
Tynetec
and
Aidcall
operate
a
policy
of
continuous
improvement
and
reserve
the
right
to
change
product
specifications
without
notice.
If
any
variation
to
the
details
contained
in
this
document
are
suspected
please
contact
Tynetec’s
customer
support
dept
on
01670
352371.
Both
8
digit
ID’s
are
printed
on
a
label
on
the
rear
of
the
gas
&
CO
detector.
Note:
the
ID’s
will
always
start
with
44
xxxxxx
(gas)
and
49
xxxxxx
(CO).
Touch
the
Add
Telecare
Device
box
then
use
the
on
‐
screen
keypad
to
enter
the
gas
ID.
Hint:
enter
a
zone
in
the
Filter
box
to
narrow
the
search
for
the
room
(see
below).
Select
the
users
Call
Point
ID
from
the
Room
pull
‐
down
list
box
then
press
Save
.
Note:
this
is
the
room
unit
that
will
be
will
be
used
to
cancel
the
call.
Touch
the
Add
Telecare
Device
box
again
and
repeat
as
above
for
the
CO
ID.
Use
keypad
to
enter
8
digit
ID’s*
here
Select
the
relevant
Call
Point
ID
here
Save
when
done
Close
to
exit
mode
On
‐
screen
keypad
CALLING
CANCEL
HC
345
ID
001
Press
the
LIGHT
GREY
button
to
cancel
the
call
ZXT427
W66283
Ser:
10151313
ID:
44037640
ID:
49040302
EE0775
V1.01A
MC
*Note:
both
gas
and
CO
ID’s
must
be
entered;
Prefix
44
=
Gas
and
Prefix
49
=
CO