INTRODUCTION
The Advent xt printer records the time and date of all calls made/answered/cancelled on the
warden call system. All other system activity such as telephone line fault, mains fail, system reset,
etc. is also recorded.
PUSHBUTTON
The pushbutton performs several functions; click once to turn the printer on, press and hold for
paper feed when changing paper rolls or double-click to perform a self test and print the internal
settings.
LED INDICATOR
The LED indicator on the front of the printer will normally flash short green - long orange, there are
a number of other colour combinations which provide printer status information;
Battery Flat - or printer in sleep mode
No LED
Spool
Error Condition
Fast Flashing Red
Spool
Fast Charging
Fast Flashing Orange
Spool
Battery Low
Short Green - Short Red
Normal
Battery Low
Long Green - Short Red
Spool
Running on Battery
Fast Flashing Green
Normal
Running on Battery
Steady Green
Spool
Trickle Charging
Long Orange Flashing
Normal
Trickle Charging
Short Green - Long Orange
Buffer Mode
Battery Status
LED Pattern
The printer will enter Spool Mode if the paper runs out, the paper compartment flap is up or an
error has occurred. Data will be buffered for printing when the condition is rectified.
BATTERY STANDBY
If the mains supply is disconnected the LED will be steady green for a preprogrammed time until
the printer enters sleep mode. When the mains supply is restored click the pushbutton to return to
standby mode and any missed calls will be printed.
PRINT-OUT DETAILS
The print-out is designed to give as much information as possible about the status of the system
whilst using the minimum of paper. All alarm call print-outs are restricted to one line of text in the
following format:
Operating
Mode
Time
(24HR)
Date
(DDMM)
Call
Type
Channel
ID
Alarm
Prefix
Example: AL 0001 INTERCM 22/12 14:20 ON
The above example tells you an intercom alarm from flat 1 was detected at 14:20 on 22
December and the system was operating in onsite mode. See below for details of the
abbreviations used;
ALARM PREFIXES
AL
Alarm Call
SA
System Alarm
CA
Call Answered
SR
System Report
CE
Call Ended
FN
Function Start/Finish Time
CB
Call Back Start/Finish Time
(eg. FN 1000 = All Call)
CALL TYPES
INTERCM
Intercom Alarm
CO GAS
Carbon Monoxide Alarm
PENDANT
Pendant Alarm
GAS
Natural Gas Alarm
PCORD
Pullcord Alarm
FLOOD
Flood Detector Alarm
SMOKE
Smoke Alarm
LO TEMP Hypothermia Alarm
OPEN CT
Open Circuit Fault
BED OCC Bed Occupancy Alarm
AL FAULT
Intercom Fault (not responding)
CL WAND Client Wandering Alarm
INACTIV
Inactivity Alarm
PILL DS
Pill Dispenser Alarm
INTRUDR
Intruder Alarm
ENURES
Enuresis Alarm
PARKED
Intercom Parked
SYSTEM ALARMS (SA)
4797 BT FLT
Telephone Line Fault
3999 FIRE AL Fire Alarm Activated
4796 BT OK
Telephone Line Restored
4800 NTR FLT Network Receiver Fault (ID 800-815)
4799 MAIN FL
Mains Failed
4816 NEI FLT Network PBX I/F Fault (ID 816-823)
4798 MAIN OK
Mains Restored
4824 NKS FLT Network Keyswitch Fault (ID 824-827)
4793 LOW BT
Low Battery
4794 FUSE BL
Low Voltage Fuse Blown
SYSTEM REPORTS (SR)
CARE CL
Extracare Call Cancelled
DIAL TELE 01 Dial Telephone Number 01
SYSTEM RESET System Reset
BT LINE DROP Telephone Line Dropped
RING DETECT
Telephone Line Ring Detected
BT LINE SEIZ
Telephone Line Seized
SUB PRIVACY Intercoms with Privacy On
OPERATING MODES
ON
Onsite Mode
LO
Local Offsite Mode
RO
Remote Offsite Mode
DOOR ENTRY
DE 0032 DOOR 01
Flat 32 Called From Door Panel 1
DE DOOR OPEN 01
Door Entry Opened Door 1
TEL TRANS EN 0001 TO 0002 Flat 1 Door Entry Telephone Calls Transferred to Flat 2
TEL TRANS EN 0001
Confirm Flat 1 Door Entry Telephone Calls are Transferred
CALL TRANS EN 0008
24 Hour Calling Enabled for Flat 8
CALL TRANS DIS 0008
24 Hour Calling Disabled for Flat 8
TEL PRIVACY 0015
Flat 15 Door Entry Telephone has Privacy ON
TEL FAULT 0020
Flat 20 Door Entry Telephone has a Fault
Note: to conserve paper all door entry related print-outs can be disabled via the Advent xt “Door Entry Setup” webpage.