9.

 

VIEW

 

SYSTEM

 

LOG

 

 

Details

 

of

 

the

 

last

 

128

 

alarm

 

calls

 

are

 

stored

 

in

 

memory.

 

From

 

the

 

Main

 

Menu

 

display

 

scroll

 

down

 

to

 

 

System Log

 

 

and

 

press

 

the

 

ENTER

 

key.

 

 

Main Menu              V1.00A     

 

 

Radio Devices 

 

 

Audio Setup 

 

 

System Log 

 

 

The

 

display

 

will

 

show

 

details

 

of

 

the

 

last

 

alarm

 

call,

 

see

 

example

 

below;

 

 

System Log   004            Exit   

 

 

Smoke Alarm 

 

 

Room 000010 

 

 

Hallway 

 

 

Use

 

the

 

 

 

keys

 

to

 

scroll

 

back/forward

 

to

 

view

 

previous

 

alarms.

 

Press

 

the

 

 

key

 

to

 

exit

 

the

 

mode.

 

 

 

 

10.

 

LOAD

 

DEFAULTS

 

 

From

 

the

 

Main

 

Menu

 

display

 

scroll

 

down

 

to

 

 

Load Defaults

 

 

and

 

press

 

the

 

ENTER

 

key.

 

 

Main Menu              V1.00A     

 

 

Load Defaults 

 

 

Create Sensor 

 

 

Exit 

 

 

The

 

display

 

will

 

show

 

the

  

Load

 

Defaults

 

options;

 

 

Load Defaults                          

 

 

System Defaults 

X

 

 

 

Radio Defaults

 

X

 

 

 

Log Defaults 

X

 

 

 

Scroll

 

down

 

past

 

 

Log Defaults

 

 

and

 

the

 

display

 

will

 

change

 

to;

 

 

Load Defaults                          

  

 

 

Sensor Defaults 

X

 

 

 

Power Off

 

X

 

 

 

Apply 

 

 

 

Select

 

the

 

“Defaults”

 

you

 

want

 

to

 

load

 

then

 

press

 

the

 

 

 

keys

 

to

 

set

 

on

 

 

or

 

off

 

X

”.

 

 

 

System Defaults

 

 

clears

 

all

 

programming

 

from

 

memory

 

 

Radio Defaults

 

 

clears

 

all

 

radio

 

devices

 

from

 

memory

 

 

Log Defaults

 

 

clears

 

all

 

alarm

 

call

 

history

 

from

 

memory

 

 

Sensor Defaults

 

 

clears

 

all

 

custom

 

sensors

 

from

 

memory

  

(see

 

section

 

13)

 

 

Power Off

 

   

Turns

 

the

 

Altec

 

Response

 

unit

 

off

  

(see

 

section

 

12)

 

 

Multiple

 

defaults

 

can

 

chosen

 

with

 

a

 

 

and

 

applied

 

simultaneously.

 

Press

 

the

 

 

key

 

to

 

select

 

 

Apply

 

 

then

 

press

 

the

 

ENTER

 

key.

 

This

 

will

 

also

 

exit

 

the

 

menu.

 

 

 

Содержание Altec Response

Страница 1: ...tinual product improvement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Tynetec s Technical Support...

Страница 2: ...eck cord wrist strap belt clip ZXT406 ZXT606 Fall Detector ZXT410 Smoke Detector ZXT420 Heat Detector ZXT421 Carbon Monoxide Detector ZXT422 Gas Detector ZXT423 Flood Detector ZXT424 ZXT428 PIR Moveme...

Страница 3: ...r connecting additional devices such as a flashing light 6 The flexible black AERIAL receives signals from the Telecare sensors and must not be cut down in length or coiled up 2 HOW TO SWITCH THE ALTE...

Страница 4: ...er sub menu or give you the option to edit data or text In edit mode the right hand side arrow will move in as shown below Add Edit Device Slot 01 ID 20044216 Exit Use the keys to select the first dig...

Страница 5: ...54 Ground Floor 03 Hallway Up 16 Dining Area 29 Front Door 2 42 Lift 1 55 Bin Store 04 Stairs 1 17 Bathroom 1 30 Rear Door 1 43 Lift 2 56 Boiler Room 05 Stairs 2 18 Bathroom 2 31 Rear Door 2 44 Lift...

Страница 6: ...tered manually using this mode If a device has been lost and you need to remove it from memory you should also use this mode From the Main Menu display select Radio Devices and press the ENTER key Pre...

Страница 7: ...3 at the current volume level Use the keys to increase decrease the speech volume level Press the ENTER key again to check the new level Press the key to select Siren and press the ENTER key the sire...

Страница 8: ...oad Defaults Create Sensor Exit The display will show the Load Defaults options Load Defaults System Defaults X Radio Defaults X Log Defaults X Scroll down past Log Defaults and the display will chang...

Страница 9: ...the other calls The calls can be cleared in any order 12 LOW BATTERY WARNINGS If the Altec Response is being used on battery and its charge is running low the unit will beep and announce Low Battery...

Страница 10: ...elect Reject then try again Amend the necessary details as described in section 4 of this manual To exit the mode press the key to select Exit then press the ENTER key 14 HOW TO SWITCH THE ALTEC RESPO...

Страница 11: ...the keys to move between characters Press the ENTER key when done Press the key to select BS Code 00 then press the ENTER key Use the keys to select the first digit 0 9 of the BS code and use the key...

Страница 12: ...4 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Tynetec a business unit of Legrand Electric Ltd Unit 10 Cowley Road Blyth Riverside Business Park Blyth Northumber...

Отзывы: