2008
27
600OPTRS
3.
Water Pump
- The heart of the standard TYMCO water system is an electric pump
capable of 5 GPM. The system relief valve is set at 25 PSI.
4.
Spray Nozzles
- The operator is responsible for keeping the spray nozzle tips clean
and spraying.
ATTENTION:
On the Model 600 it is important to use only the correct output
spray tips in order to realize proper water system spray time
and pressure.
a. If a spray nozzle is clogged, the entire tip assembly must be removed for clean-
ing. To clean tip, use the edge of a knife or razor to clear tip spray slot. Then
grasp the tip between the index finger and thumb with slotted side facing up and
strike the tip sharply against a clean, hard surface to dislodge blockage.
DO NOT USE DRILL TO MAKE ORIFICE LARGER!
b. To re-install tip, insert tip into cap and hand tighten cap to nozzle assembly. Hold
tip in desired position with the use of pliers in one hand. With the other hand, use
wrench to tighten cap which locks tip position.
C. WINTERIZATION
To winterize the Model 600 water system, the system should be filled with solution of
propylene glycol. Follow procedures outlined below:
1. Disconnect siphon hose from water tank.
2. Submerge hose end into container of propylene glycol.
3. Start auxiliary engine and run at idle. Turn water switch on until propylene glycol
is observed to spray from nozzles. Turn water switch off.
4. Drain water tank.
5. System is now winterized.
WATER SYSTEM SERVICE AREAS
(M00768)
Содержание 600 2008
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 13: ...2008 3 600OPTRS...
Страница 19: ...2008 9 600OPTRS...
Страница 23: ...2008 13 600OPTRS...
Страница 32: ...600OPTRS 22 2008...
Страница 33: ...2008 23 600OPTRS M00771 MODEL 600 SKID PLATE SETTING...
Страница 34: ...600OPTRS 24 2008 MODEL 600 SPRING SETTING...
Страница 42: ......