The temperature cut-out
The temperature cut-out in the heater has the purpose of pro-
tecting the components, tubular elements and woodwork in the
sauna from overheating. If the temperature cut-out is activated,
the power supply to the control panel will be cut off . Once the
temperature in the sauna cools down, it may be reset. The cause
of the overheating must be established before resetting the tem-
perature cut-out. To reset it, press the red button under the heater
(see Fig. 6).
Figure 6: Resetting the temperature cut-out
Symptom
Possible cause
Remedy
The heater is not
working.
The main power
switch is off .
Switch the main
power switch on.
The heater is not
working.
Fuses in the distri-
bution board have
blown/tripped.
Replace/reset the
fuses in the distri-
bution board that
have blown/tripped.
The heater is not
working.
The internal tempe-
rature cut-out has
been activated.
For more informa-
tion, see the Tem-
perature cut-out
section.
Check and fi x
the cause of the
temperature cut-out
activation.
If you are unsure
why the tempera-
ture cut-out was
activated, contact a
professional.
The fuses/ground
fault interrupt devi-
ce in the distribu-
tion board trip as
soon as the heater
is turned on or
during operation.
The heater has not
been used for a
long period, cau-
sing an insulation
fault in the pipe
elements.
Switch off the
heater and do not
use it. Contact a
professional for
an inspection, or
contact the dealer
during the guaran-
tee period.
TROUBLESHOOTING
Troubleshooting the sauna heater
Table 1: Troubleshooting the sauna heater