![Tylo H2 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/tylo/h2/h2_installation-and-user-manual_1186672017.webp)
6
Model Power
kW
Sauna heaters
connection cable
H07RN-F /
60245 IEC 66
mm
2
400 – 415V 3N~
2 – Group effect
Fuse
A
Sauna heaters
connection cable
H07RN-F /
60245 IEC 66
mm
2
230V 3~
2 – Group effect
Fuse
A
SK-181 (1101 -181) 18 (9 + 9)
2 x (5 x 2,5)
2 x (3 x 16)
2 x (4 x 6)
2 x (3 x 25)
SK-210 (1101 -210)
21 (9 +
12)
5 x 2,5
5 x 6
3 x 16
3 x 20
4 x 6
4 x 10
3 x 25
3 x 35
SK-260 (1101 -260) 26 (13+13)
2 x (5 x 6)
2 x (3 x 25)
------
------
Table 1 Connection cable and fuses
3.4 Electric heating toggle
The electric heating toggle applies to homes with an electric heating system.
The contactor case has a connection (marked 55) for controlling the electric heating toggle.
Connector 55 and the heating elements are simultaneously live (230V). Refer to the contactor case operating ma-
nual for more specific instructions.
Image. 2 Location for the connection box
3.5 Locating the connecting box for the connection cable in the sauna room
A = Specified minimum safety clearance, see table 2 side 7.
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The
connection box must be clear of obstacles. When installing the connection box to zones 2 or 3,
refer to the instructions and regulations of the local energy supplier.
200
m
m
A
A
3.
2.
1.
50
0 m
m
50
0 m
m