background image

TYKOFLEX AB, P.O. Box 614, SE-135 26 Tyresö, Sweden, Phone: +46 8 505 949 00, 

Fax +46 8 742 30 01 [email protected], www.tykoflex.com

KOMPLETTA ARMATURER / COMPLETE UNITS

HINDERLJUS / OBSTRUCTION LIGHT RL30 LED/IR 24/48 VDC & 230 VAC

11990310 11990300 11990320

FÖR UTBYTE / LIGHT EXCHANGE UNIT:

 

LED/IR-ENHET / UNIT RL30 24/230V  11990305

 

LED/IR-ENHET / UNIT RL30 48V 

11990307

Manual RL30

M

ANU

AL HINDERL

JUS / OBSTRUC

TION LIGHT RL30

 T

Y

K

OFLEX

R

ev

. 220328

Содержание RL30

Страница 1: ...TTA ARMATURER COMPLETE UNITS HINDERLJUS OBSTRUCTION LIGHT RL30 LED IR 24 48 VDC 230 VAC 11990310 11990300 11990320 FÖR UTBYTE LIGHT EXCHANGE UNIT LED IR ENHET UNIT RL30 24 230V 11990305 LED IR ENHET UNIT RL30 48V 11990307 Manual RL30 M A N UA L H I N D E R L J U S O B S T R U C T I O N L I G H T R L 3 0 T Y K O F L E X Rev 220328 ...

Страница 2: ...slutning av 5 Ledad stigar kabel Connection of 5 stranded installation cable 2st Gula larmkablar från LED Enheten 2 yellow signal cables alarm from LED unit Cirka 10 mm Mantelinstick Insert the installation cable approx 10 mm inside the housing 5 Ledad stigar kabel Skala kabelmanteln cirka 120 mm Skala ledarna cirka 10mm 5 stranded installation cable Remove outer insualtion approx 120 mm and cable...

Страница 3: ...x 46 8 742 30 01 info tykoflex se www tykoflex com Anslutning av 5 Ledad stigar kabel till plint Connection of 5 stranded installation cable to terminal block Leveransutförande Scope of delivery 2st Gula larmkablar från LED Enheten 2 yellow signal cables alarm from LED unit ...

Страница 4: ... Anslutning av 5 Ledad stigar kabel Connection of 5 stranded installation cable 10 mm 110 mm 10 mm 2st Gula larmkablar från LED Enheten 2 yellow signal cables alarm from LED unit 5 Ledad stigar kabel Skala kabelmanteln cirka 120 mm Skala ledarna cirka 10mm 5 stranded installation cable Remove outer insualtion approx 120 mm and cable insulation 10 mm Cirka 10 mm Mantelinstick Insert the installatio...

Страница 5: ...49 00 Fax 46 8 742 30 01 info tykoflex se www tykoflex com Röd LED Red LED IR 2st Gula larmkablar från LED Enheten 2 yellow signal cables alarm from LED unit Anslutning av 5 Ledad stigar kabel till plint Connection of 5 stranded installation cable to terminal block ...

Страница 6: ...ablarna För koppling till larmmottagare ENGLISH 1 Remove the outer coil from the black electric cable for approx 3 cm Non polarized 2 Disconnect the lamp socket by unscrewing two screws from the housing and the belonging cables from the terminal block Proceed to assemble the LED IR unit by connecting the cables to the terminal block 3 NOTE Do not use mineral oils solvent or grease on the plastic c...

Страница 7: ... tranformator ingår även nedan komponenter For use with transformer supplied components 51991025 x1 70902229 x2 11991055 x1 51991090 x1 71991280 120 x1 71991255 x1 51991012 x1 70902818 x2 71400325 x1 71991104 x1 24 230V 71991106 x1 48V 71991270 x1 71991027 x1 71991175 300mm x1 230V 71991175 200mm x1 24 48V 70902325 x1 71991260 x1 71991290 x1 230V 71991290 x0 5 24 48V 71991210 x1 70902810 x1 719912...

Страница 8: ...al The device must be installed and checked by trained personnel Hinderljus RL30 skall endast användas tilländamålet flyghinderljus Annan användning än hinderljus ses som felaktigt användningsområde och klassas därför som felaktigt installerad enhet Tykoflex AB ansvarar ej för felaktigt utförda installationer The RL 30 obstruction light must only be used for the purpose of its design Any other use...