Under Counter Extreme
26
27
Operation Touch Screen
How to use Cleaning Filter
How to use Cleaning Filter
Operation Touch Screen
%
50
%
50
Display line of the set
status
Functional water operation
standby mode
Display line of filter usage
( default : 00% )
Alkaline level 1
Alkaline level 2
Alkaline level 3
Purified water
Turbo water
Acidic level 1
Acidic level 2
Acidic level 3
Icon : description
Set up
Voice on
Voice off
Cleaning
Eco mode on
Eco mode off
Filter 1 usage
Filter 2 usage
1
To prevent any trouble caused by scale build-up in the Electrode
and the water ionizer's internal water piping, please perform a
Citric acid cleaning with a Citric acid filter regularly.
User negligence in regards to hard water is not covered under
warranty.
※
TYENT WATER IONIZER CLEANING FILTER is a disposable filter.
When cleaning the machine with a
TYENT CLEANING FILTER
, be
sure to always use the H2O purified water level only, do not use any
other level while cleaning or damage could occur.
If the unit was subject to hard water conditions, an Anti-Scale filter
should be connected. This filter will prevent scale build-up on plates.
Attention
Remove the existing 2nd filter and install the TYENT Cleaning Filter.
※
Connection: clockwise / Separation: counter-clockwise
※
Caution: Do not remove the 1st filter when performing
a cleaning.
Run the unit on the H
2
O cycle only for
30seconds
and stop.
Leave the machine sit for 3 hours and don’t use.
After 3 hours
,
remove the TYENT Cleaning Filter and install the 2nd filer.
Run the unit on the H2O cycle for
5 minutes
to wash the inside of the
ionizer and the filter with clean water.
Please check the pH levels of the machine. The flow rate and the pH
levels should return to normal. If not, repeat steps
①
through
⑤
①
②
③
④
⑤
⑥
2nd
Filter
2nd
Filter
5min
30sec
※
※