background image

 

Specifications: 

6.  When using outdoors, the battery chargers must be inside 

a weatherproof enclosure. 

7.  The battery charger LED will be red when charging and will 

turn green when battery is fully charged. 

8.  Battery chargers can be used to charge any sealed lead 

acid battery.  

 

 

 

 

 

TP-BC12

-

120

 

TP-BC24

-

120

 

TP-BC48

-

120

 

Total Power Available (for 

Load and Battery charging)

 

120W

 

120W

 

120W

 

Nominal Battery Voltage

 

12VDC

 

24VDC

 

48VDC

 

Battery Charge Max Current

 

8.3A

 

4.35A

 

2.15A

 

Battery Charger Voltage

 

14.4V

 

28.8V

 

57.6V

 

Load Regulation

 

5%

 

Line Regulation

 

3%

 

Efficiency

 

85% Minimum

 

Output Connector

 

2 Wire  ;  914mm (36”) long cable

 

EMC Standards

 

FCC Class B , NE55022 Class B

 

Safety Standards

 

UL60950-1, CSA 22.2, TUV EN60950

 

AC Power Input (+-10%)

 

120VAC / 240VAC , 50/60Hz

 

AC Input Current

 

2.5A Max

 

HiPot Test

 

3000VAC

 

Insulation Resistance

 

50 MOhm, 500VDC

 

Operating Temperature

 

-

30 to +55C (22 to +131°F)

 

Operating Humidity 

(RH)

 

Up to 90% (non condensing)

 

Storage Temperature

 

-

40 to +85°C  (-40 to +185°F)

 

Storage Humidity

 

Up to 90% (non-condensing)

 

MTBF 

(Mean Time Between Failure)

 

>50,000 hrs

 

Dimensions 

(LxWxH)

 

172 x 72.5 x 34.5mm ( 6.8 x 2.9 x 1.4”)

 

Weight

 

439g (15.5oz)

 

Warranty

 

3 Years

 

Содержание TP-BC12-120

Страница 1: ...ake a moment to review this guide before instal lation Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Make sure there are no people pets etc below when you are working on a roof or ladder ...

Страница 2: ...nel to more closely manage the battery charging 3 The battery charger can be connected to the solar input of the solar charge controller in parallel with a solar panel to provide a dual power solution 4 The battery chargers can be connected to the solar input of a Tycon PWM or MPPT solar charge controller 5 The battery chargers have a 2 wire output for ease of con nection Typical Application with ...

Страница 3: ... Battery Charger Voltage 14 4V 28 8V 57 6V Load Regulation 5 Line Regulation 3 Efficiency 85 Minimum Output Connector 2 Wire 914mm 36 long cable EMC Standards FCC Class B NE55022 Class B Safety Standards UL60950 1 CSA 22 2 TUV EN60950 AC Power Input 10 120VAC 240VAC 50 60Hz AC Input Current 2 5A Max HiPot Test 3000VAC Insulation Resistance 50 MOhm 500VDC Operating Temperature 30 to 55C 22 to 131 F...

Страница 4: ...es not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage for units that were not mounted according to user manual Usage other than in accordance with instructions and the normal intended use...

Отзывы: