SPECIFICATIONS             

Subject to change without notice

 

 

 

TPDIN-SC48-20 

Controller Type

 

MPPT 

Solar Input Voltage

 

62VDC to 85VDC 

Solar Input Current

 

20A Maximum 

Battery Voltage

 

48VDC 

Fuse Type

 

58V Fast Blo Auto Blade 

Type (Littlefuse 

142.6185.5206) 

Low Voltage Disconnect

 

45.8V to 47.8V 

Low Voltage Disconnect recovery

 

48.1V to 49.2V 

Battery Type

 

GEL or AGM 

External DC Input 

 

62V to 75VDC, 3A 

External DC Input Connector

 

4p mini DIN 

PoE Switch 

Qty 7 10/100/1000Mb 

PoE Output Power 

(Numbers shown are 

for 48V PoE. Divide by 2 for 24V PoE)

 

Port 1-3 35W Passive PoE+ 

Port 4-7 18W Passive PoE 

Port Surge Protection

 

15KV 

Auxiliary Output

 

3A Max 

Measurement Accuracy (V / I / T)

 

+/-0.1V, +/- 0.1A, +/- 1Deg 

Power Consumption 

 

3W typ 

Data Logger 

 

FIFO, 15,000 records 

Wire Size

 

8AWG Solar/Batt 

12AWG Aux Output 

Operating Temperature

 

-40C to +65C 

-40F to +149F 

Operating  Humidity

 

0% to 90% 

Warranty

 

2 Years 

Содержание TPDIN-SC48-20

Страница 1: ...y Features Industrial Strength Manageable 24VDC or 48VDC Output 7 Gigabit Passive PoE ports 48V 20A MPPT So lar Automated Alerts Removable Connections Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Ma...

Страница 2: ... off until the settings are changed in the web user interface STEP 5 If you will be using the Aux Output connect your load wires to the Small Green 2 Pin Connector Be sure the wire connections are tight Be sure the voltage polarity is correct Plug the Aux connector into the Aux Output socket If you won t be using the Aux Output just plug the empty connector back into the socket STEP 6 Connect Ther...

Страница 3: ...ile options and set IP address options Load Power Enable or disable all power to the loads This disa bles all output power and overrides all other port power settings Save Port Names Customize names for each port like CAM1 WIFI PUMP FAN BHAUL etc There is a 6 character limit Set Port Startup States Set each ports default startup state OFF 24Vor 48V This is the state the port will revert to after a...

Страница 4: ... Power Off and Power On Volts When the battery voltage falls below the Power Off voltage the load is turned off and when it rises above the Power On voltage the load is turned back on We recommend using the default values Set temperature default as deg F or C Network Settings Set IP Address to DHCP or Static Set Host Name The host name will show in the discovery tool and the browser tab This can h...

Страница 5: ...P 11 The Monitor Page is the main status and port control page Port voltage can be changed and ports can be turned On or Off manually or they can be cycled Battery Voltage Shows the present battery voltage Battery Current Shows current flowing into or out of the battery A positive current means the battery is charging A negative current means the battery is discharging Input Voltage Shows the sola...

Страница 6: ...Maximum Battery Voltage 48VDC Fuse Type 58V Fast Blo Auto Blade Type Littlefuse 142 6185 5206 Low Voltage Disconnect 45 8V to 47 8V Low Voltage Disconnect recovery 48 1V to 49 2V Battery Type GEL or AGM External DC Input 62V to 75VDC 3A External DC Input Connector 4p mini DIN PoE Switch Qty 7 10 100 1000Mb PoE Output Power Numbers shown are for 48V PoE Divide by 2 for 24V PoE Port 1 3 35W Passive ...

Страница 7: ...nput won t be used unless there is no sun UPS non solar Operation The unit can also be used as a high powered UPS or battery backup system by providing 65VDC 18A into the PV and inputs Tycon offers a AC to DC power supply to ac complish this SNMP The controller can be accessed via HTTP or SNMP SNMP enables remote management via an SNMP control server MIB file can be found at http tyconsystems com ...

Страница 8: ...s supplied with a limited 24 month warranty which covers material and workmanship defects This warranty does not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage Usage other than in accorda...

Отзывы: