User’s Manual
TYCON TP-SW5G-MULTI
TYCON POWER SYSTEMS
4
*PoE LED (the left indicator on RJ45)
P1~P4
PoE
Yellow
Delivering power on this port.
Off
No power is delivering on this port.
*Power wiring
The TP-SW5G-MULTI allow the four various input voltage range from 12V to 57VDC, the terminal block
on the rear panel used for input, it should be wired as detailed below, please make sure the input current is
not over 10A.
Ports 1~4 will deliver various power over the Ethernet cable as detailed below:
Port 1:
* Data pair A on line 1 and 2
* Data pair B on line 3 and 6
* Data pair C plus VI+ on line 4 and 5
* Data pair D plus VI1- on line 7 and 8