background image

User’s Manual

                                                                           

TP-SCPOE-24XX(-HP) Series 

 
 

 

Operation Guide     
 
NOTICE: 

 

1.  Connect the battery to the BAT terminal. Make sure the polarities are 

correctly connected. Sequentially connect the solar panel to SOL terminal 
and connect POE source to PoE input (lower) jack. (If solar panel or PoE 
source is installed before the battery, and if the polarities of the battery be 
reversed, then the fuse will be burnt.) 
 

2.  Make sure the battery is properly connected to the unit. If no battery is 

connected, then the voltage at BAT terminal will be approx 27.3+0.5V 

 

3.  The solar panel cannot be used stand alone without battery connected. 

 

4.  When a solar panel and PoE input are connected to the charger, if the 

voltage of solar panel is higher than 30V, then solar panel is always the 
main power source of the charger. 

 

5.  When charge from solar panel, as the battery full and turn to floating 

stage, the CHA light will start flash. 

 

6.  When charge from PoE, as the battery full, the CHA light will be turn off, if 

the CHA is always flash, that means the input wattage lower than the 
required minimum wattage. If only charge battery, the minimum PoE input 
wattage is 94W, if full load, the minimum PoE input wattage is 160W. 

 

7.  When battery connect to BAT terminal and with valid voltage, then the 

LOA indicator will always light on even no load connected. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание TP-SCPOE-24xx Series

Страница 1: ...TYCON POWER SYSTEMS TYCON TP SCPOE 24xx HP Series Solar PoE Battery Charger USER S MANUAL ...

Страница 2: ...ection Solar Panel Polarity Reverse Protection Solar Panel Over Charge Protection Output Short Circuit Protection Output Over Voltage Protection POE Output Short Circuit Protection POE Output Support 802 3af Function TP SCPOE 2448D HP Two Input method 1 Solar Panel 2 PoE Power Source Always Solar First Up to Three Outputs DIN Rail Mountable ...

Страница 3: ...erse indicator the LED lights when the battery polarities are reversed detail description see Sec 5 1 6 IN PoE Input Jack the lower RJ45 jack used for PoE input Allowed input voltage 36 57V 7 OUT PoE Output Jack the upper RJ45 jack used for PoE output Output voltage depends on what model you selected 8 Fuse Fuse for output over current protection limiting the battery output current 10A If solar pa...

Страница 4: ...l cannot be used stand alone without battery connected 4 When a solar panel and PoE input are connected to the charger if the voltage of solar panel is higher than 30V then solar panel is always the main power source of the charger 5 When charge from solar panel as the battery full and turn to floating stage the CHA light will start flash 6 When charge from PoE as the battery full the CHA light wi...

Страница 5: ...t 24 5V 3 0Battery Charge Types A Solar Panel charge current depends on the wattage of the solar panel B POE fixed current 2 6A max TP SCPOE 2424 only 1 3A max 4 0Battery Types 24V Lead Acid Battery 5 0 Protection 5 1 Battery Polarity Reverse Protection If only battery connected to terminal when the battery polarities were reversed the model will stop output and REV indicator light on When the bat...

Страница 6: ...put Voltage Limit The output voltage on the rear terminal normally is the same as battery if the battery voltage higher than 24 5V the output voltage on the terminal will be clamped at 24 5V The PoE output of TP SCPOE 2424 HP with the same limit 6 GENERAL DESCRIPTION 6 1 Operation Temperature 20 60 Degree 6 2 Storage Temperature 40 85 Degree 6 3 Operation Humidity 5 90 6 4 Cooling Free air cooling...