User’s Manual
TP-SCPOE-24XX-HP Series
5.3 Battery Over Charge Protection:
Fuse control, over 10A, the fuse will be burnt.
5.4 Solar Panel Polarity Reverse Protection:
When solar panel polarities be reversed, the charger stop output, it won’t damage
the charger or end device
5.5 Solar Panel Over Charge Protection:
When charge current over 10A, the fuse will be burnt.
5.6 Output Short Circuit Protection:
When the rear output terminal or PoE output be short circuit, protection be active,
the product stop output and auto-recover when the connector back to normal
connection.
5.7 Battery Output Current Limit:
The fuse will be burnt when battery output current over 10A
5.8 Load Output Voltage Limit:
The output voltage on the rear terminal normally is the same as battery, if the
battery voltage higher than 24.5V, the output voltage on the terminal will be
clamped at 24.5V. The PoE output of TP-SCPOE-2424-HP with the same limit.
6. GENERAL DESCRIPTION
6.1 Operation Temperature:
-20 - +60 Degree
6.2 Storage Temperature:
-40 - +85 Degree
6.3 Operation Humidity:
5% - 90%
6.4 Cooling:
Free air cooling
6.5 SIZE
150*118*40mm (D*W*H)
7. RJ45 Connected and pin out:
RJ-45 Input (Data & Power)
RJ-45 Output (Data & Power)
Pin
Symbol
Description
Symbol
Description
1
RX+
Data Receive
RX+
Data Receive
2
RX-
Data Receive
RX-
Data Receive
3
TX+
Data Transmit
TX+
Data Transmit
4
(-Vdc)_
Feeding power(+)
(-Vdc)_
Feeding power(+)
5
(-Vdc)_
Feeding power(+)
(-Vdc)_
Feeding power(+)
6
TX-
Data Transmit
TX-
Data Transmit
7
-Vdc
Feeding power(-)
-Vdc
Feeding power(-)
8
-Vdc
Feeding power(-)
-Vdc
Feeding power(-)