3.  Other device test: Each of the other devices in the system is activated by the user and the

display indicates which devices were not yet tested. The 

it's me

 indication helps to identify

the untested devices if necessary. A counter also indicates the number of devices that remain

untested.

4.  Email test: Generates an event to be sent to the predefined private email addresses.

Replacing the PowerMaster-360 backup battery

The control panel battery is rechargeable. If a 

CPU LOW BATTERY

 trouble message is received

when the control panel is connected to AC power, and this trouble state continues for more than

a few hours, the battery may need to be replaced. Contact Technical Support or your installer for

further assistance. Do not attempt to replace the battery yourself. Only an original manufacturer

battery must be used.

Replacing batteries in wireless devices

The wireless devices supplied with your system are powered by batteries that last several years in

normal use. However, when a battery becomes weak, the device sends a low battery message to

the control panel, and a low battery trouble message is displayed along with the zone information.

The respective manuals of these sensors or devices should be consulted for proper battery

replacement guidelines to be performed by the installer.

Note: 

When the 

low battery

 message is received, the battery should be replaced within 7

days.

Acknowledging keyfob low battery

Some regulations and institutions require the user to acknowledge when the keyfob enters a low

battery condition. In such cases the installer will program the system to operate as follows: If you

try to disarm the system with a key-fob whose battery voltage is low, a protest beep will be heard

for 15 seconds. During this period press the keyfob disarm button again to disarm the system.

If you perform this action during the 15-second period, a 

Low Bat

 acknowledge message will be

stored in the event log. If the disarm button is not pressed again during the 15 seconds period you

will not be able to re-arm the system unless you perform either one of the following actions:
• Press 

away

 twice to arm the system.

• Press 

away

 and then press disarm button.

Performing either of these two actions stores the acknowledge message in the event log.

Cleaning the control panel

Clean the keypad using a lint-free cloth or soft wipes. Lightly moisten the cloth or wipes with water,

household glass-cleaning agent, or low concentration isopropyl alcohol (IPA).

WARNING:

Do not use cleaning products that contain acids, bleach or corrosive agents.

11

D-307503 PowerMaster-360 User's Guide

Содержание Visonic PowerMaster-360

Страница 1: ...S notifications 9 Operating the alarm system through SMS 10 Periodic testing 10 Replacing the PowerMaster 360 backup battery 11 Replacing batteries in wireless devices 11 Acknowledging keyfob low batt...

Страница 2: ......

Страница 3: ...private telephones and mobile phones Events can be reported by SMS and email Your installer can determine what type of events will be reported to which destination Note A qualified technician must ch...

Страница 4: ...ifferent users assigned to each partition whereby each user can arm the partition to which they are assigned Common areas The system supports areas that are used by two or more partitions Example a re...

Страница 5: ...s an abnormal condition D Server connectivity Blue a connection is active between the panel and the PowerManage server Off the panel is not connected to the PowerManage server E Smart home service con...

Страница 6: ...rovide homeowners with visual indication of successful command execution and system status Keyfobs The KF 234 PG2 and KF 235 PG2 keyfobs are used to arm and disarm the alarm system for emergency signa...

Страница 7: ...sturbance of a perimeter zone will cause an alarm Quick arm away Used to arm away without the need to provide a user code Note the installer should enable this option if required Quick arm home Used t...

Страница 8: ...the detectors Pressing the emergency buttons on the keypad When an alarm is initiated the internal control panel s sounder is activated first for a limited period set by the installer this is the abor...

Страница 9: ...ile phone numbers The messages can be tagged with a House ID name for example JOHN S HOUSE The following are examples of the reported SMS messages JOHN S HOUSE AWAY JOHN S HOUSE DISARM JOHN S HOUSE PO...

Страница 10: ...ST_ code TURN PGM ON PGM_XX_ON_ code P PGM_XX_ON_ code TURN PGM OFF PGM_XX_OFF_ code P PGM_XX_OFF_ code House ID includes up to 16 characters for example JOHN S HOUSE Note There may be some delay in e...

Страница 11: ...devices should be consulted for proper battery replacement guidelines to be performed by the installer Note When the low battery message is received the battery should be replaced within 7 days Ackno...

Страница 12: ...abled A partition is alarmed when receiving an event from an alarmed device assigned to that partition Alarmed devices do not affect partitions to which they are not assigned A siren is common to all...

Страница 13: ...household and make an evacuation plan Draw a floor plan of your home showing two ways out of each room including windows Do not forget to mark the location of every smoke detector Test all smoke detec...

Страница 14: ...escape plan It is important to be aware of the escape plan when children are permitted to attend sleepovers at friends homes If they do not have a plan in place offer to help them make one PowerMaster...

Страница 15: ...ectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to...

Страница 16: ...the Products to the original purchaser only the Buyer against defective workmanship and materials under normal use of the Products for a period of twelve 12 months from the date of shipment by the Sel...

Страница 17: ...use the Product or for loss or destruction of other property or from any other cause even if Seller has been advised of the possibility of such damage The SELLER shall have no liability for any death...

Страница 18: ...is supplied shall not apply Governing Law This disclaimer of warranties and limited warranty are governed by the domestic laws of Israel Warning The user must follow the Seller s installation and ope...

Отзывы: