2.3. Enrollment
Refer to the PowerMaster control panel's Installer Guide and follow the procedure under the
"02:ZONES/DEVICES"
option of the Installer Menu.
A general description of the procedure is provided in the following flow chart.
Step 1
Step 2
Step 3
Step 4
Enter the Installer menu and select
“02:ZONES/DEVICES”
Select "ADD NEW DEVICE"
See Note 1
Enroll the device (see Figure 5) or
enter the device ID
Select a detector number for the
new detector
02:ZONES/DEVICES
ð
ADD NEW DEVICES
6
ð
ENROLL NOW
or
ENTR ID:XXX-XXXX
ð
Z0x:Motion Sens
ID No. 130-XXXX
ð
MODIFY DEVICES
Step 5
Step 6
Step 7
Configure Location, Zone Type &
Chime parameters
Enter PARTITIONS.
See Note 2
Assign partitions to the detector by
pressing the
,
and/or
buttons on the
panel
Z0x.LOCATION
Z0x.ZONE TYPE
Z0x.SET CHIME
ð
Z0x.PARTITIONS
ð
Z0x:P1
n
--
P2 ....P3
n
ð
means scroll
ww
and select
OK
.
Notes:
[1] If the detector is already enrolled you can configure the detector parameters and assign partitions via the
“Modify Devices”
option – see Step 2.
[2] PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports the Partitioning feature (for further details, see
"Partitioning" in the PowerMaster Installer Guide).
2.4. Configuring the Detector Parameters
Enter the
DEVICE SETTINGS
menu and follow the configuration instructions for the TOWER 20 AM PG2 PIR detector as described below.
Option
Configuration Instructions
ALARM LED
Define whether or not to activate the alarm LED indication.
Optional settings: ON (default) and OFF.
PIR
SENSITIVITY
Define if the detector operates at regular or high PIR sensitivity, or that at least one detection zone must be crossed before an alarm
is triggered (One Region).
Optional settings: LOW (default), HIGH and One Region.
Note:
For EN compliance, the detector should be set to "One Region".
DISARM
ACTIVITY
Define whether or not to set the activity time during Disarm mode.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay, YES + 30s delay, YES + 1m delay, YES +
2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and YES + 60m delay.
OUTDOOR
ANTI-M
Enable or disable the outdoor anti-masking feature.
Optional settings: Disabled (default) and Enabled.
ALARM
Hours
Define whether motion alarms are always enabled or only when dark (at night).
Optional settings: Day and Night (default) and Night only.
2.5. Local Diagnostic Test
A. Set the detector in local diagnostic mode, as follows:
Open the detector’s bottom cover (see "Figure 4 – Battery Insertion" on the previous page, steps 1 - 3) and then press and release the tamper
switch (see "Figure 5. TOWER 20 AM PG2 " on the next page). The LED will flash for 60 seconds and then the detector will enter into 15 minutes'
local diagnostic mode.
Note:
Note: The detector automatically enters into 15 minutes' local diagnostic mode after battery installation or Tamper switch recovery.
B. Adjust the detector in the horizontal plane to cover the required protected area.
C. Walk into the detectors’ field of view. Adjust the vertical plane to receive the maximum number of detections when crossing the entire 90
°
pattern.
Verify that the LED blinks each time your motion is detected, as you cross one Quad PIR. Then verify that the LED lights steadily for 2 seconds as
you cross the next adjacent Quad PIR. After alarm indication, the LED blinks three times and provides the received signal strength indication (see
Table 2).
Table 2 – Received Signal Strength Indication
LED response
Reception
Green LED links
Strong
Orange LED blinks
Good
Red LED blinks
Poor
No blinks
No communication
D-304046 TOWER-20 PG2 Installation Instructions