Tyco DSC WK141 Скачать руководство пользователя страница 4

D-306041 WK141 Installation Instructions 

Panel Response 

Buzzer Indication 

LED Indication 

Problem Indication 

 

Success:

 Operation is 

successfully completed 

 

Happy (

success

) beep 

Momentary GREEN 

If the panel is 

Not-Ready

 or if a 

Trouble

 or 

Alarm 

Memory

 conditions exit, the Status button (G in Fig.1) 

flashes for few seconds. To identify the reason, press 
the button to retrieve the Status indication - refer to 
section 3.6 for further information. 

Fail:

 Operation 

failed 

 

 

Sad (

failure

) beep 

Momentary RED 

No communication:

  Control 

panel does not respond. 

None 

None

 

3.6 Retrieving and Displaying System Status 

Step 

Status Request 

User Actions 

Keypad & Panel Response 

1  

Request Status 

 

The  keypad's  LED  blinks  red  once  to  indicate  transmission  of  the  status 
request to the control panel.  

Look at status 

 

 / 

 /

 

 

The panel's status is indicated on the keypad via the LED and the Arming 
Keys and Partition Keys 

– see below 

Arming Status 

The system Arming Status is indicated via the respective 

 

 

 

arming/disarming buttons' LED

 

that light for several seconds. For example, if the system is 

armed AWAY, the 

 

button will light and if the system is disarmed, the 

 

button will also light. 

If  Partition  is  enabled,  the  arming  Status  of  the  first  partition  is  displayed  concurrently  with  the  corresponding  first  partition  button  LED

 

,

  then  the  second 

partition Status is displayed concurrently with the second partition button LED 

 

and then the third partition Status is similarly displayed. 

Indication of Ready/Not Ready & Trouble Status 

The Ready/Not Ready, Alarm Memory and Trouble indications are provided via the keypad LED (see "M" in Figure 1) as follows: 

LED Indication 

[1]

 

System Status 

[2]

 

What it Means 

Green 

System READY  

You can arm the system  

Red 

System NOT- READY  

One of the zones is not secured. You can not arm the system before the zone is secured or bypassed. [3] 

Yellow 

Trouble or Alarm Memory 

There was an alarm or there is trouble situation that need to be reviewed and cleared. [3]  

Yellow blinking 

Keypad Low-Battery 

The battery of the keypad must be replaced as shown in section 2.1.  

[1]

 

The LED indication is displayed after the first red blink indicating the status request. 

[2] If there is more than one status indication, the LED will display them consecutively. 
[3] See respective sections in the control panel's User and Installer's Guides. 

 

APPENDIX A: SPECIFICATIONS 

Frequency Band (MHz)

 

Europe and rest of world:

 433-434, 868-869 

USA:

 912-919** 

**Note:

 For UL Listed product, enable this frequency band.

 

Operating Temperature 

0

C to 49

C (32

F to 120

F) 

Dimensions (LxWxD) 

127x70x24mm (5 x 2-3/4 x 31/32 in) 

Communication Protocol

 

PowerG

 

Relative humidity

 

93% 

Battery type 
Battery Life Expectancy 

3V, CR123A type.  (GP) 
4-5 years* (for typical use). 

Weight (including 
battery)

 

107g (3.4 oz)

 

Low Battery Threshold

 

2.1 V 

Color

 

White

 

3 years+, if used with a proximity tag 

 

 

APPENDIX B: COMPLIANCE WITH STANDARDS 

 

Compliance with Standards 

 

 

 

Europe:

 EN 300220-1, EN 50130-4, EN 50131-1 Grade 2 Class II, EN 50131-3, EN 301489.

 

The WK141 is compatible with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 
and EN50131-1 Grade 2 Class II. 
Certified by Norwegian accredited certification body Applica Test & Certification AS in accordance with EN 50131-3, EN 50131-6, EN 
50131-5-3, EN 50130-4, and EN 50130-5. 
Applica T&C has certified only the 868 MHz variant of this product. 

USA: 

CFR 47 part 15. 

Canada

: RSS 210. 

RFID Tags:

 ISO-18000-2 (125 kHz) 

UK:

 This product is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and environmental class 2. DD243 

and BS8243 

The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in the technical 
brochure. This functionality has not been tested to comply with the respective technical requirements and should therefore be considered 
outside the scope of the product’s certification.

 

EN 50131-1 Security Grade 

According to EN 50131-1:2006 and A1:2009, this equipment can be applied in installed systems up to and including Security Grade 2. 

EN 50131-1 Environmental Class 

Class II 

 
This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). 
This equipment complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled environment. 

RFID Tags:

 ISO-18000-2 (125 kHz) 

Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) this device 
must accept any interference that may be received or that may cause undesired operation. 
The digital circuit of this device has been tested and found to comply  with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference  in  residential  installations.  This  equipment  generates,  uses  and  can  radiate  radio  frequency  energy 
and,  if  not  installed  and  used  in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio  and 
television reception. However, there is no guarantee that interference will not occur in a particular installation. If this 
device  does  cause  such  interference,  which  can  be  verified  by  turning  the  device  off  and  on,  the  user  is 
encouraged to eliminate the interference by one or more of the following measures:  

– Re-orient or re-locate the receiving antenna. 

– Increase the distance between the device and the receiver. 

– Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. 

– Consult the dealer or an experienced radio/TV technician. 
Changes or modifications not expressly approved by Visonic Ltd. could void the user's authority to operate the 
equipment.

 

WARNING

! To comply with FCC and IC RF exposure compliance requirements, 

the  device  should  be  located  at  a  distance  of  at  least  20  cm  from  all  persons 
during  normal  operation.  The  antennas  used  for  this  product  must  not  be  co-
located or operated in conjunction with any other antenna or transmitter. 

This  device  complies  with  FCC  Rules  Part  15  and  with  Industry

 

Canada 

license-exempt RSS standard(s). Operation is subject to two conditions: (1) 
This  device  may  not  cause  harmful  interference,  and  (2)  this  device  must 
accept  any  interference  that  may  be  received  or  that  may  cause  undesired 
operation

Le  présent  appareil  est  conforme  aux  CNR  d'Industrie  Canada  applicables 
aux appareils radio exempts de licence. L'exploitation est autorisée aux deux 
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) 
l'utilisateur  de  l'appareil  doit  accepter  tout  brouillage  radioélectrique  subi, 
même si le brouillage est susceptible d'en compromettre le fonctionnement. 

 

 

W.E.E.E. Product Recycling Declaration

 

For   information  regarding  the  recycling    of  this  product    you  must  contact  the    company  from  which  you  orignially  purchased  it.  If  you  are  discarding  this  product  and  not 
returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste. 
Directive 2002/96/EC Waste Electrical and Electronic Equipment.

 

 

 
 
 
 
 
 
 

 

Отзывы: