LIMITED WARRANTY

Products manufactured by Tyco Fire Products are war-
ranted solely to the original Buyer for ten (10) years
against defects in material and workmanship when paid
for and properly installed and maintained under normal
use and service. This warranty will expire ten (10) years
from date of shipment by Tyco Fire Products. No warranty
is given for products or components manufactured by
companies not affiliated by ownership with Tyco Fire Prod-
ucts or for products and components which have been
subject to misuse, improper installation, corrosion, or
which have not been installed, maintained, modified or re-
paired in accordance with applicable Standards of the Na-
tional Fire Protection Association, and/or the standards of
any other Authorities Having Jurisdiction. Materials found
by Tyco Fire Products to be defective shall be either re-
paired or replaced, at Tyco Fire Products’ sole option.
Tyco Fire Products neither assumes, nor authorizes any
person to assume for it, any other obligation in connec-
tion with the sale of products or parts of products. Tyco
Fire Products shall not be responsible for sprinkler sys-
tem design errors or inaccurate or incomplete information
supplied by Buyer or Buyer’s representatives.

IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LI-
ABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UN-
DER ANY OTHER LEGAL THEORY, FOR INCIDENTAL,
INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES,
INCLUDING BUT NOT LIMITED TO LABOR CHARGES,
REGARDLESS OF WHETHER TYCO FIRE PRODUCTS
WAS INFORMED ABOUT THE POSSIBILITY OF SUCH
DAMAGES, AND IN NO EVENT SHALL TYCO FIRE
PRODUCTS’ LIABILITY EXCEED AN AMOUNT EQUAL
TO THE SALES PRICE.

THE FOREGOING WARRANTY IS MADE IN LIEU OF
ANY AND ALL OTHER WARRANTIES EXPRESS OR IM-
PLIED, INCLUDING WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE.

ORDERING PROCEDURE

Please Specify:

4.2 K-Factor, Star Galaxy SGQR
Quick Response Horizontal Sidewall
Sprinkler (#2977)

5.6 K-Factor, Star Galaxy SGQR
Quick Response Horizontal Sidewall
Sprinkler (#2973)

Recessed Escutcheon (#2084 or #2085, as applicable)

W-Type 9 Sprinkler Wrench (#1849)

W-Type 10 Recessed Sprinkler Wrench (#1948)

Refer to Price List for for complete listing of Part Num-
bers with respect to temperature ratings, sprinkler fin-
ishes, recessed escutcheon finishes, etc.

STAR SPRINKLER

1-1.3.11

Page 5

OBSOLETE

Содержание Star Galaxy SGQR

Страница 1: ...chemical to which the sprinklers will be ex posed WARNINGS The Star Galaxy SGQR Sprinklers described herein must be installed and maintained in compliance with this docu ment as well as with the applicable standards of the Na tional Fire Protection Association in addition to the stand ards of any other authorities having jurisdiction Failure to do so may impair the integrity of these devices The o...

Страница 2: ...m of torque may be used to install sprinklers with 1 2 NPT connections Higher lev els of torque may distort the sprinkler inlet with conse quent leakage or impairment of the sprinkler Do not attempt to make up for insufficient adjustment in the escutcheon plate by under or over tightening the STAR SPRINKLER Page 2 1 1 3 11 FIGURE 2 4 2 and 5 6 K FACTOR STAR GALAXY SGQR HORIZONTAL SIDEWALL SPRINKLE...

Страница 3: ...F 93 C Green 286 F 141 C Blue Lead Coated Polyester Coated All Colors SPRINKLER FINISH 5 6 K Factor Recessed Horizontal Sidewall S2973 With 2084 Escutcheon Temperature Rating Bulb Liquid Code Natural Brass Chrome Plated Polyester Coated All Colors 1 2 3 4 1 2 3 4 1 2 135 F 57 C Orange 155 F 68 C 175 F 79 C Red Yellow 200 F 93 C Green SPRINKLER FINISH 4 2 K Factor Horizontal Sidewall S2977 Temperat...

Страница 4: ...and all personnel who may be affected by this action must be notified Absence of an escutcheon which is used to cover a clear ance hole may delay the time to sprinkler operation in a fire situation Sprinklers which are found to be leaking or exhibiting vis ible signs of corrosion must be replaced Automatic sprinklers must never be shipped or stored where their temperature will exceed 100 F 38 C an...

Страница 5: ...oducts Tyco Fire Products shall not be responsible for sprinkler sys tem design errors or inaccurate or incomplete information supplied by Buyer or Buyer s representatives IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LI ABLE IN CONTRACT TORT STRICT LIABILITY OR UN DER ANY OTHER LEGAL THEORY FOR INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LABOR CHARGES REGARDLESS OF...

Страница 6: ...STAR SPRINKLER Page 6 1 1 3 11 7071 S 13th Street Suite 103 Oak Creek WI 53154 www starsprinkler com PRINTED IN U S A 3 01 O B S O L E T E ...

Отзывы: