background image

ORDERING PROCEDURE

A Product Symbol Number (PSN) is
not specified when ordering polyester
coated Model F685 Sprinklers with
other than a white color or when order-
ing color coated F705 Recessed Es-
cutcheons with other than white color.
It is suggested that a color chip be
provided when ordering special color
finishes. Otherwise, responsibility for
duplication cannot be accepted.

Contact your local distributor for avail-
ability.

Sprinkler Assembly:

Specify: (specify temperature rating)
Model F685 Designer Residential
Horizontal Sidewall Sprinkler with
(specify type) finish, PSN (specify).

Chrome Plated Finish

155°F/68°C . . . . . . . . . . PSN 51-685-9-155

Natural Brass Finish

155°F/68°C . . . . . . . . . . PSN 51-685-1-155

White Polyester Finish

155°F/68°C . . . . . . . . . . PSN 51-685-4-155

Chrome Plated Finish

175°F/79°C . . . . . . . . . . PSN 51-685-9-175

Natural Brass Finish

175°F/79°C . . . . . . . . . . PSN 51-685-1-175

White Polyester Finish

175°F/79°C . . . . . . . . . . PSN 51-685-4-175

Recessed Escutcheon:

Specify: 1/2" (15 mm) Model F705 Re-
cessed Escutcheon with (specify fin-
ish), PSN (specify).

1/2" (15 mm) F705

Chrome Plated . . . . . . PSN 56-705-9-010

1/2" (15 mm) F705

White Color
Coated . . . . . . . . . . PSN 56-705-4-010

Sprinkler Wrench:

Specify: W-Type 7 Sprinkler Wrench,
PSN 56-850-4-001.

Order for NFPA publications should be
addressed to the:

Publication Sales Department
NFPA
Batterymarch Park
Quincy, MA 02269

WEIGHT

The nominal weight of the Model F685
Designer Residential Horizontal Side-
wall Sprinkler is 2.6 ounces.

OBSOLETE

Содержание Gem F685

Страница 1: ...or up to 1 2 inch 12 7 mm of total adjustment from the flush sidewall position The F705 has a separable two piece design which allows installation of the sprinklers and pressure testing of the fire pr...

Страница 2: ...his condition consult the authorities having jurisdiction for guidance and approval It is the responsibility of an in stalling contractor to provide a copy of this document to the owner or his represe...

Страница 3: ...SED DIMENSIONS Up to 1 4 inch adjustment from minimum 1 4 inch to maximum 1 2 inch recessed position HIGH ADJUSTMENT DIMENSIONS Up to 1 2 inch adjustment from the flush sidewall position to 1 2 inch r...

Страница 4: ...ided by the manu facturer NOTES 1 Residential Fire Sprinkler Sys tems should only be designed and installed by those compe tent and completely familiar with automatic sprinkler sys tem design installa...

Страница 5: ...nterlines along the boundaries separating adjacent sprinkler coverage areas It is recommended that as part of the sprinkler system design the designer review the dwelling plans and where appropriate a...

Страница 6: ...can be used to com pensate for the possible manufac turing variations in the take out of the fitting as well as in the make in of the sprinklers as permitted by ANSI B1 20 1 3 After installing the F7...

Страница 7: ...the heat responsive element Bulb can result Do NOT cleanse the sprinklers with soap and water detergents ammonia cleaning fluids or other chemicals Remove dust lint cobwebs cocoons insects and larvae...

Страница 8: ...sh 155 F 68 C PSN 51 685 9 155 Natural Brass Finish 155 F 68 C PSN 51 685 1 155 White Polyester Finish 155 F 68 C PSN 51 685 4 155 Chrome Plated Finish 175 F 79 C PSN 51 685 9 175 Natural Brass Finish...