![Tyco Electronics 7-0528441-6 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/tyco-electronics/7-0528441-6/7-0528441-6_operating-instructions-manual_1186223013.webp)
Page 13 / 18 ECOC: EGC0 ; LOC: AI
PN 9-744012-3
412-18799 Rev.C
2.3 Notes on service and maintenance
It is absolutely essential that tool and equipment parts on which maintenance or service jobs have to be
carried out are disconnected from the electricity supply, unless anything to the contrary is stated in the
operating manual.
The disconnected parts must first be checked to ensure that they no longer carry any current; then they
must be earthed and short-circuited. Adjacent parts carrying current must be insulated.
The electrical equipment of the tool must be checked regularly, faults such as loose connections or
scorched cables must be removed immediately.
If it should be necessary to carry out work on parts which carry current, it is important to engage the
assistance of a second person who, in cases of emergency, can operate the emergency stop or the main
switch or can cut off the electricity supply to the tool. Only insulated tools should be used!
3 Intended use
With the hand pliers pn 7-0528441-6 the following Tyco Electronics connectors may be processed in
conjunction with the wires listed below:
Connector:
Sealed Connector for Solid State LED Lighting Application
pn 293172
Wires:
- Ribbon cable 4x26AWG
- Solid wire 0,75mm²
- Solid wire 0,50mm²
- Solid wire 18AWG
- Solid wire 20AWG
The outer diameter of the wires may not exceed 2,1mm!
Note:
The tool is to be used only and exclusively for the purpose described!
4 Technical data
Dimensions:
approx. 205x110x50mm
Weight:
approx. 700g
Electrical connection:
/
Pneumatic connection:
/
Sound pressure level:
/
Transportation:
Plastic Case