Page 15 / 17 ECOC: EGC0 ; LOC: AI
PN 8-744013-1
412-18911 Rev.A
Figure 4
6 Operation
1. The Pistol Grip hand tool must be set to its basic position. The pin with the part number 964318 is
inserted to the stop into the support nut (see figure 5). After that the socket is inserted.
Figure 5
2.
The socket with the part number 964320 must be inserted between the springs (see figure 6). It is to
be assured that the socket fits flush and clamps between the springs. The magnet wire is slid into the
female part and must overlap on the other side. The excessive magnet wire is cut off while pressing the
pin into the socket. During this process the magnet wire must held in position by hand.