45° SHIELDS G4 WITH DRAKA CABLE 

411-15684

 

Rev. O 

 

4 to 4

 

2.3.   Procedure for crimping the two shield legs. 

Important 

This step has to be done after crimping the ferrule on the Connect 

Systems tool number ‘391-1’ (see picture 6,7, 8). 

 

 

Picture 6 

Picture 7

 

Picture 8

 

 

When crimping the two shield legs, upper and lower shield must be positioned in 
order to close the gap between shields. 

After the two legs crimping the allowed remaining front gap for both connector side 
must be less than 0.2mm as shown on picture 9 and picture 10. 

 

 

 
 
 
 
 
 

Picture 9 

Picture 10 

 

 

 

 

Left Connector Side 

Right Connector Side 

Front Gap