background image

409--10096

Customer Manual

1

of 9

LOC B

E

2009 Tyco Electronics Corporation, Harrisburg, PA

All International Rights Reserved

TE logo and Tyco Electronics are trademarks.

*Trademark. Other products, logos, and company names used are the property of their respective owners.

TOOLING ASSISTANCE CENTER 1--800--722--1111

This controlled document is subject to change.

For latest revision and Regional Customer Service,

visit our website at

www.tycoelectronics.com

27 AUG 09 Rev A

Air- Powered Hydraulic

Pump 2119010- 1

READ THIS FIRST !

2

. . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY PRECAUTIONS

1. INTRODUCTION

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2. SAFETY PRECAUTIONS

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3. OPERATING PRECAUTIONS FOR THE PUMP

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4. PREPARATION AND SETUP

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.1. Hydraulic Connections

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2. Hand Controller Installation

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.3. Foot Controller Installation

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.4. Air Supply Hook--Up

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.5. Venting the Reservoir

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5. CONTROLLING THE PUMP

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.1. Priming the Pump Unit

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.2. Operating the Pump

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.3. Crimping Procedure

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6. MAINTENANCE AND INSPECTION

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6.1. Lubrication (For Hand/Foot, Manual Valve, and Remote Control Operated Pumps) 7
6.2. Bleeding Air from the System

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6.3. Inspecting the Hydraulic Fluid Level

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6.4 Draining and Flushing the Reservoir

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6.5 Refilling the Reservoir

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6.6 Periodic Cleaning

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7. TROUBLESHOOTING

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8. REPAIR/REPLACEMENT

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9. REVISION SUMMARY

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Содержание 2119010- 1

Страница 1: ...TY PRECAUTIONS 1 INTRODUCTION 3 2 SAFETY PRECAUTIONS 4 3 OPERATING PRECAUTIONS FOR THE PUMP 4 4 PREPARATION AND SETUP 5 4 1 Hydraulic Connections 5 4 2 Hand Controller Installation 5 4 3 Foot Controll...

Страница 2: ...ts of the application equipment D NEVER insert hands into installed application equipment D NEVER alter modify or misuse the application equipment TOOLING ASSISTANCE CENTER CALL TOLL FREE 1 800 722 11...

Страница 3: ...c Pump 2119010 1 is a portable air powered hydraulic pump used to power hydraulic crimping heads The pump comes with a male hydraulic coupler and a hydraulic pressure gage The hand or foot controllers...

Страница 4: ...d correct function before each use Do not use machinery that is not in proper working order but repair or replace it as necessary S Replace worn or damaged safety decals S Do not modify the product S...

Страница 5: ...non hardening thread sealant TEFLOND tape may also be used to seal hydraulic connections provided only one layer of tape is used Apply the tape carefully two threads back to prevent it from being pin...

Страница 6: ...an be potentially hazardous Therefore D Hydraulic connections must be securely fastened before building pressure in the system D Release all system pressure before loosening any hydraulic connection i...

Страница 7: ...he terminal or splice 4 Insert the stripped wire s into the wire barrel of the terminal or splice If possible insert the wires into both ends of a splice for the first crimp If the first crimp is made...

Страница 8: ...5 Drain and clean the reservoir once more 6 Refill the reservoir with approved hydraulic fluid and replace the pump assembly with gasket on the reservoir and install the screws Torque the screws as f...

Страница 9: ...ly should be set to produce the desired hydraulic pressure Pump will not build to maximum pressure no visible leakage 2 Pressure regulator improperly adjusted if so equipped 2 Adjust according to inst...

Отзывы: