background image

98 

http://www.tyan.com

 

 

 

CPU_Tct1_Value 

Temperature of the CPU_Tct1 

MB_Air_Inlet 

Temperature of the MB_Air_Inlet    Area 

SAS_Air_Outlet 

Temperature of the SAS_Air_Outlet    Area 

SAS_Air_Inlet 

Temperature of the SAS_Air_Inlet    Area 

CPU_CORE_MOSFET 

Temperature of the CPU_ CORE_MOSFET 

CPU_SOC_MOSFET 

Temperature of the CPU_ SOC_MOSFET 

DIMM_MOSFET_1   

Temperature of the DIMM MOSFET_1   

DIMM_MOSFET_2 

Temperature of the DIMM MOSFET_2   

P0_D1_UMC0_CH_A 

The highest temperature of CPU0 D1UMC0    channel A slot   

P0_D1_UMC1_CH_B 

The highest temperature of CPU0 D1 UMC1 channel B slot   

P0_D0_UMC1_CH_C 

The highest temperature of CPU0 D0 UMC1 channel C slot   

P0_D0_UMC0_CH_D 

The highest temperature of CPU0 D0 UMC0 channel D slot   

P0_D3_UMC0_CH_E 

The highest temperature of CPU0 D3 UMC0 channel E slot   

P0_D3_UMC1_CH_F 

The highest temperature of CPU0 D3 UMC1 channel F slot   

P0_D2_UMC1_CH_G 

The highest temperature of CPU0 D2 UMC1 channel G slot   

P0_D2_UMC0_CH_H 

The highest temperature of CPU0 D2 UMC0 channel H slot   

BIOS FAN Sensor 

Name Explanation 

CPU0_FAN 

Fan speed of CPU0_FAN 

Содержание TS65A-B8036

Страница 1: ...TS65A B8036 Service Engineer s Manual ...

Страница 2: ...bility or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without notice In no event will MITAC be held liable for any direct or indirect incidental or consequential damage loss of use loss of data or other malady resulting from errors or inaccuracies of information containe...

Страница 3: ...are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause h...

Страница 4: ...re There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Dispose of used battery according to manufacturer instructions and in accordance with your local regulations VCCI A この装置は クラスA情報技術装置です この装置を家庭環境で使用すると電波妨 害を引き起こすことがあります この場合には使用者が適切な対策を講ずるよう要 求されることがあります Safety IEC EN 60950 1 This equipment is compliant ...

Страница 5: ...ntroduction to the TYAN TS65A B8036 barebones and standard parts list describes the external components gives an overview of the product from different angles Chapter 2 Setting Up This chapter covers procedures on installing the memory modules hard drivers and other optional parts Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre in...

Страница 6: ... the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not be in the way of foot traffic Follow all warnings and cautions in this manual and on the unit case Do not push objects in the ventilation slots as they may touch high voltage components and...

Страница 7: ...ent Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning This symbol indicates the presence of hazardous energy circuits or electric shock hazards Refer all servicing to qualified personnel Warning This sy...

Страница 8: ... shock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rack by yourself a minimum of two people are needed to move a rack Do not attempt to move a fully loaded rack Remove equi...

Страница 9: ... and back of the rack or remove the doors to ensure adequate air flow to the system If you install the Model in a rack do not place equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that are improperly matted with the rails might be unstable Verify that the AC power supply branch ci...

Страница 10: ...s risk of fire and burns Do not disassemble crush puncture short external contacts or dispose of the battery in fire or water Do not expose the battery to temperatures higher than 60 C 140 F The system battery is not replaceable If the battery is replaced by an incorrect type there is danger of explosion Replace the battery only with a spare designated for your product Do not attempt to recharge t...

Страница 11: ...e all watches rings or loose jewelry when working before removing covers and touching internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service p...

Страница 12: ...1 2 Removing the Air Duct 35 2 1 3 Board Image 36 2 1 4 Block Diagram 38 2 1 5 Motherboard Mechanical Drawing 39 2 1 6 Board Parts Jumpers and Connectors 40 2 1 7 Installing the CPU and Heatsink 43 2 1 8 Installing the PCI E Card 46 2 1 9 Installing the Memory 49 2 1 10 Installing Hard Drives 51 2 2 Rack Mounting 55 2 2 1 Installing the Server in a Rack 55 Chapter 3 Replacing Pre Installed Compone...

Страница 13: ...bution Board 76 3 9 1 Power Distribution Board Features 77 3 9 2 Pin Definitions 78 3 10 Replacing the Power Backplane Board 80 3 11 Replacing the Rear HDD Backplane Board 82 3 11 1 HDD Backplane Features 83 3 11 2 HDD LED Definition 84 3 12 Replacing the Power Supply 85 3 13 Disconnecting All Motherboard Cables 86 3 13 1 Removing the Motherboard 87 Appendix I Installing IO Plate for OCP Card 89 A...

Страница 14: ...14 http www tyan com NOTE ...

Страница 15: ...IT demand but also offers a smooth path for future application usage TYAN also offers the TS65A B8036 in a version that can support up to twenty hot swap 2 5 SATA HDD SSD or sixteen NVMe SSD plus four hot swap 2 5 SATA HDD SSD and eight hot swap 2 5 HDD The TS65A B8036 uses TYAN s latest chassis featuring a robust structure and a solid mechanical enclosure All of this provides TS65A B8036 the powe...

Страница 16: ...D rear HDD Backplane Support SAS 12Gb s SATA 6Gb s Supported HDD Interface 26 SATA 6Gb s front 2 SATA 6Gb s rear Notification The SAS SATA HDD backplane is connected to onboard SATA connection by default Please contact Tyan technical support if a discrete SAS HBA RAID adapter installed is required System Cooling Configuration FAN 3 8cm fans Power Supply Type RPSU Input Range AC 200 240V 7A AC 100 ...

Страница 17: ... E Gen4 1 M8036 L24 3F riser card for 2 FH HL 1 HH HL PCI E Gen4 x8 slots left 1 M8036 R24 3F riser card for 2 FH HL 1 HH HL PCI E Gen4 x8 slots right Others 1 PCI E Gen3 x16 OCP 2 0 slot conn A conn B Conn B of OCP 2 0 mezzanine is mux d with the HH HL PCI E x8 slot on M8036 R24 3F riser LAN Q ty Port 2 GbE ports 1 GbE dedicated for IPMI Controller Broadcom BCM5720 PHY Realtek RTL8211E Storage SA...

Страница 18: ...chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC 10 100 1000 Mb s MAC...

Страница 19: ...lass A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Barebone 1 TS65A B8036 Barebone Manual 1 Quick Installation Guide ...

Страница 20: ...s SATA 6Gb s NVMe Supported HDD Interface 10 SATA 6Gb s 16 NVMe front 2 SATA 6Gb s rear Notification The SAS SATA HDD backplane is connected to onboard SATA connection by default Please contact Tyan technical support if a discrete SAS HBA RAID adapter installed is required System Cooling Configuration FAN 3 8cm fans Power Supply Type RPSU Input Range AC 200 240V 7A AC 100 127V 13A Per inlet 13A 7A...

Страница 21: ...L PCI E Gen4 x8 slots left 1 M8036 R24 3F riser card for 2 FH HL 1 HH HL PCI E Gen4 x8 slots right Others 1 PCI E Gen3 x16 OCP 2 0 slot conn A conn B Conn B of OCP 2 0 mezzanine is mux d with the HH HL PCI E x8 slot on M8036 R24 3F riser LAN Q ty Port 2 GbE ports 1 GbE dedicated for IPMI Controller Broadcom BCM5720 PHY Realtek RTL8211E Storage Additional SATA Connector 4 SATA Controller Marvell 92...

Страница 22: ...hers Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC 10 100 1000 Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature Hardware Monitor SMBIOS 3 0 PnP Wake on L...

Страница 23: ...70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Barebone 1 TS65A B8036 Barebone Manual 1 Quick Installation Guide NOTE 1 The specifications are subject to change without prior notice 2 Please visit our website for the latest specifications ...

Страница 24: ...8036GM2NE MB 1 M1718T65 FPB Front Panel Board 1 M1717T65 USB USB Board 1 M7100F48B PDB Power Distribution Board 1 M7063F86 PBP Power Backplane Board 1 M8036 R24 3F riser card 1 1 M8036 L24 3F riser card 2 1 M1295T65 BP12 8 HDD Backplane Board 2 M1296T65 BP12E 8 HDD Backplane Board 1 M1298T65 BP12E 2 Backplane Board B8036T65AV28HR LE 2 TF PWR ASSY SBU 1200W PSU MODULE pre installed 3 80 80 38mm Fan...

Страница 25: ... contact your retailer or browse to TYAN s website for service http www tyan com 1 Rail kit and screws 2 Power Wire Mount 2 CPU Heatsink 2 US power cord 2 EU power cord 1 IO PLATE LAN Kit with gasket 1 IO PLATE SFP Kit 1 2 5 HDD screw pack 1 TYAN Quick Installation Guide 1 M 2 Screw ...

Страница 26: ... M1717T65 USB USB Board 1 LAN1LED 7 ID Button 2 LAN2 LED 8 Power Button with green LED 3 ID LED 9 USB 3 1 Port 4 Warning LED 10 USB 3 1 Port 5 HDD LED 11 3 5 2 5 SSD HDD NVMe bays 6 RESET Button NVMe SKU 00 15 from M B NVMe port 16 23 from SAS card option 24 25 from M B SATA port LE SKU 00 19 from M B SATA port 20 25 from SAS card option ...

Страница 27: ...ed Solid on Warning 1 Red Green Blue System normal All off Memory warning Green blinking PSU warning Blue solid on FAN warning Blue blinking System fault Red solid on HDD LED 1 Green Red HDD present Green solid on HDD activity Green blinking HDD fail Red solid on DRIVE STATE Active LED Green Status LED Red Drive Present No Active Solid on Off Drive Present with Active Blinking Off Drive Failure Do...

Страница 28: ...l Port COM1 USB3 1 Ports 10 Dedicate to IPMI Port LAN3 4 RJ45 LAN Port LAN2 LAN1 11 VGA Port 5 Dedicate to OCP Card 12 Add On Card field 6 ID Button 13 Add On Card field 7 ID LED Blue ID LED LED State Color Description ID LED On Blue System identified Off Off System not identified ...

Страница 29: ... LEDs to indicate LAN status The chart below illustrates the different LED states 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Right LED 10 Mbps Link Green Off Active Blinking Green Off 100 Mbps Link Green Green Active Blinking Green Green 1000 Mbps Link Green Amber Active Blinking Green Amber No Link Off Off ...

Страница 30: ...30 http www tyan com 1 5 3 System Top View ...

Страница 31: ...M1296TS65 BP12E 8 M1298T65 BP12E 2 HDD Backplane Board 5 3 System fans 6 M7100F48B PDB Power Distribution Board 7 M7063F86 PBP Power Backplane Board 8 Power Module 9 Riser Card Bracket M8036 L24 3F M8036 R24 3F pre installed 10 Memory Slots 11 CPU Sockets 12 PCIE3 0 SLOT x24 13 OCP A Slot OCP1_A 14 OCP B Slot OCP1_B ...

Страница 32: ... can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static pad A T20 Security Torx screwdriver Most of the electrical and mechanical connections can be disconnected with your hands It is recommended that you do not use pliers to remove...

Страница 33: ... any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static surface until you are ready to reinstall it Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do so Do...

Страница 34: ... describes how to install components on to the mainboard including CPUs memory modules and add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove TS65A B8036 chassis cover 1 Release the latch on the left side 2 Slide to lift the rear top cover up ...

Страница 35: ...35 http www tyan com 2 1 2 Removing the Air Duct 1 Remove two PCIE bracket and the air duct from the chassis ...

Страница 36: ...36 http www tyan com 2 1 3 Board Image S8036GM2NE ...

Страница 37: ...37 http www tyan com S8036GM2NE LE This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture ...

Страница 38: ...38 http www tyan com 2 1 4 Block Diagram S8036 Block Diagram ...

Страница 39: ...39 http www tyan com 2 1 5 Motherboard Mechanical Drawing ...

Страница 40: ...ision available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM population guidelines shown later in the manual For the latest board revision please visit our web site at http www tyan com ...

Страница 41: ...ATADOM2 35 CPU SMBUS Header HDR_5 13 SATA Connector SATA4 36 CPU SMBUS Header HDR_4 14 SATA Connector SATA3 37 FAN Header FAN_HD1 15 RearFan_2 SYS_FAN_5 38 Front Panel Header FPIO_2 16 RearFan_1 SYS_FAN_4 39 PSMI Header PSMI_HD1 17 SATA Connector SATA 3 0 signals 7Pin 2Power SATADOM1 40 IPMB Header IPMB1 18 Vertical Type A USB Connector TYPEA_USB1 41 8 pin Power Connector PW3 19 FPB USB2 0 USB3 0 ...

Страница 42: ...D_LED LED5 vii NGFF1_LED LED_M1 iii RESET_LED_LED LED7 viii NGFF2_LED LED_M2 iv P0_PROCHOT_ LED LED4 ix Onboard BMC IPMI ALERT LED IPMI__LED2 v Rear ID LED ID_LED2 x HDD_ACT_LED HDD_LED3 NOTE 1 SD card socket is an OEM reserved feature which is not enabled on current product offering 2 HDR_1 5 NVME Hotplug I2C connector for NVME HDD backplane ...

Страница 43: ...sen the screws securing the force frame in a sequential order 3 2 1 Note The force frame will automatically eject after the captive screws are being released 2 By placing your both index fingers on the sides on the metal handle pull to release the rail frame Then lift the rail frame to its fully open position 3 Remove the external cap from the rail frame ...

Страница 44: ...rame with package into the slot on the rail frame Note During installation observe the following NOTE During installation observe the following 1 Make sure to push the carrier frame with package towards the end of the rail frame until it clicks into place 2 Do not drop the carrier frame or touch the package pad to avoid component damage ...

Страница 45: ...il frame firmly until it locks in place 7 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure the force frame in a sequential order 1 2 3 8 To secure the heatsink use a T30 Security Torx to tighten the screws Tighten the four screws in a diagonal sequence to secure the heat sink ...

Страница 46: ...46 http www tyan com 2 1 8 Installing the PCI E Card Follow these instructions to install the PCI E card 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis ...

Страница 47: ... com 3 Unscrew to remove the dummy brackets 4 Insert the PCI E card into the riser card bracket and screw it firmly Follow the same procedures to insert the card to the other side of the riser card bracket if necessary ...

Страница 48: ...48 http www tyan com 5 The same procedure to install the PCIE card to the second riser card 6 Reposition and screw the riser card bracket into the chassis ...

Страница 49: ...memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly the memory slot locking levers lock automatically onto the indentations at the ends of the module Follow the recommended memory population table to install the other memory modules ...

Страница 50: ...50 http www tyan com Memory Population table ...

Страница 51: ...e SSDs and two 2 5 hot swap SSDs Installing 2 5 Hot Swap Hard Drives Follow these instructions to install a 2 5 HDD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and pull the locking lever open 2 Slide the HDD tray out ...

Страница 52: ...an com 52 3 Open the lock to place the 2 5 hard disk drive into the HDD tray 4 Lock the tray lever to secure HDD 5 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks into place ...

Страница 53: ...stall a 2 5 SSD HDD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and pull the locking lever open 2 Open the lock to place a 2 5 hard disk drive into the HDD tray 3 Lock the tray lever to secure HDD ...

Страница 54: ...54 http www tyan com 4 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks into place ...

Страница 55: ...talling the Server in a Rack Follow these instructions to mount the TYAN TS65A B8036 into an industry standard 19 rack NOTE Before mounting the TYAN TS65A B8036 in a rack ensure that all internal components have been installed and that the unit has been fully tested However to make the installation easier we suggest that you remove all HDD trays before you insert the chassis into the rack A B Slid...

Страница 56: ...ssis 1 Draw out the inner rail from the rail assembly When the rail comes to a stop pull the tab to release the latch and completely draw the inner rail out 2 Align the inner sliding rail on the side of the server and pull towards the arrow to secure the hooks ...

Страница 57: ...teps 2 to 4 to secure the sliding rail to the other side of the server Installing the Outer Rails to the Unit 1 Secure the outer rails to the rack on each side Rack Mounting the Server 1 Draw out the middle rail to the latch position ...

Страница 58: ...58 http www tyan com 2 When the inner rails come to a stop pull the tab to release the latch and push the whole system in 3 Secure the mounting ears of the unit to the rack using two M5 x 20L screws A ...

Страница 59: ...59 http www tyan com NOTE ...

Страница 60: ...board M1717T65 FPB Front Panel Board M1718T65 USB Board M1295T65 BP12 8 M1296T65 BP12E 8 HDD Backplane M1298T65 BP12 2 HDD Backplane M7100F48B PDB Power Distribution board M7063F86 PBP Power Backplane Board M8036 L24 3F and M8036 R24 3F Riser cards System fan and Power supply unit etc 3 2 Disassembly Flowchart The following flowchart outlines the disassembly procedure ...

Страница 61: ...e cover of the TS65A B8036 3 4 Replacing Motherboard Components Follow these instructions to replace motherboard components including the motherboard 3 4 1 Replacing the Riser Card Follow these instructions to replace the M8036 L24 3F and M8036 R24 3F Riser cards 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis ...

Страница 62: ...n com 3 Unscrew the M8036 L24 3F riser card to replace with a new one 4 Unscrew the M8036 R24 3F riser card to replace with a new one 5 Follow the steps described earlier in reverse to reinstall the riser card bracket ...

Страница 63: ...www tyan com 3 4 2 PCI E Riser Cards Specification M8036 L24 3F Riser Card 3 4 3 Connector Pin Definition M8036 L24 3F Location Definition J1 J2 J3 J4 PCIe X16 SLOT 4P Power Connector PCIe X8 SLOT PCIe X8 SLOT ...

Страница 64: ...36 R24 3F Riser Card 3 4 4 Connector Pin Definition M8036 R24 3F Location Definition J1 J2 J3 J4 J6 PCIe X8 SLOT 4Pin Power Connector PCIe X16 SLOT PCIe X8 SLOT PCIe X1 SLOT J2 PWR1 Pin Signal Pin Signal 1 12V 2 GND 3 GND 4 5V ...

Страница 65: ...p www tyan com 3 5 Replacing the Front Panel Board Follow these instructions to replace the M1718T65 FPB Front Panel Board 1 Unscrew to release the Front Panel Board cover 2 Remove the Front Panel Board cover ...

Страница 66: ...www tyan com 66 3 Unscrew the Front Panel Board to replace a new one 4 Disconnect the Front Panel Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the Front Panel Board ...

Страница 67: ...718T65 FPB Front Panel Board Form Factor PCB Dimensions 40 00 18 00 1 6mm Thickness 1 6mm Layer 4 layers Specifications power button with LED reset button ID button LED LAN1 LED green LAN2 LED green ID LED blue HDD LED green Red FAULT LED Red green Blue Power LED ...

Страница 68: ...http www tyan com 68 3 6 Replacing the USB Board Follow these instructions to replace the M1717T65 USB Board 1 Unscrew to release the USB front cover 2 Remove the USB front cover ...

Страница 69: ...http www tyan com 69 3 Unscrew the USB Board 4 Disconnect the USB Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the USB Board ...

Страница 70: ...tp www tyan com 70 3 6 1 USB Board Specifications M1717T65 USB USB Board Form Factor PCB Dimensions 48 00 19 00 1 6mm Thickness 1 6mm Layer 4 layers Specifications USB 3 1 Connector 5 2PIN input Connector ...

Страница 71: ...71 http www tyan com 3 7 Replacing the System Fan Follow these instructions to replace the fan 1 Take out the fan from the chassis 2 Replace a new fan to the chassis 3 Reinstall a new fan to the chassis ...

Страница 72: ...therwise the HDD backplane will be damage when strains at the disassembly 1 Disconnect all cables connected to the M1295T65 BP12 8 M1296T65 BP12E 8 HDD backplane Board 2 Unscrew the HDD BP Board 3 Release the HDD Backplane from the hook 4 Follow the procedures described earlier to reinstall the HDD backplane board bracket into the chassis ...

Страница 73: ...73 http www tyan com 3 8 1 HDD Backplane Board Features Front View M1295T65 BP12 8 Rear View ...

Страница 74: ...n SGPIO Header x 1 SATA SAS HDD x 8 Output 3 8 2 Connector Definition Location Definition HDD0 HDD1 HDD2 HDD3 HDD4 HDD5 HDD6 HDD7 SATA0_3 SATA4_7 PW1 SGPIO0 SGPIO1 SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector Mini SAS HD Connector Mini SAS HD Connector Power Connector SGPIO Header for HDD0 7 Reserved ...

Страница 75: ...BP12E 8 Rear View Form Factor PCB Dimensions 131mm 76mm 3mm Thickness 3mm Layer 8 layers Specifications Overview 10 Pin FAN Header x 1 SlimSAS Connector x4 Input 5Pin SGPIO Header x 2 NVMe HDD x 8 Output Smbus Header x1 HDR_1 FAN Connector x 3 ...

Страница 76: ...s to replace the M7100F48B PDB Power Distribution Board in your system 1 Disconnect all cables connected to the power distribution board 2 Unscrew to take off the power distribution board and replace with a new one 3 Insert the PDB into the chassis following the above procedures in reverse ...

Страница 77: ...n Board Features M7100F48B PDB Power Distribution Board Board Size 82mm x 127 3mm 6 layer PCB Integrated I O 3 8 pin power connector 3 4 pin power connector 2 20 pin power connector 1 24 pin power connector 1 PSMI connector 1 50 pin golden finger ...

Страница 78: ... Connector Definition Pin Pin Definition GND 1 2 GND 12V 3 4 5V PW6 PW7 PW8 8 pin Power Connector Definition Pin Pin Definition GND 1 5 12V GND 2 6 12V GND 3 7 12V GND 4 8 12V PW2 PW3 20 Pin Power Connector Definition Pin Pin Definition GND 1 11 12V GND 2 12 12V GND 3 13 12V GND 4 14 12V GND 5 15 12V GND 6 16 12V GND 7 17 12V GND 8 18 12V GND 9 19 12V GND 10 20 12V ...

Страница 79: ...om PW5 24 pin Power Connector Definition Pin Pin Definition 3 3V 1 13 3 3V 3 3V 2 14 NA GND 3 15 GND 5V 4 16 PS_ON GND 5 17 GND 5V 6 18 GND GND 7 19 GND PW_GD 8 20 NA 5VSB 9 21 5V 12V 10 22 5V 12V 11 23 5V 3 3V 12 24 GND ...

Страница 80: ...e Board Follow these instructions to replace the M7063F86 PBP Power Backplane Board 1 Unscrew the Power BP Board bracket from the chassis 2 Remove the bracket beside and release the power distribution tray 3 Slide to take out the power backplane board tray ...

Страница 81: ...81 http www tyan com 4 Unscrew to replace with a new power backplane board 5 Follow the steps described earlier in reverse order to reinstall the power backplane board tray into the chassis ...

Страница 82: ...2 http www tyan com 3 11 Replacing the Rear HDD Backplane Board Follow the instructions to replace the M1298T65 BP12 2 HDD backplane Board 1 Disconnect all cables and unscrew the power distribution board ...

Страница 83: ...sas Connector J1 SATA NVMe Connector NVME0 SATA NVMe Connector NVME1 SATA Connector SATA0 SATA Connector SATA1 4P Power CON PW1 Header for PCA9544 SMBUS address Select 3PHD 1 The rear 2 SATA SSDs HDDs SATA0 SATA1 are not available when AMD EPYC 7002 Series Processors deployed in all configurations Please contact Tyan Technical Support for more details ...

Страница 84: ...HDD LED Definition LED Color State Description HDD fail LED Red ON NVME SATA SAS HDD fail OFF No failure found HDD Power Access LED Green ON NVME SATA SAS HDD ready Blinking NVME SATA SAS HDD access activity OFF Power disconnected ...

Страница 85: ...ower Supply Follow these instructions to replace the power supply module in your system 1 Press the latch to pull the power supply out 2 After replacing a new power supply press and hold the latch to push the power supply back into the chassis ...

Страница 86: ...86 http www tyan com 3 13 Disconnecting All Motherboard Cables 1 Disconnect all cables connected to the motherboard ...

Страница 87: ...l of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the air duct processor and heatsink if installed 2 Remove nine screws securing the motherboard to the chassis 3 Carefully lift the motherboard from the chassis ...

Страница 88: ...88 http www tyan com NOTE ...

Страница 89: ...O Plate for OCP Card Follow these instructions to install the IO Plate for OCP Card Here shows how to install the IO Plate for the dual port LAN card M7062 I599 2T 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis ...

Страница 90: ...e semi shearing for the OCP card slot Discharge the metal slug 4 Take out the IO plate for LAN card Use a screwdriver to break the LAN port s semi shearing Break one semi shearing if a single port LAN card is installed Break both for a dual port LAN card ...

Страница 91: ...91 http www tyan com 5 Insert the IO Plate to the OCP card LAN port 6 Screw the IO Plate to the chassis ...

Страница 92: ...92 http www tyan com 7 Insert the LAN card into the OCP slot 8 Secure the LAN card to the chassis ...

Страница 93: ...6GM2NE MB SlimSAS 8I to SlimSAS 8I SLIMSAS1 SLIMSAS5 SlimSAS 8I to SlimSAS 8I SLIMSAS2 SLIMSAS6 SlimSAS 8I to SlimSAS 8I SLIMSAS3 SLIMSAS7 SlimSAS 8I to SlimSAS 8I SLIMSAS4 SLIMSAS8 HDR cable HDR 1 HDR_5 Front Backplane BP Board to S8036MB Cable HDD BP 3 M1295T65A BP12 8 Connect to S8036GM2NE MB Mini SAS 1 Not connected Mini SAS 2 B8036T65AV28HR LE SKU Front Backplane BP Board to S8036MB Cable HDD...

Страница 94: ...ar HDD BP M1298T65 BP12E 2 Connect to S8036GM2NE MB SATA 7P to SATA 7P SATA0 SATA3 SATA 7P to SATA 7P SATA1 SATA4 HDR cable HDR1 HDR4 2 System FAN cable FAN Connect to HDD BP M1297T65 BP12E 12 FAN1 J2 FAN2 J4 FAN3 J5 3 FAN Ctrl Cable HDD BP M1296T65A BPE 8 Connect to S8036GM2NE MB J7 FAN_HD1 4 FAN Ctrl Cable HDD BP M1295T65A BP12 8 Connect to S8036GM2NE LE MB J3 FAN_HD1 5 Front Panel Control Cable...

Страница 95: ...LE MB PW5 PW1 PW6 PW2 PW7 PW3 J1 PSMI HD1 8 Power Supply Cables M7100F48B PDB Connect to HDD BP M1297T65 BP12E 12 PW2 PW1 PW2 9 Power Supply Cables M7100F48B PDB Connect to Front HDD BP M1298T65 BP12E 2 PW9 PW1 10 Power Supply Cables M7100F48B PDB Connect to Rear HDD BP M1298T65 BP12E 2 PW9 PW1 ...

Страница 96: ...lanation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan speed rpm 2 Temp Sensor SYS_Air_Outlet RT3 and MB_Air_Inlet RT2 etc They detect the system temperature around NOTE The system temperature is measured in a scale defined by AMD not in Fahrenheit or C...

Страница 97: ...97 http www tyan com BIOS Temp Sensor Name Explanation ...

Страница 98: ...UMC0_CH_A The highest temperature of CPU0 D1UMC0 channel A slot P0_D1_UMC1_CH_B The highest temperature of CPU0 D1 UMC1 channel B slot P0_D0_UMC1_CH_C The highest temperature of CPU0 D0 UMC1 channel C slot P0_D0_UMC0_CH_D The highest temperature of CPU0 D0 UMC0 channel D slot P0_D3_UMC0_CH_E The highest temperature of CPU0 D3 UMC0 channel E slot P0_D3_UMC1_CH_F The highest temperature of CPU0 D3 U...

Страница 99: ...SYS_FAN_3 SYS_FAN_4 Fan speed of SYS_FAN_4 SYS_FAN_5 Fan speed of SYS_FAN_5 SYS_FAN_6 Fan speed of SYS_FAN_6 SYS_FAN_7 Fan speed of SYS_FAN_7 SYS_FAN_8 Fan speed of SYS_FAN_8 SYS_FAN_9 Fan speed of SYS_FAN_9 SYS_FAN_10 Fan speed of SYS_FAN_10 SYS_FAN_11 Fan speed of SYS_FAN_11 SYS_FAN_12 Fan speed of SYS_FAN_12 ...

Страница 100: ...rts FRU AS 0190 452T60900001 Slide Rail Kit Cable FRU CS 1210 422T60900001 250 mm SlimSAS 8i to SlimSAS 8i CABLE SlimSAS 8i 74P SlimSAS 8i 74P FRU CS 1170 422T60900002 550 mm SlimSAS 8i to SlimSAS 8i CABLE SlimSAS 8i 74P SlimSAS 8i 74P FRU CS 1220 422T60900005 550 mm SlimSAS 8i to MiniSAS HD CABLE SlimSAS 8i 74P MiniSAS HD 36P 2 FRU CS 0330 332810000514 A C Power Cord L 1800mm US type CCBL 0300 33...

Страница 101: ...es such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find their latest software and operating system components to keep their systems running as powerful and productive as possible MITAC also ranks high for its commitm...

Страница 102: ...proper maintenance of products Note A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufacturer for a Return Merchandise Authorization RMA number The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid TYAN will pay ...

Отзывы: