background image

 

http://www.tyan.com 

282 

6.2      AMIBIOS Post Code (Aptio) 

 

The POST code checkpoints are the largest set of checkpoints during the BIOS 
pre-boot process.    The following table describes the type of checkpoints that may 
occur during the POST portion of the BIOS: 

Checkpoint Ranges 
Status Code Range 

Description 

0x01 – 0x0B 

SEC execution 

0x0C – 0x0F 

SEC errors 

0x10 – 0x2F 

PEI execution up to and including memory detection 

0x30 – 0x4F 

PEI execution after memory detection 

0x50 – 0x5F 

PEI errors 

0x60 – 0x8F 

DXE execution up to BDS 

0x90 – 0xCF 

BDS execution 

0xD0 – 0xDF 

DXE errors 

0xE0 – 0xE8 

S3 Resume (PEI) 

0xE9 – 0xEF 

S3 Resume errors (PEI) 

0xF0 – 0xF8 

Recovery (PEI) 

0xF9 – 0xFF 

Recovery errors (PEI) 

 

Standard Checkpoints 

SEC Phase 

Status Code 

Description 

0x00 

Not used 

Progress Codes 

0x01 

Power on. Reset type detection (soft/hard). 

0x02 

AP initialization before microcode loading 

0x03 

North Bridge initialization before microcode loading 

0x04 

South Bridge initialization before microcode loading 

0x05 

OEM initialization before microcode loading 

0x06 

Microcode loading 

0x07 

AP initialization after microcode loading 

0x08 

North Bridge initialization after microcode loading 

0x09 

South Bridge initialization after microcode loading 

Содержание B7109F77DV10E4HR-2T-N

Страница 1: ...1 http www tyan com FT77D B7109 Service Engineer s Manual...

Страница 2: ...2 http www tyan com...

Страница 3: ...ing liability or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without no...

Страница 4: ...se limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio freq...

Страница 5: ...not puncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Disp...

Страница 6: ...tional parts Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components Chapter 4 Motherboard Information This chapter lis...

Страница 7: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Страница 8: ...bol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as...

Страница 9: ...ock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety require...

Страница 10: ...Model in a rack do not place equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that...

Страница 11: ...of explosion Replace the battery only with a spare designated for your product Do not attempt to recharge the battery Dispose of used batteries according to the instructions of the manufacturer Do not...

Страница 12: ...r plug has been damaged Liquid has been spilled on the product or an object has fallen into the product The product has been exposed to rain or water The product has been dropped or damaged The produc...

Страница 13: ...ng the Chassis Cover 61 2 1 2 Installing the CPU and Heat sink 63 2 1 3 Installing the Memory 69 2 1 4 Installing Expansion Cards Mainboard 74 2 1 5 Installing the Expansion Card OCP Riser Card 79 2 1...

Страница 14: ...28 4 3 Motherboard Mechanical Drawing 129 4 4 Board Parts Jumpers and Connectors 130 4 5 Thermal Interface Material 138 4 6 Tips on Installing Motherboard in Chassis 139 4 7 Installing the Memory 141...

Страница 15: ...ation 235 5 5 4 Memory Configuration 238 5 5 5 IIO Configuration 243 5 5 6 Advanced Power Management Configuration 258 5 6 Server Management 264 5 6 1 System Event Log 266 5 6 2 BMC Network Configurat...

Страница 16: ...http www tyan com 16 NOTE...

Страница 17: ...erver system is capable of offering scalable 32 and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation The FT77D B7109 not only empowers your company in nowadays...

Страница 18: ...2T N 14 2 5 SATA support FT77D B7109 B7109F77DV14HR 2T NF 14 2 5 SATA support support FT77D B7109 B7109F77DV14HR 8X 2T F 14 2 5 SATA support FT77D B7109 B7109F77DV10E4HR 2T NF 10 2 5 SATA 4 NVMe SSD...

Страница 19: ...p SSD HDD HDD Backplane Support SAS 12Gb s SATA 6Gb s NVMe Supported HDD Interface 4 SATA 6Gb s System Cooling Configuration Redundancy Yes FAN 5 1 hot swap 12cm fans Power Supply Type RPSU Input Rang...

Страница 20: ...el 6 Channels per CPU Memory voltage 1 2V Expansion Slots PCI E 2 PCI E Gen3 x8 Tyan Mezzanine slots 1 PCI E Gen3 x16 slot Full height full length single width 8 PCI E Gen3 x16 slots Full height full...

Страница 21: ...ST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboard management co...

Страница 22: ...oard Name S7109GM2NR 8X 2T Gross Weight 45 kg 99 5 lbs Net weight 26 kg 57 5 lbs Front Panel Buttons 1 RST 1 NMI 1 ID 1 PWR w LED LEDs 1 HDD 1 ID 1 Warning 3 LAN I O Ports 2 USB 3 0 ports Internal Dri...

Страница 23: ...MM slots DIMM Type Speed DDR4 RDIMM RDIMM 3DS LRDIMM LRDIMM 3DS 2666 DDR4 JEDEC NVDIMM 2666 Capacity Up to 768GB RDIMM 1 536GB LRDIMM 3 072GB RDIMM 3DS LRDIMM 3DS Follow latest Intel DDR4 Memory POR M...

Страница 24: ...mory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature...

Страница 25: ...ce Driver CD TYAN FT77D B7109 B7109F77DV14HR 2T N System Form Factor 4U Rackmount Chassis Model FT77D Dimension D x W x H 30 31 x 17 24 x 6 93 770 x 438 x 176mm Motherboard Name S7109GM2NR 2T Gross We...

Страница 26: ...Wattage Max up to 205W System Bus Up to 10 4 9 6 GT s with Intel UltraPath Interconnect UPI support Chipset PCH Intel C621 Switch IC 4 PLX PEX8747 Memory Supported DIMM Qty 12 12 DIMM slots DIMM Type...

Страница 27: ...hipset Aspeed AST2500 I O Ports USB 2 USB3 0 ports at front COM 1 DB 9 COM port at front VGA 1 D Sub 15 pin port at front RJ 45 2 10GbE ports 1 GbE dedicated for IPMI TPM Optional TPM Support Please r...

Страница 28: ...pport lists Regulation FCC SDoC Class A CE DoC Class A CB LVD Yes RCM Class A VCCI Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non opera...

Страница 29: ...7 63 Hz Output Watts Max 2 000 Watts 100 127V AC input Max 3 200Watts 200 240V AC input Efficiency PFC 80 plus Platinum Redundancy 2 1 NOTE When use 100V 127V AC input the system does not support redu...

Страница 30: ...N Riser Card 1 M2215 L8 1F riser card for 1 LAN mezz slot 1 M2217 L16 IO riser card for 1 storage mezz slot LAN Q ty Port 2 10GbE ports 1 PHY Controller Intel X550 AT2 PHY Realtek RTL8211E Storage SAT...

Страница 31: ...USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC 10 100 1000 Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature Hardware Monitor SMBIOS 3 0 PnP Wak...

Страница 32: ...LEDs 1 HDD 1 ID 1 Warning 3 LAN I O Ports 2 USB 3 0 ports Internal Drive Bay Q ty Type 14 2 5 Hot Swap SSD HDD HDD Backplane Support SAS 12Gb s SATA 6Gb s NVMe Supported HDD Interface 14 SATA 6Gb s Sy...

Страница 33: ...y Up to 768GB RDIMM 1 536GB LRDIMM 3 072GB RDIMM 3DS LRDIMM 3DS Follow latest Intel DDR4 Memory POR Memory channel 6 Channels per CPU Memory voltage 1 2V Expansion Slots PCI E 2 PCI E Gen3 x8 Tyan Mez...

Страница 34: ...PU memory system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Managem...

Страница 35: ...e Manual 1 Quick Installation Guide Installation CD 1 TYAN Device Driver CD FT77D B7109 B7109F77DV10E4HR 2T N System Form Factor 4U Rackmount Chassis Model FT77D Dimension D x W x H 30 31 x 17 24 x 6...

Страница 36: ...2 LGA3647 Supported CPU Series Intel Xeon Scalable Processor Thermal Design Power TDP Wattage Max up to 205W System Bus Up to 10 4 9 6 GT s with Intel UltraPath Interconnect UPI support Chipset PCH In...

Страница 37: ...Link 2 SFF 8612 for 4 NVMe ports via Tyan M2093 PCI E Gen3 x16 Card Graphic Connector type D Sub 15 pin Resolution Up to 1920x1200 Chipset Aspeed AST2500 I O Ports USB 2 USB3 0 ports at front COM 1 DB...

Страница 38: ...tion ACPI sleeping states S4 S5 ACPI 6 1 Operating System OS supported list Please refer to our AVL support lists Regulation FCC SDoC Class A CE DoC Class A CB LVD Yes RCM Class A VCCI Class A Operati...

Страница 39: ...ply Type RPSU Input Range AC 100 127V 12 9A AC 200 240V 9 5A Frequency 47 63 Hz Output Watts Max 2 000 Watts 100 127V AC input Max 3 200Watts 200 240V AC input Efficiency PFC 80 plus Platinum Redundan...

Страница 40: ...h double width Pre install TYAN Riser Card 1 M2215 L8 1F riser card for 1 LAN mezz slot 1 M2217 L16 IO riser card for 1 storage mezz slot LAN Q ty Port 2 10GbE ports 1 PHY Controller Intel X550 AT2 PH...

Страница 41: ...ST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboard management co...

Страница 42: ...76mm Motherboard Name S7109GM2NR 8X 2T Gross Weight 45 kg 99 5 lbs Net weight 26 kg 57 5 lbs Front Panel Buttons 1 RST 1 NMI 1 ID 1 PWR w LED LEDs 1 HDD 1 ID 1 Warning 3 LAN I O Ports 2 USB 3 0 ports...

Страница 43: ...mory Supported DIMM Qty 12 12 DIMM slots DIMM Type Speed DDR4 RDIMM RDIMM 3DS LRDIMM LRDIMM 3DS 2666 DDR4 JEDEC NVDIMM 2666 Capacity Up to 768GB RDIMM 1 536GB LRDIMM 3 072GB RDIMM 3DS LRDIMM 3DS Follo...

Страница 44: ...s 1 GbE dedicated for IPMI TPM Optional TPM Support Please refer to our TPM supported list System Monitoring Chipset Aspeed AST2500 Temperature Monitors temperature for CPU memory system environment V...

Страница 45: ...s Regulation FCC SDoC Class A CE DoC Class A CB LVD Yes RCM Class A VCCI Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humid...

Страница 46: ...lled M1284F77D BP12E 14 HDD Backplane Board pre installed only for 2 5 device SKU M1291F77D BP12E 4 HDD Backplane Board pre installed only for 3 5 2 5 device SKU M1713F77C FPB Front Panel Board pre in...

Страница 47: ...5 device SKU 16 6 Pin PCIe Power Cables only for N NF SKU 8 8 Pin PCIe Power Cables only for N NF SKU 8 8 Pin EPS 12V CPU Power Cables only for N NF SKU 8 GPU Card Holder Brackets w screws only for N...

Страница 48: ...http www tyan com 48 1 6 About the Product The following views show you the product 1 6 1 System Front View...

Страница 49: ...3 NA NA NA No Function 8 Power Power On Green Solid On Power Off Green Off 9 ID Located Blue Solid On Free Blue Off 10 HDD Activity Access Green Blinking 11 Warning Normal Amber Off BMC HWM system ale...

Страница 50: ...ve Blinking Off Drive Failure Off Solid On RAID Rebuild Blinking Blinking 4 Hz Drive Locate Identifier Blinking Blinking 1 Hz For 3 5 2 5 Device SKU M1291F77D BP12E 4 HDD BP pre installed LED Color St...

Страница 51: ...R Series B7109F77DV4HR Series No Description 1 PSU2 2 PSU1 3 PSU0 4 Mezzanine Card Slot 5 ID LED Button 6 LAN3 IPMI 7 LAN2 8 LAN1 9 PCIE Slots 10 Protective Earthing Terminal Screw type M6X1 NOTE With...

Страница 52: ...1 PSU2 2 PSU1 3 PSU0 4 Mezzanine Card Slot 5 ID LED Button 6 LAN3 IPMI 7 LAN2 8 LAN1 9 PCIE Slots 10 PCIE Slot M2093 pre installed for NVMe SKU 11 Protective Earthing Terminal Screw type M6X1 NOTE Wi...

Страница 53: ...Gbps Link Yellow Solid On Yellow Solid On Active Yellow Blinking Yellow Solid On 1Gbps LAN Port LAN Indication 1Gbps LAN Link Activity LED Scheme Left LED Link Activity LED Color Green Right LED Speed...

Страница 54: ...UVP OFF ON Power supply warning events where the power supply continues to operate but triggered high Temperature high Voltage high Current and low fan rpm critical limit OFF 1Hz Blinking Amber AC pr...

Страница 55: ...http www tyan com 55 1 6 4 System Top View B7109F77DV10E4HR 2T N SKU B7109F77DV10E4HR 2T 8X F SKU...

Страница 56: ...DD BP Board pre installed 15 M1713F77C FPB Front Panel Board 16 System Fans 17 CPU0 18 CPU1 19 M7059F77C D PDB Power Distribution Board 20 M7109F77D D PBP Power Backplane Board 21 2 1 Redundant Power...

Страница 57: ...http www tyan com 57 B7109F77DV4HR 2T NF SKU B7109F77DV4HR 2T 8X F SKU...

Страница 58: ...BP12E 4 HDD BP Board pre installed 5 M1713F77C FPB Front Panel Board 6 System Fans 7 CPU0 8 CPU1 9 M7059F77C D PDB Power Distribution Board 10 M7109F77D D PBP Power Backplane Board 11 2 1 Redundant Po...

Страница 59: ...ou from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an an...

Страница 60: ...metal chassis of the unit case or the bare metal body of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre install...

Страница 61: ...mponents on to the motherboard including CPUs memory modules and Add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove FT77D B7109 chassis cover 1 Loosen 2 thumb screws and...

Страница 62: ...http www tyan com 62 4 Release the latch to lift up the front top cover from the chassis...

Страница 63: ...ow the steps below on installing CPUs and CPU heatsinks 1 Align and install the processor on the carrier 2 Carefully flip the heatsink Then install the carrier assembly on the bottom of the heatsink a...

Страница 64: ...he heatsink has been removed from the processor you need to clean the processor and heatsink using an alcohol solvent Then apply new thermal grease before reinstalling the heatsink 4 Carefully flip th...

Страница 65: ...tighten the screws in a sequential order 1 2 3 4 NOTE When disassembling the heatsink loosen the screws in reverse order 4 3 2 1 6 Repeat the procedures described earlier to install the second process...

Страница 66: ...s below on installing Fabric CPUs and CPU heatsinks 1 Align and install the processor on the carrier 2 Carefully flip the heatsink Then install the carrier assembly on the bottom of the heatsink and m...

Страница 67: ...nk using an alcohol solvent Then apply new thermal grease before reinstalling the heatsink 4 Carefully flip the heatsink Align the heatsink with the CPU socket by the guide pins and make sure the gold...

Страница 68: ...ric CPU Note that it is easier to connect if you use a fabric cable with right angle connector 7 Press the lever down to secure the cable to the fabric CPU socket 8 Repeat the procedures described ear...

Страница 69: ...odules onto the motherboard 1 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly...

Страница 70: ...http www tyan com 70...

Страница 71: ...1 P0_MC0_DIM_CH_B0 P0_MC0_DIM_CH_B1 P0_MC0_DIM_CH_C0 P0_MC0_DIM_CH_C1 P0_MC1_DIM_CH_D0 P0_MC1_DIM_CH_D1 P0_MC1_DIM_CH_E0 P0_MC1_DIM_CH_E1 P0_MC1_DIM_CH_F0 P0_MC1_DIM_CH_F1 P1_MC0_DIM_CH_A0 P1_MC0_DIM_...

Страница 72: ...H_B0 P0_MC0_DIM_CH_B1 P0_MC0_DIM_CH_C0 P0_MC0_DIM_CH_C1 P0_MC1_DIM_CH_D0 P0_MC1_DIM_CH_D1 P0_MC1_DIM_CH_E0 P0_MC1_DIM_CH_E1 P0_MC1_DIM_CH_F0 P0_MC1_DIM_CH_F1 P1_MC0_DIM_CH_A0 P1_MC0_DIM_CH_A1 P1_MC0_D...

Страница 73: ...ates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM 4 Alway...

Страница 74: ...6 slots can support GPU Graphic Processing Unit cards Follow these instructions to install the PCIE cards Using GPU Bracket 1 Locate the PCI E Gen 3 x16 slot on the motherboard Unscrew to take out the...

Страница 75: ...crew the GPU card to the chassis Connect the GPU PWR cable to the Power Distribution Board NOTE Please remove the GPU air duct on the top cover for GTX cards or VGA cards which cable is on the top sid...

Страница 76: ...http www tyan com 76 Step 2 Unscrew the top cover to lift it up Step 3 Unscrew to separate the GPU air duct from the top cover...

Страница 77: ...http www tyan com 77 Step 3 Follow the procedures described earlier to replace the top cover Step 4 Screw the top cover to the chassis and replace 4 mylars as shown below...

Страница 78: ...w tyan com 78 Using Card Guide 1 Insert the card guide onto the power distribution board bracket 2 Insert the full length full height PCIE card into the PCIE Gen3 x16 slot and screw it firmly to the c...

Страница 79: ...ansion Card OCP Riser Card Follow these instructions to install the M7076 3008 8I onto the OCP Riser Card Slot 1 Locate the OCP Riser Card Slot 2 Insert the M7076 3008 8I onto the OCP Riser Card Slot...

Страница 80: ...2 1 6 Installing OPA Card optional Follow these instructions to install the OPA Card 1 Connect one end of the IFT sideband cable to the Sideband Header on the motherboard and the other end to the OPA...

Страница 81: ...CPU and the other end to P1 and P2 connector on the OPA card 3 Unscrew to remove the dummy bracket before installing the OPA card 4 Screw a full length dummy bracket to the OPA card and insert the OP...

Страница 82: ...http www tyan com 82 2 1 7 Installing the Mezzanine Card Follow these instructions to install the Mezzanine Card 1 Unscrew the dummy bracket 2 Pull the dummy bracket to slide it out...

Страница 83: ...http www tyan com 83 3 Insert a Mezzanine card associated with tray into the slot and screw it to the chassis...

Страница 84: ...urteen 2 5 HDD SSD Follow these instructions to install a hard drive 1 Pull the HDD tray out from the chassis 2 Remove 4 screws to detach the HDD tray bracket 3 Place a HDD SSD into the drive tray Use...

Страница 85: ...ard Drives optional The B7109F77DV4HR 2T NF SKU supports four 3 5 2 5 HDD SSD Follow these instructions to install a hard drive 3 5 Hard Disk Drive 1 Push the latches to pull the HDD tray out 2 Adjust...

Страница 86: ...http www tyan com 86 3 Place a 3 5 HDD into the HDD tray 4 Reinsert the HDD tray into the chassis...

Страница 87: ...tp www tyan com 87 2 5 Hard Disk Drive 1 Adjusting the 4 HDD locks to the 2 5 location 2 Secure the 2 standoffs to the 2 5 HDD 3 Insert the HDD into the HDD tray 4 Reinsert the HDD tray into the chass...

Страница 88: ...et x 2 Mounting Ears x 2 Screw Sack x 2 NOTE The users have to prepare two screws and two nuts on their own for rack mounting 2 2 1 Installing the Server in a Rack Follow these instructions to mount t...

Страница 89: ...Screw the mounting ear to each side of FT77D B7109 as shown using 4 screws from the supplied screws kit 2 Press the latch key to draw out the inner rails from sliding rails 3 Secure inner rails to bot...

Страница 90: ...http www tyan com 90 4 Secure the screws to both sides of the chassis...

Страница 91: ...http www tyan com 91 2 2 3 Installing the Outer Rails to the Rack 1 Please note to prepare two nuts and two screws before you start the work 2 Secure the outer rails to the rack...

Страница 92: ...http www tyan com 92 2 2 4 Rack mounting the Server 1 Lift the chassis and then insert the inner slide rails into the outer rails 2 Push the chassis in 3 Screw the mounting ears of chassis to the rack...

Страница 93: ...http www tyan com 93 4 Press the latch keys on both sides simultaneously to pull the system out...

Страница 94: ...http www tyan com 94 NOTE...

Страница 95: ...S7109 Motherboard M1713F77C FPB Front Panel Board M1809F77A FB Fan Board M2215 L8 1F M2217 L16 IO Riser Card M1284F77D BP12E 14 M1291F77D BP12E 4 HDD Backplane Board M7109F77D D PBP Power Backplane B...

Страница 96: ...of FT77D B7109 3 4 Replacing the Power Supply To replace the power supply follow these instructions 1 Press the tab as shown to pull out the power 2 Free the power from the power cage 3 Replace a new...

Страница 97: ...n com 97 3 5 Replacing the Front Panel Board Follow these instructions to replace the M1713F77C FPB Front Panel Board 1 Disconnect the USB3 0 and Front Panel Cable 2 Unscrew to remove the front panel...

Страница 98: ...ree screws to take out the front panel board Remove the ID Button cap LED sponge and LED Lens to reinstall in the new Front Panel Board 4 Follow the steps described earlier in reverse order to reinsta...

Страница 99: ...cifications SSI 24 pin front panel I O connector to MB 1 20 pin front panel USB3 0 connector to MB BTN PWR BTN w LED Reset BTN ID BTN NMI BTN LED PWR LED green Warning LED amber ID LED blue HDD LED gr...

Страница 100: ...http www tyan com 100 3 6 Replacing the Fan Board Follow these instructions to replace the M1809F77A FB Fan Board 1 Remove all Fan modules 2 Unscrew the fan cage 3 Lift up the fan cage...

Страница 101: ...http www tyan com 101 4 Disconnect all cables from the Fan Board 5 Unscrew to replace with a new Fan Board Follow the steps in reverse order to reinstall the Fan Board...

Страница 102: ...3 6 1 Fan Board Features M1809F77A FB Fan Board Specifications Support 6 120x38 mm system FAN 4 4 pin B4P RA PWR Connector run DC 12V 6 4 pin Hot swap FAN Connector 1 20 pin barebone system FAN connec...

Страница 103: ...BP12E 14 Follow these instructions to replace the M1284F77D BP12E 14 HDD Backplane Board 1 Remove the screws on both sides of the chassis 2 Remove all HDD trays from the HDD cage 3 Refer to Section 3...

Страница 104: ...http www tyan com 104 4 Unscrew the Front COM and VGA Ports 5 Disconnect the COM and VGA cables 6 Unscrew to release the HDD Cage...

Страница 105: ...http www tyan com 105 7 Lift up the HDD cage from the chassis 8 Disconnect all cables connected to the HDD BP Board NVME SKU R SATA SKU R NVME SATA SKU L...

Страница 106: ...yan com 106 9 Unscrew the HDD BP Board from the chassis 10 Take out the HDD BP Board to replace with a new one Follow the procedures described earlier in reverse order to reinstall the HDD BP Board an...

Страница 107: ...2E 4 Follow these instructions to replace the M1291F77D BP12E 4 HDD Backplane Board This HDD BP Board is pre installed for B7109F77DV4HR 2T NF only 1 Remove the screws on both sides of the chassis 2 R...

Страница 108: ...n com 108 3 Refer to Section 3 5 Replacing the Front Panel Board to take out the Front Panel Board Tray 4 Unscrew the Front COM and VGA Ports 5 Disconnect the COM and VGA cables 6 Unscrew to release t...

Страница 109: ...age from the chassis 8 Disconnect all cables connected to the HDD BP Board and loosen 4 screws to lift up the HDD BP Board for replacement 9 Follow the procedures described earlier in reverse order to...

Страница 110: ...port 14 hot swappable 2 5 HDD SSD or NVMe SSD speed up to 12Gb s Onboard HDD LED indication for HDD status Active Status 3 B4P HDD PWR Connector 2 7 pin SATA Connector 3 Mini SAS HD Connector 2 SFF 86...

Страница 111: ...ed up to SATA 6G s SAS 12G s NVMe 8G s Onboard HDD LED indication for HDD status Active Status 2 B4P HDD power connector PW1 PW2 2 OCULink connector J1 J2 1 Mini SAS HD connector SATA0_3 4 SFF 8639 co...

Страница 112: ...ce the M7059F77C D PDB Power Distribution Board 1 Disconnect the PWR cable Unscrew the M7059F77C D PDB Power Distribution Board 2 Remove the power distribution board for replacement 3 Follow the steps...

Страница 113: ...stribution Board Specifications 1 24S 6P RA Connector to M7109F77D D PBP 1 ATX 8 pin PWR Connector to Fan Board 16 ATX 8 pin PWR Connector to GPU card J3 J18 2x4pin ATX Power Connector for GPU the max...

Страница 114: ...3 9 Replacing the Riser Card Follow these instructions to replace the M2215 L8 1F Riser Card 1 Pull out all power supply units and unscrew the Mezz card module Unscrew the power supply cage 2 Unscrew...

Страница 115: ...n com 115 3 Lift up the power supply cage 4 Loosen the screws to lift up the bracket 5 Unscrew to replace a new riser card 6 Follow the steps described earlier in reverse order to reinstall the riser...

Страница 116: ...http www tyan com 116 3 9 1 Riser card Feature M2215 L8 1F Riser Card Form Factor W31 85 x L94 mm 4 layer PCB Specification 1 PCI E Gen3 x8 Slot for non standard add on card...

Страница 117: ...Card Follow these instructions to replace the M2217 L16 IO OCP Riser Card 1 Unscrew the M2217 L16 IO OCP Riser Card 2 Lift up to replace with a new OCP Riser Card 3 Follow the steps described earlier...

Страница 118: ...http www tyan com 118 3 10 1 OCP Riser Card Features Front View M2217 L16 IO OCP Riser Card Specifications PCIE x16 support 1 OCPA slot 1 OCPB slot...

Страница 119: ...o replace the M7109F77D D PBP Power Backplane Board 1 Unscrew the Power Backplane Board Tray 2 Lift up the PBP Board Tray 3 Unscrew the M7109F77D D PBP from the bracket and replace with a new one 4 Fo...

Страница 120: ...ane Board Features Front View Rear View M7109F77D D PBP Power Backplane Board Specifications 3 Power supply Connector for DPS 1600CB A DPS 2200AB 2 D 1 24S 6P RA Connector to MB 1 24S 6P Connector to...

Страница 121: ...3 12 Replacing the Motherboard After removing all of the aforementioned cables and components follow these instructions to remove the motherboard from the chassis 1 Loosen the screws securing the PDB...

Страница 122: ...he OCP Riser Card Bracket 3 Refer to Section 3 9 Replacing the Riser Card and 3 10 Replacing the Power Backplane Board to remove the Power Supply Cage and the PBP Tray 4 SATA SKU Disconnect all cables...

Страница 123: ...http www tyan com 123 6 Unscrew the motherboard to lift it up for replacement...

Страница 124: ...http www tyan com 124 NOTE...

Страница 125: ...st conditions MITAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the mother...

Страница 126: ...w tyan com 126 4 1 Board Image S7109GM2NR 2T This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above p...

Страница 127: ...http www tyan com 127 S7109GM2NR 8X 2T This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture...

Страница 128: ...http www tyan com 128 4 2 Block Diagram S7109 Block Diagram...

Страница 129: ...http www tyan com 129 4 3 Motherboard Mechanical Drawing...

Страница 130: ...sion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populati...

Страница 131: ...31 PSU12V Power Connector J45 11 FAN Header for BP FAN Board J29 32 PCH AUX PWR OK LED PCH_PWOK_LED1 12 Sideband Header HFI_HD1 33 Onboard HDD Active LED HDD_LED1 13 Sideband Header HFI_HD2 34 AST2500...

Страница 132: ...T J8 J9 J10 J11 J12 J13 J14 J15 R PCI E 3 0x8 slot open end type J25 J K L M N O P Q PCI E 3 0x8 slot x8 link open end type only for S7109GM2NR 8X 2T J16 J17 J18 J19 J20 J21 J22 J23 S PCI E 3 0x8 slot...

Страница 133: ...der open Pin 1 2 Signal Intrusion Switch Intrusion Switch GND Short Default Open Use this header to trigger the system chassis intrusion alarm Short Use this header to disable the system chassis intru...

Страница 134: ...r input11 15 16 SMB DATA Tachometer input12 17 18 SMB CLK 3 3V Standby 19 20 PWM output3 J31 IPMB Connector Signal Pin Pin Signal SMB_SDA2 1 2 GND SMB_SCL2 3 4 NC J44 Clear CMOS Jumper Normal Default...

Страница 135: ...J59 Vertical Type A USB Connector Pin 1 2 3 4 Signal USB 5V Power USB Data USB Data GND J56 J57 SATA2 0 Connector 7 1 1 GND Connects to the Serial ATA ready drives via the Serial ATA cable J56 SATA4 J...

Страница 136: ...RT5 J38 ME Recovery Mode Jumper Pin 1 2 Closed Normal Mode Default Pin 2 3 Closed ME In Force Update Mode J37J41 LPC Mode Jumper Pin 1 2 Closed System Reset Default Pin 2 3 Closed BMC Reset J47 VROC H...

Страница 137: ...7 DBG_HD1 TYAN Module Header TPM_Header Signal Pin Pin Signal P3V3 1 2 FRAME_N LAD0 3 4 KEY LAD1 5 6 PLT_RST_N LAD2 7 8 GND LAD3 9 10 CLK_33M DBG_SERIRQ 11 12 GND DBG_PRES_N 13 14 VCC3_AUX TPM_ADDR_MB...

Страница 138: ...o touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as the...

Страница 139: ...t simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard...

Страница 140: ...ad of metal Although the plastic studs are usable MITAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 141: ...motherboard This platform supports 12 12 DDR4 RDIMM RDIMM 3DS LRDIMM LRDIMM3DS 2666 DDR4 JEDEC NVDIMM 2666 Up to 768GB RDIMM 1 536GB LRDIMM 3 072GB RDIMM 3DS LRDIMM 3DS are supported 1 2V DDR4 DIMMs...

Страница 142: ...A1 P0_MC0_DIM_CH_B0 P0_MC0_DIM_CH_B1 P0_MC0_DIM_CH_C0 P0_MC0_DIM_CH_C1 P0_MC1_DIM_CH_D0 P0_MC1_DIM_CH_D1 P0_MC1_DIM_CH_E0 P0_MC1_DIM_CH_E1 P0_MC1_DIM_CH_F0 P0_MC1_DIM_CH_F1 P1_MC0_DIM_CH_A0 P1_MC0_DIM...

Страница 143: ...H_B0 P0_MC0_DIM_CH_B1 P0_MC0_DIM_CH_C0 P0_MC0_DIM_CH_C1 P0_MC1_DIM_CH_D0 P0_MC1_DIM_CH_D1 P0_MC1_DIM_CH_E0 P0_MC1_DIM_CH_E1 P0_MC1_DIM_CH_F0 P0_MC1_DIM_CH_F1 P1_MC0_DIM_CH_A0 P1_MC0_DIM_CH_A1 P1_MC0_D...

Страница 144: ...cates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM 4 Alwa...

Страница 145: ...http www tyan com 145 4 8 Mainboard LED Definition...

Страница 146: ...PCH is abnormal ON Amber The amber LED lights up when the power of PCH is normal CAT_LED1 CAT Error LED Pin Signal 3V GND State Description OFF OFF The LED shuts off when System is running normally ON...

Страница 147: ...F OFF The LED shuts off when the power of CPU1 is abnormal ON Green The LED lights up when the power of CPU1 is normally ATX_PG_LED1 PSU PWROK LED Pin Signal 3V GND State Description OFF OFF The LED s...

Страница 148: ...roperly especially SATA cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have expe...

Страница 149: ...and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program...

Страница 150: ...or best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 5 1 4 Setup Variations Not all systems have the same...

Страница 151: ...at can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Memory Information5 This displays the total memory size System Date Set the Date Use Tab t...

Страница 152: ...twork Stack Settings iSCSI Configuration Configure the iSCSI parameters Intel Virtual RAID on CPU This formset allows the user to manage Intel Virtual RAID on CPU Intel Optane DC persistent Memory Con...

Страница 153: ...on ROM Dispatch Policy PCI Subsystem Settings PCI PCI X and PCI Express Settings CSM Configuration CSM configuration Enable Disable Option ROM execution settings etc USB Configuration USB Configuratio...

Страница 154: ...When Network Stack is set to Enabled Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV PXE boot option will not be created Disabled Enabled Ipv4 HTTP Support Enable Ipv4 HTTP Boot Support...

Страница 155: ...6 HTTP boot option will not be created Disabled Enabled IPSEC Certificate Support to Enable Disable IPSEC certificate for Ikev Enabled Disabled PXE boot wait time Wait time to press ESC key to abort t...

Страница 156: ...function Step 1 Select Advanced CSM Configuration Network UEFI Step 2 Select Advanced Network Stack Configuration Network Stack Enabled Step 3 Save changes and reboot iSCSI Initiator Name The worldwi...

Страница 157: ...http www tyan com 157 5 3 2 1 Add an Attempt Read only NOTE Only LAN1 supports iSCSI function...

Страница 158: ...assigned in IP6 mode In Autoconfigure mode iSCSI driver will attempt to connect iSCSI target via IPv4 stack if failed then attempt IPv6 stack IP4 IP6 Autoconfigure Connection Retry Count The minimum v...

Страница 159: ...Mask Enter IP address in dotted decimal notation Gateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target Only iqn format is accepted iqu xxx Target IP A...

Страница 160: ...2 2 Delete Attempts Attempt 1 MAC 34 12 78 56 00 00 PFA Bus 1 Dev 0 Func 0 iSCSI mode Disabled IP version IP4 Disabled Enabled Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit...

Страница 161: ...Order Change the order of Attempts using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Attempt 1 Attempt Commit Changes and Exit Commit Ch...

Страница 162: ...MD for Volume Management Device on Socket 0 for CPU0 Socket 1 for CPU1 Intel VMD for Volume Management Device for PStack0 Slot 1 4 PStack1 Slot 5 8 PStack2 Slot 9 12 Step 2 Suppose the card is install...

Страница 163: ...http www tyan com 163 5 3 3 1 All Intel VMD Controllers Create RAID Volume This page allows you to create a RAID volume Non RAID Physical Disks Read only...

Страница 164: ...cial characters and is 16 characters or less Volume0 RAID Level Select RAID Level RAID0 Stripe Enable RAID spanned over VMD Controllers Enter RAID spanned over VMD Controllers blank X Port 0 VMD0 INTE...

Страница 165: ...MB Enter desired volume size Maximum size 763099 Create Volume Create a volume with the settings specified above NOTE For Create Volume to be configurable the following items Enable RAID spanned over...

Страница 166: ...http www tyan com 166 5 3 3 1 1 1 Create Volume Press y to create n to discard Volume0 RAID0 Stripe 708 0GB Normal Select to see more information about the RAID volume...

Страница 167: ...http www tyan com 167 5 3 3 1 1 1 1 Volume0 RAID0 Stripe 708 0GB Normal Read only...

Страница 168: ...http www tyan com 168 5 3 3 1 1 1 1 1 Delete Delete the RAID Volume Deleting a volume will reset the disks to non RAID Yes No...

Страница 169: ...http www tyan com 169 5 3 3 1 2 Port 0 VMD0 INTEL SSDPE2MD400G4 SN xxxx Port 1 VMD1 INTEL SSDPEDMD400G4 SN xxxx Read only...

Страница 170: ...IMMs Detected DIMMs 1 DIMMs View and configure installed DCPMMs Regions View and configure regions Namespaces Display create modify and delete namespaces Total Capacity Show total DCPMMs resource allo...

Страница 171: ...http www tyan com 171 Preferences View and or modify user preferences...

Страница 172: ...tails Monitor health Display DIMM health status and thresholds Update firmware Go to the update firmware page Configure security Go to the configure security page Configure data policy Go to the confi...

Страница 173: ...ils about the DIMM Disabled Enabled Monitor health Display DIMM health status and thresholds Update firmware Go to the update firmware page Configure security Go to the configure security page Configu...

Страница 174: ...r health Controller temperature C Controller temperature in Celsius 98 Media temperature C Media temperature in Celsius 82 Percentage remaining Percentage remaining 50 Apply changes Apply changes Back...

Страница 175: ...Update firmware File Please provide file path relative to the root directory of the device containg the new firmware For example firmware newFirmware bin Update Update the firmware verison Back to ma...

Страница 176: ...http www tyan com 176 5 3 4 1 4 Configure security State Disabled Enabled Back to main menu Return to the main menu...

Страница 177: ...p www tyan com 177 5 3 4 1 5 Configure data policy First fast refresh state Disabled Enabled Enable first fast refresh Enable acceleration of first fast refresh Back to main menu Return to the main me...

Страница 178: ...http www tyan com 178 5 3 4 2 Regions Region ID 1 View region details Create goal config Create goal configuration of DIMM regions Back to main menu Return to the main menu...

Страница 179: ...http www tyan com 179 5 3 4 2 1 Region ID 1 Back to Regions menu View and configure regions Back to main menu Return to the main menu...

Страница 180: ...ystem physical address space 0 Memory Mode Set the percentage of the total capacity to use in Memory Mode 0 100 Due to platform memory alignment requirements this value will be aligned automatically 0...

Страница 181: ...http www tyan com 181 Create goal config Create goal config on selected target Back to Regions menu View and configure regions Back to main menu Return to the main menu...

Страница 182: ...www tyan com 182 5 3 4 3 Namespaces 0x00000100 PmemDisk1 View details for or modify selected namespace Create namespace Create namespace with desired configuration Back to main menu Return to the main...

Страница 183: ...namespace Units Change the units of the namespace capacity B MB MiB GB GiB TB TiB Save Save configuration of current namespace Delete Delete current namespace Back to Namespaces Display create modify...

Страница 184: ...ace 0x0001 Mode Namespace Mode Sector Guarantees powerfail write atomicity via a block translation table BTT None Raw access only None Sector Capacity Input Use the maximum available capacity or enter...

Страница 185: ...http www tyan com 185 Create Namespace Create namespace using provided configuration Back to Namespaces Display create modify and delete namespaces Back to main menu Return to the main menu...

Страница 186: ...http www tyan com 186 5 3 4 4 Total Capacity Back to main menu Return to the main menu...

Страница 187: ...t Enabled Disabled DIMM ID 0x0001 DIMM to diagnose Enabled Disabled Config diagnostics Perform platform configuration diagnostics test Enabled Disabled FW diagnostics Perform firmware diagnostics test...

Страница 188: ...http www tyan com 188 Execute tests Execute selected diagnostic tests Back to main menu Return to the main menu...

Страница 189: ...http www tyan com 189 5 3 4 5 1 Execute tests Read only...

Страница 190: ...UID Capacity Units View modify the default units for displaying capacities Use Auto x1024 or Auto_10 x1000 to automatically select the best format Auto Auto_10 B MB MiB GB GiB TB TiB App Direct granul...

Страница 191: ...m 191 5 3 5 Trusted Computing Security Device Support Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available...

Страница 192: ...Enable ACPI Auto Configuration Enable or disable BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enable or disable System ability to Hibernate OS S4 Sleep State This option may not b...

Страница 193: ...Spread Spectrum Turn on off Spread Spectrum Setting of IsCLK Disabled Enabled Onboard Lan X550 Enable Disable onboard Lan X550 Disabled Enabled Chassis Intrusion detect ENABLED when a chassis open ev...

Страница 194: ...l to full speed automatic or manual Full Speed Automatic Manual NOTE PWM Minimal Duty Cycle menu is available when Auto Fan Control is set to Manual PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 BM...

Страница 195: ...http www tyan com 195 CRPS Support CRPS Support Disabled Enabled Number of PSU Number of PSU 1 1 1 2 1...

Страница 196: ...196 5 3 8 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE SDR can not be mo...

Страница 197: ...http www tyan com 197 5 3 9 AST2500 Super IO Configuration Super IO Chip Read only...

Страница 198: ...disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6...

Страница 199: ...d Select Dynamic Time system will wake on the current time increase minute s Disabled Fixed Time Dynamic Time When Wake system from S5 is set to Fixed Time Wake up hour Select 0 23 For example enter 3...

Страница 200: ...direction enable or disable Disabled Enabled COM1 Serial Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Settings The settings specify how the host computer which th...

Страница 201: ...ial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with th...

Страница 202: ...F8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode On this mode enabled only text will be sent This is to capture Terminal data Disable...

Страница 203: ...M1 Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST When Bootloader is selected then Legacy Console Redirection is disabled before booting t...

Страница 204: ...Server OS through a serial port COM1 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Sett...

Страница 205: ...g data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires...

Страница 206: ...atch Policy OnBoard LAN1 X550 Onboard Device has UEFI X Legacy X Emabed ROM s VIDx8086 DIDx1563 s0 Bx1 Dx0 Fx0 Enabled Disabled OnBoard LAN2 X550 Onboard Device has UEFI X Legacy X Emabed ROM s VIDx80...

Страница 207: ...or selected Slot Disabled Enabled Lan MEZZ Card Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled Storage Card Empty Enable or Disable Option ROM execution for selected S...

Страница 208: ...or Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe Devices this opt...

Страница 209: ...no USB devices are connected DISABLE option will keep USB devices available only for EFI applications Enabled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support Th...

Страница 210: ...e time out value for Control Bulk and Interrupt transfers 1 sec 5 sec 10 sec 20 sec Device reset time out USB mass storage device Start Unit command time out 10 sec 20 sec 30 sec 40 sec Device power u...

Страница 211: ...es Set display mode for Option ROM Force BIOS Keep Current Network Controls the execution of UEFI and Legacy PXE OpROM Legacy Do not launch UEFI Storage Controls the execution of UEFI and Legacy Stora...

Страница 212: ...http www tyan com 212 Other PCI Devices Determines OpROM execution policy for devices other than Network Storage or Video Legacy Do not launch UEFI...

Страница 213: ...http www tyan com 213 5 3 16 NVDIMM ADR Configuration Assert ADR on Reset Assert ADR on Reset Disabled Enabled Assert ADR on Shutdown Assert ADR on Shutdown Disabled Enabled...

Страница 214: ...U Registration Sign Up the current CPU This item support INTEL CPU sign the CPU will record current CPU Once BIOS checked different with registered CPU show WARNING message on POST screen Deregistrati...

Страница 215: ...215 5 3 18 Memory Registration Sign Up the current Memory Sign the Memory will record current Memory Once BIOS checked different with registered WARNING message on POST screen Deregistration Sign Up K...

Страница 216: ...http www tyan com 216 5 4 Platform Configuration PCH Configuration Displays and provides option to change the PCH Settings Server ME Configuration Configure Server ME Technology Parameters...

Страница 217: ...troller Hub devices PCI Express Configuration PCI Express Configuration settings PCH SATA Configuration SATA devices and settings PCH sSATA Configuration sSATA devices and settings USB Configuration U...

Страница 218: ...http www tyan com 218 5 4 1 1 PCH Devices Restore AC Power Loss Select S0 S5 for ACPI state after a G3 Power On Power Off Last State...

Страница 219: ...http www tyan com 219 5 4 1 2 PCI Express Configuration PCI Express Root Port 1 Port 20 PCI Express Root Port 1 Port 20 Settings...

Страница 220: ...press Root Port Disabled Enabled PCIE ASPM PCI Express Root port ASPM Setting Disabled ASPM ASPM L1 ASPM Auto L1 Substates PCI Express L1 Substates settings Disabled L1 1 L1 2 L1 1 L1 2 PCIe Speed Con...

Страница 221: ...Disable SATA Controller Enabled Disabled Configure SATA as Determines how SATA controller s operate AHCI RAID SATA Port 0 1 2 3 4 5 6 7 Software Preserve Read Only Port 0 Enable or Disable SATA Port D...

Страница 222: ...enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled Grading Power Up If enabled for any of ports Staggered Spin Up will be performed and only the drives which have this...

Страница 223: ...r Disable SATA Controller Enabled Disabled Configure sSATA as Determines how SATA controller s operate AHCI RAID sSATA Port 0 1 2 3 4 5 Software Preserve Read Only Port 0 Enable or Disable SATA Port D...

Страница 224: ...enabled for any of ports Staggered Spin Up will be performed and only the drives witch have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled sSATA Device...

Страница 225: ...225 5 4 1 5 USB Configuration XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect...

Страница 226: ...d ADR GPIO Select between GPIO_B or GPIO_C GPIO B GPIO C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Enabled Disabled Enable Disable ADR Timer Held off for DEBUG PURPO...

Страница 227: ...WDT Platform POR Enabled Disabled PMC Parity Error ADR Enable Enables Disables ADR on PMC Parity Error Platform POR Enabled Disabled ADR timer expire time Select proper ADR timer value 25uS 50uS 100uS...

Страница 228: ...http www tyan com 228 5 4 2 Miscellaneous Configuration Active Video Select active video type Onboard Device PCIE Device...

Страница 229: ...http www tyan com 229 5 4 3 Server ME Configuration Read only...

Страница 230: ...option to change the Common RefCode Settings UPI Configuration Displays and provides option to change the UPI Settings Memory Configuration Displays and provides option to change the Memory Settings...

Страница 231: ...isable Logical Processor threads Disabled Enabled Max CPUID Value Limit This should be enabled in order to boot legacy OSes that cannot support CPUs with extended CPUID functions Disabled Enabled Enab...

Страница 232: ...an com 232 Adjacent Cache Prefetch MLC Spatial Prefetcher MSR 1A4h Bit 1 Enabled Disabled Extended APCI Enable Disable extended APIC support Disabled Enabled AES NI Enable Disable AES NI support Enabl...

Страница 233: ...12M 1G 2G MMIO High Base Select MMIO High Base 56T 40T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up to 32xgranu...

Страница 234: ...http www tyan com 234 Numa Enable or Disable Non uniform Memory Access NUMA Disabled Enabled...

Страница 235: ...http www tyan com 235 5 5 3 UPI Configuration UPI General Configuration Displays and provides option to change the UPI General Settings...

Страница 236: ...ng the UPI Link Frequency 9 6GB s 10 4GB s Auto Use Per Link Setting Link L0p Enable Disabled Enable Auto Link L1 Enable Disabled Enable Auto SNC AUTO supports 1 cluster or 2 clusters depending on IMC...

Страница 237: ...http www tyan com 237 5 5 3 1 1 UPI Status Read only...

Страница 238: ...feature Auto Sets it to the MRC default setting current default is Enable Auto POR Disable Memory Frequency Maximum Memory Frequency Selections in Mhz Do not select Reserved Auto 2133 2400 2666 2933...

Страница 239: ...http www tyan com 239 Restore NVDIMMs Enables Disables Automatic restoring of NVDIMMs Disabled Enabled Interleave NVDIMMs Controls if NVDIMMs are interleaved together or not Disabled Enabled...

Страница 240: ...http www tyan com 240 5 5 4 1 Memory Topology Read only...

Страница 241: ...ode 1LM Mirror TAD0 Enable Mirror on entire memory for TAD0 Enabled Disabled Enable Partial Mirror Partial mirror mode will enable the required size of memory to be mirrored If rank sparing is enabled...

Страница 242: ...Memory Rack Sparing read only Enable Disable Memory Rank Sparing Disabled Enabled Correctable Error Threshold Correctable Error Threshold 1 32767 used for sparing tagging and leaky bucket 10 SDDC Plu...

Страница 243: ...D for Volume Management Device Configuration menu PCIe Hot Plug Enable Disable PCIe Hot Plug globally Disabled Enabled Auto Manual PCIe ACPI Hot Plug Enable Disable PCIe ACPI Hot Plug globally or allo...

Страница 244: ...http www tyan com 244 PCI E Completion Timeout Global Enable disable the Completion Timeout D x F 00 B8h B 4 where x is 0 3 Yes No Per Port...

Страница 245: ...x8 x16 Auto PCI E Completion Timeout Disable Enable disable the Completion Timeout D x F 00 B8h B 4 where x is 0 3 Yes No Socket 0 PcieBr2D00F0 Port 2A Settings related to PCI Express Ports 0 1A 1B 1C...

Страница 246: ...sed to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable This o...

Страница 247: ...B 256B Auto PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state D...

Страница 248: ...sed to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable This o...

Страница 249: ...CIe port A 6 0 dB 3 5 dB PCI E Port Max Payload Size Set Maxpayload size to 256B if possible 128B 256B Auto PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devic...

Страница 250: ...ifurcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 Auto PCI E Completion Timeout Disable Enable disable the Completion Timeout D x F 00 B8h B 4 where x is 0 3 Yes No Socket 1 PcieBr1D00F0...

Страница 251: ...sed to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable This o...

Страница 252: ...B 256B Auto PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state D...

Страница 253: ...signment to VMM through DMAR ACPI Tables Enabled Disabled NOTE When Intel VT for Directed I O VT d is set to Enabled the following items will be available PassThrough DMA Enable Disable Non Isoch VT_D...

Страница 254: ...http www tyan com 254 Coherency Support Non Isoch Enable Disable Non Isoch VT_D Engine Coherency support Enabled Disabled...

Страница 255: ...http www tyan com 255 5 5 5 4 Intel VMD Technology...

Страница 256: ...l Volume Management Device Technology in this Stack Disabled Enabled Intel VMD for Volume Management Device for PStack1 Enable Disable Intel Volume Management Device Technology in this Stack Disabled...

Страница 257: ...l Volume Management Device Technology in this Stack Disabled Enabled Intel VMD for Volume Management Device for PStack1 Enable Disable Intel Volume Management Device Technology in this Stack Disabled...

Страница 258: ...nagement Configuration CPU P State Control P State Control Configuration Sub Menu include Turbo XE and etc Hardware PM State Control Hardware P State setting CPU C State Control CPU C State setting Pa...

Страница 259: ...ce state that the BIOS will set before OS hand off Max Performance Max Efficient Set by Intel Node Energy Efficient Turbo Energy Efficient Turbo Disable MSR 0x1FC 19 Disabled Enabled Turbo Mode Enable...

Страница 260: ...http www tyan com 260 NOTE When CPU Flex Ratio Override is set to Enabled the following item is available CPU Core Flex Ratio Non Turbo Mode Processor Core Ratio Multiplier 23...

Страница 261: ...ates Disable Hardware choose a P state based on OS Request Legacy P States Native Mode Hardware choose a P state based on OS guidance Out of Band Mode Hardware autonomously choose a P state No OS guid...

Страница 262: ...PU C6 report Enable Disable CPU C6 ACPI C3 report to OS Auto Enable Disable Enhanced Halt State C1E Enables the Enhanced C1E state of the CPU takes effect after reboot Enabled Disabled OS ACPI Cx Repo...

Страница 263: ...http www tyan com 263 3 5 6 4 Package C State Control Package C State Control Package C State Limit C0 C1 state C2 state C6 non Retention state C6 Retention state No Limit Auto...

Страница 264: ...led FRB 2 Timer timeout and FRB 2 Timer Policy are read only FRB 2 Timer timeout Enter value Between 3 to 6 min for FRB 2 Timer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FRB 2 Timer Pol...

Страница 265: ...ad only OS Wtd Timer timeout Configure the length of the OS Boot Watchdog Timer Not available if OS Boot Watchdog timer is disabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Confi...

Страница 266: ...to Disabled the following items are read only Erase SEL Choose options for erasing SEL No Yes on next reset Yes on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing E...

Страница 267: ...http www tyan com 267 5 6 2 BMC Network Configuration...

Страница 268: ...Disable BMC Share Nic Enabled Disabled Configure IPV6 support Management Port 1 IPV6 Support Enable or Disable LAN1 IPV6 Support Enabled Disabled Configuration Address Source Select the configure LAN...

Страница 269: ...e Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm New Password window will...

Страница 270: ...t Mode Secure Boot mode selector Standard Custom In Custom mode Secure Boot Variables can be configured without authentication Standard Custom Restore Factory Keys Force System to User Mode Install fa...

Страница 271: ...Keys Force System to User Mode Install factory default Secure Boot key databases Press Yes to proceed No to cancel Reset to Setup Mode Delete all Secure Boot key database from NVRAM Deleting all varia...

Страница 272: ...ll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI P...

Страница 273: ...rnal Mixed Details Export Update Append Delete Authorized TimeStamps Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI...

Страница 274: ...0xFFFF means indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enable or disable Endless...

Страница 275: ...http www tyan com 275 Boot Option Priorities Boot Option 1 4 Sets the system boot order Device Name Disabled...

Страница 276: ...http www tyan com 276 5 8 1 Hard Drive BBS Priority Boot Option 1 2 Sets the system boot order Device Name Disabled...

Страница 277: ...New Boot Option Add boot option Specify name for new boot option Path for boot option Enter the path to the boot option in the format fsx path filename efi Boot option File Path Read only Create Creat...

Страница 278: ...http www tyan com 278 5 8 3 Delete Boot Option Delete Boot Option Remove an EFI boot option from the boot order Select one to delete UEFI Built in EFI Shell...

Страница 279: ...system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save chang...

Страница 280: ...Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Use...

Страница 281: ...6 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Страница 282: ...on up to BDS 0x90 0xCF BDS execution 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Sta...

Страница 283: ...tialization North Bridge module specific 0x17 Pre memory North Bridge initialization North Bridge module specific 0x18 Pre Memory North Bridge initialization North Bridge module specific 0x19 Pre memo...

Страница 284: ...Memory South Bridge initialization South Bridge module specific 0x3D Post Memory South Bridge initialization South Bridge module specific 0x3E Post Memory South Bridge initialization South Bridge modu...

Страница 285: ...gered by firmware Auto recovery 0xF1 Recovery condition triggered by user Forced recovery 0xF2 Recovery process started 0xF3 Recovery firmware image is found 0xF4 Recovery firmware image is loaded 0xF...

Страница 286: ...odule specific 0x6C North Bridge DXE initialization North Bridge module specific 0x6D North Bridge DXE initialization North Bridge module specific 0x6E North Bridge DXE initialization North Bridge mod...

Страница 287: ...vices connect 0x99 Super IO initialization 0x9A USB initialization is started 0x9B USB Reset 0x9C USB Detect 0x9D USB Enable 0x9E 0x9F Reserved for future AMI codes 0xA0 IDE initialization is started...

Страница 288: ...outh Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI resource allocation error Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6 No Console Outp...

Страница 289: ...is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state 0x10 System is waking up from the S1 sleep state 0x20 System is waking up from the S2 sleep st...

Страница 290: ...http www tyan com 290 NOTE...

Страница 291: ...nt shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the...

Страница 292: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion i...

Страница 293: ...ck1 CPU1 VMD Port 3A J10 J11 J18 J19 PStack1 CPU1 VMD Port 2A J8 J9 J16 J17 PStack0 corresponds to IOU0 PCIE PORT 1A1B1C1D PStack1 corresponds to IOU1 PCIE PORT 2A2B2C2D PStack2 corresponds to IOU2 PC...

Страница 294: ...http www tyan com 294 NOTE...

Страница 295: ...Wire Clip Follow these instructions to install the Power Wire Clip 1 Press the lever to pull the clip to the right 2 Insert the Power Wire Clip into the Power Wire Clip Jack 3 Plug in the AC Power Cor...

Страница 296: ...http www tyan com 296 NOTE...

Страница 297: ...Fan PWR Cable M1809F77A FAN board to M7059F77 PDB board Fan board Connect to PDB board J7 J2 J9 J10 J11 3 FP Ctrl USB Cable M1713 FP board to S7109 MB M1713 FP board Connect to S7109 M B J3_SSI_FP FP...

Страница 298: ...1 M B D4P_PW2 PW2 B4P PWR Cable 2 M B D4P_PW1 PW3 B4P PWR Cable 3 M B D4P_PW3 SGPIO1 SGPIO Cable SSATA_SGPIO1 6 B4P PWR Mini SAS HD SATA Cable For B7109F77DV14HR series M1284F77D HDD BP to S7109 MB HD...

Страница 299: ...MB HDD BP Connect to S7109 M B SATA0 3 Mini SAS HD Cable PCH_SSATA_0 3 PW1 B4P PWR Cable 1 M B D4P_PW1 PW2 B4P PWR Cable 2 M B D4P_PW2 9 2x3P 2x4P GPU PWR Cable M7059F77 PDB to GPU Card PDB Connect t...

Страница 300: ...http www tyan com 300 NOTE...

Страница 301: ...d A table of BIOS Temp sensor name explanation is also included for readers reference Figure 1 Sensor Location NOTE The red spot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is lo...

Страница 302: ...http www tyan com 302 BIOS Temp Sensor Name Explanation...

Страница 303: ...http www tyan com 303...

Страница 304: ...The Max Temperature of CPU0 DIMM A Slot P0_DIMM_CH_B_Max The Max Temperature of CPU0 DIMM B Slot P0_DIMM_CH_C_Max The Max Temperature of CPU0 DIMM C Slot P0_DIMM_CH_D_Max The Max Temperature of CPU0 D...

Страница 305: ...Core0 Slot GPU6_Core1_Temp Temperature of GPU6 Core1 Slot GPU7_Core0_Temp Temperature of GPU7 Core0 Slot GPU7_Core1_Temp Temperature of GPU7 Core1 Slot SYS_FAN_1 Fan speed of SYS_FAN_1 SYS_FAN_2 Fan...

Страница 306: ...http www tyan com 306 NOTE...

Страница 307: ...type For DPS 1600CB A CCBL 146H 422786600003 6 pin PCI E Power Cable CCBL 146I 422786600004 8 pin PCI E Power Cable FRU CS 0990 422T56800011 Dual 8 pin 2 3 2 1 PCI E Power Cable 250mm used for graphi...

Страница 308: ...I E x8 slot M2217 L16 IO 411T57700034 Riser Card M2217 L16 IO OCP Riser Card CPU Heat Sink FRU TH 0220 343T56600001 647 2U NARROW PASSIVE HEATSINK 1A0 D042800991 108 0X78 0X64 0MM SCREW FAN FRU TS 004...

Страница 309: ...r expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports...

Страница 310: ...oper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manuf...

Отзывы: