3.6      Replacing the USB Board 

 
Follow these instructions to replace the 

M1702T70-USB

 Board. 

 

1  Unscrew to release the USB front cover. 

   

 

2  Remove the USB front cover. 

     

 

Содержание Transport SX TN70E-B8026

Страница 1: ...TN70E B8026 Service Engineer s Manual...

Страница 2: ...ility or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without notice In...

Страница 3: ...re designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energ...

Страница 4: ...ncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Dispose of...

Страница 5: ...troduction to the TYAN TN70E B8026 barebones and standard parts list describes the external components gives an overview of the product from different angles Chapter 2 Setting Up This chapter covers p...

Страница 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Страница 7: ...nt Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is...

Страница 8: ...shock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety requi...

Страница 9: ...and back of the rack or remove the doors to ensure adequate air flow to the system If you install the Model in a rack do not place equipment on top of the unit It will cause restricted airflow and mig...

Страница 10: ...risk of fire and burns Do not disassemble crush puncture short external contacts or dispose of the battery in fire or water Do not expose the battery to temperatures higher than 60 C 140 F The system...

Страница 11: ...all watches rings or loose jewelry when working before removing covers and touching internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace...

Страница 12: ...e Air Duct 30 2 1 3 Installing the CPU and Heatsink 31 2 1 4 Installing the PCI E Card 34 2 1 5 Installing the Memory 37 2 1 6 Installing Hard Drives 39 2 2 Rack Mounting 46 2 2 1 Installing the Serve...

Страница 13: ...9 1 HDD Backplane Board Features 72 3 9 2 Connector Definition 73 3 10 Replacing the Power Distribution Board 74 3 11 Replacing the Rear HDD Backplane Board 75 3 11 1 HDD Backplane Features 76 3 11 2...

Страница 14: ...14 http www tyan com NOTE...

Страница 15: ...tation The TN70E B8026 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage TYAN also offers the TN70E B8026 in a version that can support up...

Страница 16: ...Hot Swap SSD HDD rear HDD Backplane Support SAS 12Gb s SATA 6Gb s NVMe Supported HDD Interface 8 SATA 6Gb s 4 NVMe Notification The SAS SATA HDD backplane is connected to onboard SATA connection by d...

Страница 17: ...card for 2 FH HL PCI E Gen3 x8 1 HH HL PCI E Gen3 x8 slots left 1 M7106 R24 3F riser card for 2 FH HL PCI E Gen3 x8 1 HH HL PCI E Gen3 x8 slots right Others 1 PCI E Gen3 x16 OCP 2 0 slot conn A conn...

Страница 18: ...dedicated for IPMI TPM Optional TPM Support Please refer to our TPM supported list System Monitoring Chipset Aspeed AST2500 Temperature Monitors temperature for CPU memory system environment Voltage...

Страница 19: ...oC Class A CB LVD Yes RCM Class A VCCI Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS...

Страница 20: ...e installed 8 60x38mm Fan pre installed 1 S8026GM2NRE MB 1 M1701T70 FPB Front Panel Board 1 M1702T70 USB USB Board 1 M1806G70 FB Fan Board 1 M1601T70E D PDB Power Distribution Board 1 M7106 R24 3F ris...

Страница 21: ...Product The following views show you the product 1 5 1 System Front View M1701T70 FPB Front Panel Board 1 Power Button with green LED 5 ID Button 2 IPMI LED 6 USB 2 0 Port 3 ID LED 7 USB 2 0 Port 4 R...

Страница 22: ...Amber Fan fail Over temperature Over Voltage PSU fail On Green No failure ID LED On Blue System identified remotely on the server by clicking the Chassis Locate LED key Off Off System not identified...

Страница 23: ...02 Series Processors deployed in all configurations Please contact Tyan Technical Support for more details ID LED LED State Color Description ID LED On Blue System identified Off Off System not identi...

Страница 24: ...LEDs to indicate LAN status The chart below illustrates the different LED states 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Right LED 10 Mbps Link Green Off Active Blinking Green Off 100 M...

Страница 25: ...25 http www tyan com 1 5 3 System Top View...

Страница 26: ...ane Board 3 8 System fans 4 M1601T70E D PDB Power Distribution Board 5 DELTA DPS 770GB C 770W Power Supply 6 2 Hot swap 2 5 SSD trays 7 Riser Card Bracket M7106 L24 3F M7106 R24 3F pre installed 8 Mem...

Страница 27: ...can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding s...

Страница 28: ...any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always plac...

Страница 29: ...components on to the mainboard including CPUs memory modules and add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove TN70E B8026 chassis cover 1 Remove the screw on the...

Страница 30: ...30 http www tyan com 2 1 2 Removing the Air Duct 1 Remove the air duct from the chassis...

Страница 31: ...en the screws securing the force frame in a sequential order 3 2 1 Note The force frame will automatically eject after the captive screws are being released 2 By placing your both index fingers on the...

Страница 32: ...ame with package into the slot on the rail frame Note During installation observe the following NOTE During installation observe the following 1 Make sure to push the carrier frame with package toward...

Страница 33: ...l frame firmly until it locks in place 7 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure the force frame in a sequential order 1 2 3 8 To secure the heatsink use...

Страница 34: ...34 http www tyan com 2 1 4 Installing the PCI E Card Follow these instructions to install the PCI E card 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis...

Страница 35: ...com 3 Unscrew to remove the dummy brackets 4 Insert the PCI E card into the riser card bracket and screw it firmly Follow the same procedures to insert the card to the other side of the riser card bra...

Страница 36: ...36 http www tyan com 5 The same procedure to install the PCIE card to the second riser card 6 Reposition and screw the riser card bracket into the chassis...

Страница 37: ...emory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly the memory slot locking levers lock autom...

Страница 38: ...38 http www tyan com Memory Population table...

Страница 39: ...Ds and two 2 5 hot swap SSDs Installing 3 5 Hot Swap Hard Drives Follow these instructions to install a 3 5 HDD Warning Always install the hard disk drive to the chassis after the chassis has been sec...

Страница 40: ...an com 40 3 Place the 3 5 hard disk drive into the HDD tray and secure the HDD to the HDD tray using 4 screws 4 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks...

Страница 41: ...rives Follow these instructions to install a 2 5 HDD SSD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and pu...

Страница 42: ...42 http www tyan com 3 Place the 2 5 HDD SSD into the HDD tray and align the 2 5 HDD SSD with its guide pins 4 Turn over the HDD tray and secure the HDD SSD to the tray using 4 screws...

Страница 43: ...43 http www tyan com 5 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks into place...

Страница 44: ...uctions to install a 2 5 SSD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and pull the locking lever open 2...

Страница 45: ...45 http www tyan com 4 Secure the other side HDD screws 5 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks into place...

Страница 46: ...g the Server in a Rack Follow these instructions to mount the TYAN TN70E B8026 into an industry standard 19 rack NOTE Before mounting the TYAN TN70E B8026 in a rack ensure that all internal components...

Страница 47: ...sis 1 Draw out the inner rail from the rail assembly When the rail comes to a stop pull the tab to release the latch and completely draw the inner rail out 2 Align the inner sliding rail on the side o...

Страница 48: ...e the sliding rail to the other side of the server Installing the Outer Rails to the Unit Secure the outer rails to the rack using four M5 screws and four washers A on each side Rack Mounting the Serv...

Страница 49: ...49 http www tyan com 2 When the inner rails come to a stop pull the tab to release the latch and push the whole system in 3 Secure the mounting ears of the unit to the rack using two M5 x 20L screws C...

Страница 50: ...50 http www tyan com NOTE...

Страница 51: ...ts including the Motherboard M1701T70 FP Front Panel Board M1702T70 USB Board M1290T70E BP12E 12 1 HDD Backplane M1287G88 BP12 2 HDD Backplane M1601T70 D PDB Power Distribution board M7106 L24 3F and...

Страница 52: ...cover of the TN70E B8026 3 4 Replacing Motherboard Components Follow these instructions to replace motherboard components including the motherboard 3 4 1 Replacing the Riser Card Follow these instruc...

Страница 53: ...com 3 Unscrew the M7016 L24 3F riser card to replace with a new one 4 Unscrew the M7016 R24 3F riser card to replace with a new one 5 Follow the steps described earlier in reverse to reinstall the ri...

Страница 54: ...ww tyan com 3 4 2 PCI E Riser Cards Specification M7106 L24 3F Riser Card 3 4 3 Connector Pin Definition M7106 L24 3F Location Definition J1 J2 J3 J4 PCIe X16 SLOT 4P Power Connector PCIe X8 SLOT PCIe...

Страница 55: ...com M7106 R24 3F Riser Card 3 4 4 Connector Pin Definition M7106 R24 3F Location Definition J1 J2 J3 J4 PCIe X8 SLOT 4Pin Power Connector PCIe X16 SLOT PCIe X8 SLOT J2 PWR1 Pin Signal Pin Signal 1 12V...

Страница 56: ...w tyan com 56 3 5 Replacing the Front Panel Board Follow these instructions to replace the M1701T70 FP Front Panel Board 1 Unscrew to release the Front Panel Board cover 2 Remove the Front Panel Board...

Страница 57: ...ww tyan com 57 3 Unscrew the Front Panel Board to replace a new one 4 Disconnect the Front Panel Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the Front Panel...

Страница 58: ...Connectors One 2x15 pin header for front panel connector of motherboard and HDD backplane board LEDs Power On Off LED Color Green after power on ID LED Color Blue Warning IPMI LED Dual Color Amber Wa...

Страница 59: ...failure ID LED On Blue System identified remotely on the server by clicking the Chassis Locate LED key Off Off System not identified J1 FPIO connector Definition Pin Pin Definition PW_LED 1 2 5VSB Ke...

Страница 60: ...http www tyan com 60 3 6 Replacing the USB Board Follow these instructions to replace the M1702T70 USB Board 1 Unscrew to release the USB front cover 2 Remove the USB front cover...

Страница 61: ...http www tyan com 61 3 Unscrew the USB Board 4 Disconnect the USB Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the USB Board...

Страница 62: ...rboard 2 USB ports 3 6 2 USB Board Connector Pin Definition J2 2x5 pin Connector for FP Connector of Motherboard Pin Definition Description Pin Definition Description 1 VCC_USB USB power 2 VCC_USB USB...

Страница 63: ...http www tyan com 63 3 7 Replacing the System Fan Follow these instructions to replace the fan 1 Disconnect the power cable 2 Press the button to take out the fan from the chassis...

Страница 64: ...64 http www tyan com 3 Release the rubber screws from the fan 4 Loose the screws on both sides 5 Push the latch in the direction as the arrow shown to release the fan from the iron holder...

Страница 65: ...65 http www tyan com 6 Remove the iron holder to replace a new fan 7 After replacing a new one put the fan unit back into the cage...

Страница 66: ...ww tyan com 3 8 Replacing the Fan Backplane Board Follow these instructions to replace the M1806G70 FB Fan Board in your system 1 Disconnect all the fan power cable 2 Use a screw driver to unscrew the...

Страница 67: ...http www tyan com 67 3 And lift it up from the chassis 4 Release the 14 screws on the Fan Backplane Board to replace a new one 5 Follow the steps described in reverse order to reinstall the fan cage...

Страница 68: ...Board in details Form Factor 254 mm x 82 mm 4 layer PCB Integrated I O 2 1x4pin R A Power Connector 8 2x2pin Fan Connectors 1 2x10pin Barebone Fan Connector 1 2x2pin Connector for S7086 3 8 2 Fan BP B...

Страница 69: ...n 12V 1 2 GND GND 3 4 5V Barebone Fan Connector J8 Definition Pin Pin Definition FANIN1 1 2 FANIN6 FANIN2 3 4 FANIN7 FANIN3 5 6 FANIN8 FANIN4 7 8 SIO_FANIN1 FANIN5 9 10 SIO_ FANIN2 GND 11 12 Key MB_PW...

Страница 70: ...re detach the HDD backplane please remove all the HDD trays with HDDs otherwise the HDD backplane will be damage when strains at the disassembly 1 Disconnect all cables connected to the M1290T70E BP12...

Страница 71: ...DD Backplane bracket 3 The HDD BP Board bracket is as shown below 4 Unscrew the backplane and replace with a new HDD backplane board 5 Follow the procedures described earlier to reinstall the HDD back...

Страница 72: ...1 HDD Backplane Board Features Front View Rear View Form Factor Dimension 422 4 29 8mm Specifications Overview 2 OCU Link Connector Input 3 Mini SAS HD Connector Input 4 SGPIO Header 12 SATA HDD or 8...

Страница 73: ...SATA8_11 NVME01 NVME23 PW1 SATA NVMe Connector SATA NVMe Connector SATA NVMe Connector SATA NVMe Connector SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector SATA Connector SA...

Страница 74: ...to replace the M1601T70E D PDB Power Distribution Board in your system 1 Disconnect all cables connected to the power distribution board 2 Unscrew to take off the power distribution board and replace...

Страница 75: ...http www tyan com 3 11 Replacing the Rear HDD Backplane Board Follow the instructions to replace the M1287G88 BP12 2 HDD backplane Board 1 Disconnect all cables and unscrew the power distribution boa...

Страница 76: ...layers Integrated I O 2 SATA Connectors 1 JTAG Jumper J1 1 SGPIO Connector J2 2 7 pin SATA connector 1 4 Pin Power connector The rear 2 SATA SSDs HDDs SATA0 SATA1 are not available when AMD EPYC 7002...

Страница 77: ..._5_RUN P8 P9 VDD_5_RUN HD0_PRS_L P10 P11 SAS0_LED GND P12 P13 HD0_V12HD VDD_5_RUN P14 P15 VDD_5_RUN GND S1 GND1 GND GND GND2 HDD1 HDD Connector Definition Pin Pin Definition SAS_TX1 S2 S3 SAS_TX1 GND...

Страница 78: ...SAS_RXBP1 GND 7 J1 JTAG Connector Definition Pin Pin Definition CPLD_JTAG_TCK 1 2 GND CPLD_JTAG_TDO 3 4 VDD_3P3_RUN CPLD_JTAG_TMS 5 6 NC NC 7 8 NC CPLD_JTAG_TDI 9 10 GND J2 SGPIO Connector Definition...

Страница 79: ...wer Supply Follow these instructions to replace the power supply module in your system 1 Press the latch to pull the power supply out 2 After replacing a new power supply press and hold the latch to p...

Страница 80: ...80 http www tyan com 3 13 Disconnecting All Motherboard Cables 1 Disconnect all cables connected to the motherboard...

Страница 81: ...of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the air duct processor and heatsink if installed 2 Remove nine screws securing the mothe...

Страница 82: ...82 http www tyan com NOTE...

Страница 83: ...Plate for OCP Card Follow these instructions to install the IO Plate for OCP Card Here shows how to install the IO Plate for the dual port LAN card M7062 I599 2T 1 Unscrew the riser card bracket 2 Re...

Страница 84: ...semi shearing for the OCP card slot Discharge the metal slug 4 Take out the IO plate for LAN card Use a screwdriver to break the LAN port s semi shearing Break one semi shearing if a single port LAN...

Страница 85: ...85 http www tyan com 5 Insert the IO Plate to the OCP card LAN port 6 Screw the IO Plate to the chassis...

Страница 86: ...86 http www tyan com 7 Insert the LAN card into the OCP slot 8 Secure the LAN card to the chassis...

Страница 87: ...TA 4 7 OCUL1 Mini SAS HD SATA 8 11 OCUL2 2 System FAN Ctrl cable FAN M1806G70 FB Connect to S8026 MB J8 FAN_HD1 3 Front Panel Control Cable Front Panel M1701T70 FPB Connect to S8026 MB J1 FPIO_2 4 Fro...

Страница 88: ...ply Cables M1601T70 D PDB Connect to M1287G88 BP12 2 1 Rear HDD BP J3 DVD PW1 9 SATA HDD Cable S8026 MB Connect to M1287G88 BP12 2 1 Rear HDD BP SSATADOM1 SSATA0 SSATADOM2 SSATA1 10 SGPIO Cable S8026...

Страница 89: ...he motherboard A table of BIOS Temp sensor name explanation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the...

Страница 90: ...90 http www tyan com NOTE The system temperature is measured in a scale defined by AMD not in Fahrenheit or Celsius BIOS Temp Sensor Name Explanation...

Страница 91: ...of CPU0 D1UMC0 channel A slot P0_D1_UMC1_CH_B The highest temperature of CPU0 D1 UMC1 channel B slot P0_D0_UMC1_CH_C The highest temperature of CPU0 D0 UMC1 channel C slot P0_D0_UMC0_CH_D The highest...

Страница 92: ...YS_FAN_4 SYS_FAN_5 Fan speed of SYS_FAN_5 SYS_FAN_6 Fan speed of SYS_FAN_6 SYS_FAN_7 Fan speed of SYS_FAN_7 SYS_FAN_8 Fan speed of SYS_FAN_8 SYS_FAN_9 Fan speed of SYS_FAN_9 SYS_FAN_10 Fan speed of SY...

Страница 93: ...For BB TYAN HDD BP FRU BP 9172 5412T5890003 TF PWA SBU TN70E B7106 M1290T70E B P12E 12 1 R02 FOR BB TYAN Rack Mounting CRAL 0170 340786900010 TF SLIDE RAIL MIC ASSY SBU YELLOW RIVER DP B7018Y190X2 Ca...

Страница 94: ...B7106 FRU CS 0890 332820000010 TF AC DC POWER CABLE SBU 18 AWG 200mm 2 4P PWR Y CABLE 2 4P M P4 2 2 4P M P4 2 2 4P M P4 2 TN70 B7016 FRU CS 0900 422T56700003 TF AC DC POWER CABLE SBU 24 AWG 350MM S4P...

Страница 95: ...s such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few...

Страница 96: ...oper maintenance of products Note A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manuf...

Отзывы: