background image

                                                       

http://www.tyan.com

 

41

3.2

   

 Replacing JBOD Components 

 
Follow these instructions to replace JBOD components, including the expander 
board, Front Panel Board, Power Distribution Board, fan module, and HDD 
Backplane Board. 
 

 

3.2.1   Replacing Expander Board 

 

Before replacing the expander board, remove cables connected to the 
expander board. Follow these instructions to remove all cables. 
 
1. 

Disconnect all cables.   

 

2. 

Remove the 4 screws securing the expander board to the chassis. 
Carefully lift the board from the chassis.     

 

 

3. 

Follow the procedures described earlier in reverse order to reinstall the 
expander board. 

 

 

Содержание TN70J-E3250

Страница 1: ...1 http www tyan com TN70J E3250 Service Engineer s Manual...

Страница 2: ...2 http www tyan com...

Страница 3: ...for accuracy and reliability prior to printing MiTAC assumes no liability whatsoever and disclaims any express or implied warranty relating to sale and or use of TYAN products including liability or...

Страница 4: ...les These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate rad...

Страница 5: ...hapter 2 Setting Up This chapter covers procedures on installing the hard drives and connecting the JBOD Expansion Chassis to HBA or RAID Subsystem and other optional parts Chapter 3 Replacing Compone...

Страница 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Страница 7: ...l hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space...

Страница 8: ...ock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety require...

Страница 9: ...Model in a rack do not place equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that...

Страница 10: ...ning hazardous energy levels Do not exceed the level of repair specified in the procedures in the product documentation Improper repairs can create a safety hazard Allow the product to cool before rem...

Страница 11: ...11 http www tyan com instructions...

Страница 12: ...http www tyan com 12...

Страница 13: ...ack 31 2 3 3 Rack mounting the Storage 32 2 4 Chassis Expansion 33 2 4 1 Single SAS in Out Port Configuration 33 2 4 2 Share Storage 2 SAS in Ports 35 2 4 3 Share Storage 3 SAS in Ports 35 2 4 4 IO Po...

Страница 14: ...1 4 2 3 Smart Fan Speed Control 62 4 2 4 SES elements status 62 4 2 5 Front Panel Warning LED Indication 65 4 2 6 SAS Link LED behavior 65 4 3 Upgrade Expander Firmware 67 4 3 1 FW utility Xutils from...

Страница 15: ...ness environment It provides a maximum data protection and exceptional performance in a storage subsystem Target usage ranges are set from small business to departmental and corporate server needs The...

Страница 16: ...Range 100 127V AC 5 5A 200 240V AC 3A Frequency 50 60 Hz Output Watts 450 Watts Expander Controller board Expander Controller LSI SAS 3X24R Connector 3 mini SAS HD connectors Connector configuration 1...

Страница 17: ...http www tyan com 17 RoHS RoHS 6 6 Compliant Yes Package Contains JBOD System TN70J E3250 JBOD System Manual 1 Web User s manual 1 Quick Installation Guide Installation CD 1 TYAN installation CD...

Страница 18: ...System Front View HDD Sequence HDD2 HDD5 HDD8 HDD11 HDD1 HDD4 HDD7 HDD10 HDD0 HDD3 HDD6 HDD9 No Description 1 12 2 5 3 5 hot swap HDD trays 2 Power Button with LED 3 Over temperature voltage PSU Fan s...

Страница 19: ...stem Off Off System works fine Power LED On Green System powered on Off Green System standing by Off Off System AC off HDD LED Definitions Drive State Activity LED Green color Status LED Orange color...

Страница 20: ...ear View No Description 1 1 1 450W hot swap Power Supply Unit 2 SAS Port Link LED 3 SAS Port Speed LED 4 SAS IN Port 0 5 SAS OUT Port 1 E 6 SAS OUT Port 2 E NOTE Please contact with TYAN technical sup...

Страница 21: ...ion 1 12 2 5 3 5 hot swap HDD trays 2 M1275T70B BP12 12 HDD Backplane Board 3 System Fans 4 M1601T70 D PDB Power Distribution Board 5 E3250 Expander Board 6 1 1 450W hot swap Power Supply Unit NOTE Th...

Страница 22: ...http www tyan com 22 NOTE...

Страница 23: ...0 2 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static pad Most of the electrical and mechanical conn...

Страница 24: ...onnectors and leads The expander board is pre installed in the system When removing the expander board always place it on a grounded anti static surface until you are ready to reinstall it Hold electr...

Страница 25: ...bays 1 1 hot swap 450W redundant Power Supply 2 System Fans 1 M1701T70 FPB 1 M1601T70 D PDB 1 M1806G70 Fan Board 1 M1275T70B BP12 12 HDD BP 2 1 2 Accessories If any items are missing or appear damaged...

Страница 26: ...2 Installing Hard Drives Follow these instructions to install 2 5 3 5 hard drives Warning Always install the hard disk drive to the chassis after the chassis is secured on the rack 1 Push the latch to...

Страница 27: ...http www tyan com 27 2 Option 1 2 5 HDD Place a 2 5 hard drive into the HDD tray and secure the HDD with 4 HDD screws 3 Option 2 3 5 HDD Unscrew the HDD tray...

Страница 28: ...http www tyan com 28 4 Place a 3 5 hard drive into the HDD tray Secure the HDD to the HDD tray with 5 screws 5 Reinsert the HDD tray into the chassis...

Страница 29: ...kit Rack mounting kit Sliding Rails x 2 Mounting Ears x 2 2 3 1 Installing the inner Rails to the Chassis Follow these instructions to mount the TYAN TN70J E3250 into an industry standard 19 rack NOTE...

Страница 30: ...http www tyan com 30 3 Pull the inner sliding rail forward to secure it to the chassis 4 Align the inner sliding rail on the other side of the chassis...

Страница 31: ...http www tyan com 31 2 3 2 Installing the Outer Rails to the Rack 1 Secure the outer rails to the rack...

Страница 32: ...tyan com 32 2 3 3 Rack mounting the Storage 1 Lift the unit and then insert the inner slide rails into the middle rails 2 Push the whole system into the rack 3 Secure the whole system to the rack with...

Страница 33: ...share storage or other IN OUT port configurations 2 4 1 Single SAS in Out Port Configuration Connection diagram A Connect one end of the External Mini SAS HD cable to the SAS OUT port on the Server an...

Страница 34: ...http www tyan com 34 Connection diagram volume expansion NOTE Maximum quantity of HDD that can be supported should be based on each type of HBA cards being used on server side...

Страница 35: ...http www tyan com 35 2 4 2 Share Storage 2 SAS in Ports 2 4 3 Share Storage 3 SAS in Ports...

Страница 36: ...http www tyan com 36 2 4 4 IO Port Connection...

Страница 37: ...e power switch of RAID system NOTE RAID controller is required for RAID support This step is to ensure users to understand the sequence of turning off machines when a RAID system is involved in config...

Страница 38: ...http www tyan com 38 NOTE...

Страница 39: ...This section is for the reference of the trained service technicians End users are not recommended to replace or remove components 3 1 Removing the Cover Before replacing any parts you must remove th...

Страница 40: ...http www tyan com 40 3 Unscrew the front top cover 4 Push the latches aside to loosen the top cover Remove the top cover from the chassis...

Страница 41: ...ackplane Board 3 2 1 Replacing Expander Board Before replacing the expander board remove cables connected to the expander board Follow these instructions to remove all cables 1 Disconnect all cables 2...

Страница 42: ...LSI SAS Expander 3x24R 3x36R EXT I O 2 Mini SAS HD IN 1 Mini SAS HD OUT Total support 10 Mini SAS HD Connector to HDD 1 E3250 1214E U8 3 Mini SAD HD connectors to 12 HDDs 2 E3250 2414E U8 6 Mini SAS H...

Страница 43: ...r J68 SSI_FP Connector J22 SAS0_0_3 Connector J23 SAS0_4_7 Connector J24 SAS0_8_11 Connector J37 EXT_A_IN_Connector J38 EXT_B_OUT Connector J40 EXT_C_OUT Connector Jumper Definition J3 TX J4 RX Mode S...

Страница 44: ...2 Replacing the Fans Follow these instructions to replace the fans 1 Press the latches to lift up the fan 2 Replace the failed fan module with a new one Follow the procedures described earlier in rev...

Страница 45: ...the Fan Backplane Board Follow these instructions to replace the Fan Backplane Board in your system 1 Disconnect the cables attached to the Fan Backplane Board 2 Use a screw drive to unscrew the fan...

Страница 46: ...http www tyan com 46 3 Release the 14 screws on the Fan Backplane Board to replace a new one 4 Follow the steps described in reverse order to reinstall the fan cage...

Страница 47: ...ctor 254 mm x 82 mm 4 layer PCB Integrated I O 2 1x4pin R A Power Connector 8 2x2pin Fan Connectors 1 2 x10pin Barebone Fan Connector 1 2x2pin Connector for S7015 3 2 3 2 Fan BP Board LED Definitions...

Страница 48: ...installed Power Supply Units Please unplug the power cord before you follow these instructions to replace the power supply units 1 Press the latch to pull the power supply out 2 After replacing a new...

Страница 49: ...ese instructions to replace the Power Distribution Board 1 Disconnect the cables on the power distribution board 2 Unscrew to lift up the power distribution board 3 Follow the steps described earlier...

Страница 50: ...ttp www tyan com 50 3 2 6 Replacing the HDD Backplane Board Follow these instructions to replace the HDD Backplane Board 1 Pull the power supply units out 2 Disconnect the cables 3 Unscrew the fan cag...

Страница 51: ...http www tyan com 51 4 Lift up the fan cage 5 Unplug all cables connected to the HDD BP Board...

Страница 52: ...http www tyan com 52 6 Unscrew the HDD BP Board 7 Release 7 push pins to lift the mylar 8 Reinstall the HDD BP Board into the chassis following the steps in reverse...

Страница 53: ...Backplane Board in details Front view Rear view Form Factor W436 x L82 mm 8 layer PCB Specifications 12 port SAS 12G SATA 6G 3 Mini SAS SATA SAS Connectors 1 2x4 pin power Connector 1 4 pin power conn...

Страница 54: ...54 3 2 6 2 Connector Pin Definitions PW1 8 pin Power Connector Pin 1 Pin 2 Pin 3 Pin 4 GND GND GND GND Pin 5 Pin 6 Pin 7 Pin 8 P12V P12V P12V P12V PW2 4 pin Power Connector Reserved Pin 1 2 3 4 Signal...

Страница 55: ...om 55 3 2 7 Replacing the Front Panel Board Follow these instructions to replace the Front Panel Board 1 Pull all HDD trays out 2 Unscrew the front panel bracket 3 Push the front panel bracket forward...

Страница 56: ...Unscrew to take out the front panel bezel 5 Unscrew the Front Panel Board FPB and disconnect the front panel cable to replace with a new FPB 4 Reinstall the Front Panel Board into the chassis followin...

Страница 57: ...tor 18 5MMx44 2MM 4 Layer PCB Connectors One 2x15 pin header for front panel connector of motherboard and HDD backplane board LEDs Power On Off LED Color Green after power on ID LED Color Blue Warning...

Страница 58: ...r Voltage PSU fail On Green No failure ID LED On Blue System identified Off Off System not identified J1 FPIO connector Definition Pin Pin Definition PW_LED 1 2 5VSB Key 3 4 ID_LED PW_LED 5 6 ID_LED H...

Страница 59: ...BA card to work with TN70J E3250 In addition user is advised to install management tool which is released by HBA providers and install it on the operating system in order to access the element status...

Страница 60: ...http www tyan com 60 For other configuration such as 3 SAS IN or 1 SAS OUT and 2 SAS IN or share storage configurations please contact Tyan technical support...

Страница 61: ...an function to change the fan speed base on the enclosure temperature Firmware continues monitoring voltage values temperature values power supply status and cooling RPM values When one or more below...

Страница 62: ...rotocol to set fan speed but the action isn t always success due to expander firmware would overwrite user s setting for the high temperature condition For example user may want to slow down fan speed...

Страница 63: ...ame in the table Please use SES nickname page to query them Here is the mapping table for reference 1 Temperature table Item Name 1 System Air Inlet sensor 2 MB Air Inlet sensor 3 Expander die tempera...

Страница 64: ...http www tyan com 64 And below figure shows where the elements are For array devices when the enclosure is linked with host and the array devices status will show up in Avago MSM utility...

Страница 65: ...termine which elements status has changed to alerting condition Please refer to chapter 4 2 4 For warning in Voltage status and Temperature status please contact our technical support For warning in F...

Страница 66: ...at certain level If the devices being used can support 12Gb s ex HBA and is operating in 12Gb s the Speed LED will show steady green If the devices being used can only support 3Gb s or 6Gb s or the de...

Страница 67: ...AS domain and their SAS address C Xutils windows g3Xutil exe i get avail g3Xutil LSI SAS Expander Utility Version 6 0 0 0 Copyright c 2014 LSI Corporation All rights reserved Initializing Interface WA...

Страница 68: ...own 2 Once SAS address is obtained please download new firmware to the target SAS address C Xutils windows g3Xutil exe i 500e0810000272bf down fw sas3xfw fw 1 g3Xutil LSI SAS Expander Utility Version...

Страница 69: ...ge is successful Are you sure to download file to expander y n y Downloading File Download Complete Post validating Post Validation of image is successful Download Successful 4 After firmware and sett...

Страница 70: ...http www tyan com 70 NOTE...

Страница 71: ...450W PSU FAN CFAN 0330 336252012309 12000RPM 60 60 38MM 4PIN fan Rack Mounting Parts CRAL 0170 340786900010 Slide Rail Kit Cable FRU CS 0330 332810000514 AC Power Cord US type L 1800mm CCBL 0300 3328...

Страница 72: ...http www tyan com 72 NOTE...

Страница 73: ...to and from computer storage devices such as hard drives and tape drives SES SCSI Enclosure Services Most SCSI enclosure products support this protocol Enclosure products can be communicated by using...

Страница 74: ...http www tyan com 74 NOTE...

Страница 75: ...ervice beyond their expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive com...

Страница 76: ...oper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manuf...

Отзывы: