background image

 

 

1

 

 

 

Tempest i5000VS 

/// 

S5372 

      Version 1.2a

 

 

 

Copyright 

Copyright © TYAN Computer Corporation, 2006. All rights reserved. No part of 
this manual may be reproduced or translated without prior written consent from 
TYAN Computer Corp. 
 

Trademark 

All registered and unregistered trademarks and company names contained in 
this manual are property of their respective owners including, but not limited to 
the following. 
 
TYAN, Tempest i5000VS are trademarks of TYAN Computer Corporation. 
Intel, Blackford-VS, and combinations thereof are trademarks of Intel 
Corporation. 
Phoenix, Phoenix-AwardBIOS are trademarks of Phoenix Technologies. 
 
 

Notice 

Information contained in this document is furnished by TYAN Computer 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
TYAN assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN products including liability or 
warranties relating to fitness for a particular purpose or merchantability. TYAN 
retains the right to make changes to product descriptions and/or specifications 
at any time, without notice. In no event will TYAN be held liable for any direct or 
indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document.

 

 
 

Содержание Tempest i5000VS S5372

Страница 1: ...rdBIOS are trademarks of Phoenix Technologies Notice Information contained in this document is furnished by TYAN Computer Corporation and has been reviewed for accuracy and reliability prior to printi...

Страница 2: ...s 23 2 6 Installing the Memory 26 2 7 Attaching Drive Cables 28 2 8 Installing Add in Cards 30 2 9 Connecting External Devices 31 2 10 Installing the Power Supply 32 2 11 Finishing up 32 Chapter 3 BI...

Страница 3: ...ial ATA power cable 6 x Serial ATA Cable 1 x USB2 0 cable 1x Serial Port Cable 1 x S5372 user s manual 1 x S5372 Quick Reference guide 1 x TYAN driver CD 1 x I O shield 2 x CPU Back Plane If any of th...

Страница 4: ...4...

Страница 5: ...ns Processors Dual LGA771 sockets Supports up to two 2 Intel R Xeon 5000 5100 series processors with 667 1066 1333 MHz FSB Supports up to two 2 Intel R Xeon 5300 series processors with1066 MHz FSB Chi...

Страница 6: ...ptional Tyan SMDC card Watchdog timer Port 80 code display LED BIOS PhoenixBIOS on 8Mbit Flash ROM Supports APM 1 2 ACPI 1 0 SATA activity LED connector Back Panel I O Ports Stacked PS 2 Mouse Keyboar...

Страница 7: ...7 Serial Console Redirect USB boot supported PnP DMI2 0 WfM2 0 power management Form Factor SSI CEB v1 01 footprint 12 0 x 10 5 305mm x 267mm Regulatory FCC Class B DoC CE DoC BSMI optional...

Страница 8: ...8 NOTE...

Страница 9: ...oard from the antistatic bag Unplug the power from your computer power supply and then touch a safely grounded object to release static charge i e power supply case For the safest conditions TYAN reco...

Страница 10: ...10 2 1 Board Image This picture is representative of the latest board revision available at the time of publishing The board you receive may or may not look exactly like the above picture...

Страница 11: ...11 2 2 Block Diagram Tempest i5000VS S5372 Block Diagram...

Страница 12: ...2 3 Board Parts Jumpers and Connectors This diagram is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagra...

Страница 13: ...truder Connector JP1 IPMB Connector JP2 JP3 ASF1 0 SMDC Select Header JP4 Clear CMOS Jumper CN1 CN2 ATX Power Connectors CN4 CN8 CPU Fan Connectors CN4 CPU0 Fan CN8 CPU1 Fan CN9 CN10 CN13 CN14 Chassis...

Страница 14: ...14 J1 Front NMI Connector 1 Use this header to connect with the front NMI output which indicates the status of BIOS NMI performance Pin 1 NMI Pin 2 VCC5 J1 J5 J4 J3 J2...

Страница 15: ...uder button which indicates the warning message when the system cover is opened Pin 1 Intruder Pin 2 GND J5 Rear Intruder Connector 1 Use this header to connect with the rear intruder button which ind...

Страница 16: ...16 JP1 IPMB Connector 1 Pin 1 IPMB DATA Pin 2 GND Pin 3 IPMB CLK Pin 4 NC JP4 CN15 JP1 CN12...

Страница 17: ...Pin_1 and 2 Reconnect power supply to AC source Power on system CN15 COM2 Header 1 9 2 10 Use these pin definitions to connect a port to COM2 TYAN does not provide cable for this header It is designe...

Страница 18: ...18 JP2 JP3 SMDC ASF1 0 Select Header 1 3 Support ASF1 0 3 1 Support SMDC card CN11 CN19 CN20 CN21 JP2 JP3...

Страница 19: ...The S5372 supports Tyan SMDC M3291 See Appendix I for more information on SMDC CN11 Tyan SO DIMM Connector Use this connector to connect the Tyan TARO card CN19 Front Panel Header The Front Panel Head...

Страница 20: ...PU0 Fan Connector 12V P WM G ND Tachometer Use this header to connect the processor cooling fan to your motherboard to keep the system at optimum performance levels CN8 CN4 SATA 0 1 2 3 4 5 CN9 CN10 C...

Страница 21: ...chassis cooling fan to your motherboard to keep the system at optimum performance levels CN 13 FAN3 CN9 FAN2 CN10 FAN1 CN14 FAN4 These fan connectors support tachometer monitoring and auto fan speed...

Страница 22: ...he motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard will not be ab...

Страница 23: ...as possible Follow these instructions to install your processor 1 Locate the processor socket on the motherboard and lift the protective cover off as shown WARNING This new processor socket designed...

Страница 24: ...4 Close the cover and return the locking lever to its locked position 5 Repeat this procedure for the second processor socket 6 Turn the board upside down and insert the heat sink spring mechanism as...

Страница 25: ...performance thermal compound to the top of the processor Try and apply a thin even layer over the top of the processor 2 Align the heatsink with the four holes around the processor socket 3 Press the...

Страница 26: ...533 FB DIMM Reg ECC memory modules are supported All installed memory will automatically be detected and no jumpers or settings need changing The Tempest i5000VS S5372 supports up to 16 24GB of memor...

Страница 27: ...e following illustration 2 Align the memory module with the socket The memory module is keyed to fit only one way in the socket 3 Seat the module firmly into the socket by gently pressing down until i...

Страница 28: ...er end s into the drive s Each standard IDE cable has three connectors two of which are closer together The BLUE connector that is furthest away from the other two is the end that connects to the moth...

Страница 29: ...floppy diskette drives are done in a similar manner to hard drives See the picture below for an example of a floppy cable Most of the current floppy drives on the market require that the cable be ins...

Страница 30: ...not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card PCI IDE...

Страница 31: ...finition The three onboard Ethernet ports have green and yellow LEDs to indicate LAN status The chart below illustrates the different LED states 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED...

Страница 32: ...let NOTE YOU MUST unplug the power supply before plugging the power cables to motherboard connectors 2 11 Finishing up Congratulations on making it this far You re finished setting up the hardware asp...

Страница 33: ...ly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are then stored in a dedicated battery backed m...

Страница 34: ...become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic look and function of the BIOS setup remains more or less the same for most...

Страница 35: ...ter X IDE Secondary Slave X Memory Cache X Boot Features System Memory Extended Memory xx xx xx xx xx xxxx xx xx xxxx 1 44 1 25 MB 3 None None None None xxxx KB xxxx KB Tab Shift Tab or Enter selects...

Страница 36: ...System Memory This display allows you to change the amount of system memory present on the system Extended Memory This displays allows you to change the amount of extended memory present on the syste...

Страница 37: ...this connection Auto autotypes hard disk drive installed here 1 39 you select pre determined type of hard disk drive installed here CD ROM a CD ROM drive is installed here ATAPI Removable removable d...

Страница 38: ...esults in a small performance increase Enabled Disabled Transfer Mode These modes determine the speed at which data is transferred to and from the drive The Auto option automatically determines the co...

Страница 39: ...10 Save and Exit Cache System BIOS Area This feature is only available when the system BIOS is shadowed It enables or disables the caching of the system BIOS ROM at F0000h FFFFFh via the L2 cache This...

Страница 40: ...nded Memory Area This feature allows you to control caching of system memory above one megabyte Uncached Write Back Write Through Write Protect Cache A000 AFFF B000 BFFF These features allow you to co...

Страница 41: ...ed will speed the boot process Disabled Enabled Keyboard Error Report This feature allows you to enable or disable the function of keyboard error report Disabled Enabled Summary Screen Enables or disa...

Страница 42: ...logo delays If disabled the BIOS will run the whole gamut of boot up tests It is recommended that you disable this feature when you boot up a new computer for the first time or whenever you install a...

Страница 43: ...g system to display unexpected behavior Win2K XP Other Reset Configuration Data If you install a new piece of hardware or modify your computer s hardware configuration the BIOS will automatically dete...

Страница 44: ...system Set this option to DOS if such a hard drive is present Else set this option to Other Virtually all modern hard disks have these characters so leave this option at DOS unless you know otherwise...

Страница 45: ...arallel ATA Serial ATA SATA Controller Mode Option Native Mode Operation Enable Single bit Auto 1 0GB Interleave Disabled Enabled Disabled Disabled 10 Min No Enabled Enabled Compatible Auto F1 Help Se...

Страница 46: ...AM UC error detection Enabled Disabled Force ITK Config Clocking This feature is used to enable disable FBD configuration for ITK test suite Enabled Disabled WatchDog Mode This feature allows you to e...

Страница 47: ...ity Power Boot Exit ICH USB Control Item Specific Help USB Device 29 All Function USB Device 29 F1 F2 and F3 USB Device 29 F2 and F3 USB Device 29 Function 7 Enabled Enabled Enabled Enabled F1 Help Se...

Страница 48: ...Setup Defaults Esc Exit Select Menu Enter Select X Sub Menu F10 Save and Exit PCI E Port 1 This feature is used to enable disabled the PCI E root port 3 3 1 3 Slot PCI E x8 Port Sub Menu These items a...

Страница 49: ...al Option ROM Scan LAN3 82551 Option ROM Scan Enabled Disabled Enabled Disabled Enabled Disabled F1 Help Select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select X Sub Menu F10 Sa...

Страница 50: ...Hyper Threading Technology provides thread level parallelism TLP on each processor resulting in increased utilization of processor execution resources As a result resource utilization yields higher pr...

Страница 51: ...abled Processor Power Management This feature is used to select the processor power management desired Disable C states and GV1 GV3 are disable GV1 GV3 only C states are disable Disabled GV1 GV3 only...

Страница 52: ...Security Power Boot Exit Hardware Monitor Item Specific Help XVoltage Monitoring XFan Control CPU0 Fan CPU1 Fan Front Fan1 Front Fan2 Rear Fan 3 Rear Fan 4 CPU 0 Temp PECI CPU 1 Temp PECI Ambient temp...

Страница 53: ...F1 Help Select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select X Sub Menu F10 Save and Exit 3 3 4 2 FAN Control Sub Menu PhoenixBIOS Setup Utility Main Advanced Security Power B...

Страница 54: ...the motherboard Disabled On board COM A On board COM B Baud Rate This feature is used to enable the specified baud rate 19 2K 300 1200 2400 9600 38 4K 57 6K 115 2K Console Type This feature is used to...

Страница 55: ...elect Menu Enter Select X Sub Menu F10 Save and Exit The system displays the current supervisor and user passwords Set Supervisor Password This option allows the supervisor to set the supervisor passw...

Страница 56: ...abled this allows the system to be worked up at a specified time This time is specified by the Resume Time parameter Off On Resume Time This option allows the user to specify the time when the system...

Страница 57: ...nds or collapses devices with a or Ctrl Enter expands all Shift 1 enables or disables a device and moves the device up or down n May move removable device between Hard Disk or Removable Disk d Remove...

Страница 58: ...ve your changes to CMOS F1 Help Select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select X Sub Menu F10 Save and Exit Exit Saving Changes This exits BIOS setup after saving the ch...

Страница 59: ...ed The most common type of error is a memory error Before contacting your vendor or TYAN Technical Support be sure that you note as much as you can about the beep code length and order that you experi...

Страница 60: ...l word during warm boot 4Bh QuietBoot start optional 13h Initialize PCI Bus Mastering devices 4Ch Shadow video BIOS ROM 14h Initialize keyboard controller 4Eh Display BIOS copyright notice 16h 1 2 2 3...

Страница 61: ...BAh Initialize DMI parameters 84h Detect and install external parallel ports BBh Initialize PnP Option ROMs 85h Initialize PC compatible PnP ISA devices BCh Clear parity checkers 86h Re initialize onb...

Страница 62: ...hardware interrupts E6h Checksum BIOS ROM 9Fh Determine number of ATA and SCSI drives E7h Go to BIOS A0h Set time of day E8h Set Huge Segment E9h Initialize Multi Processor F1h Initialize Run Time Clo...

Страница 63: ...etwork card or SCSI card SMDC does not require any hardware specific driver As long as a standby power comes into the system SMDC will begin looking after the system Tyan SMDC provides diversified met...

Страница 64: ...ntinue to function even if the system is not powered on How SMDC and TSO Work The brief descriptions below will help explain how these items function Agent a system with SMDC installed The SMDC is ins...

Страница 65: ...an diskette maker If you would like to boot from hard disk press 0 and Enter or just wait for 10 seconds to boot automatically from hard disk Boot from CD ISOLINUX 2 00 2002 10 25 Copyright C 1994 200...

Страница 66: ...Maker Example Chipset Driver Diskette 01 Microsoft Windows 2000 32 bit Diskette 02 Microsoft Windows XP 32 bit Diskette 03 Microsoft Windows XP 64bit Diskette 04 Microsoft Windows 2003 64 bit Back 5 F...

Страница 67: ...t in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth then also results in greater speed BBS BIOS B...

Страница 68: ...n jumpers jumpers and jumper pins are active when they are on or closed and inactive when they are off or open CMOS Complementary Metal Oxide Semiconductors chips that hold the basic startup informati...

Страница 69: ...n Data a format for storing information about Plug n Play devices in the system BIOS This information helps properly configure the system each time it boots Fault tolerance a term describing a system...

Страница 70: ...SA Industry Standard Architecture a slower 8 or 16 bit bus data pathway Latency the amount of time that one part of a system spends waiting for another part to catch up This is most common when the sy...

Страница 71: ...ther make up the Wired for Management 2 0 baseline specification PXE was designed to define a standard set of preboot protocol services within a client towards the goal of allowing networked based boo...

Страница 72: ...bank before opening the next Serial port called as such because it transmits the eight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted i...

Страница 73: ...er and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC controls the vertical scanning properties of the monitor ZCR Ze...

Страница 74: ...ler for help BEFORE calling TYAN 4 Check the TYAN user group alt comp periphs mainboard TYAN Returning Merchandise for Service During the warranty period contact your distributor or system vendor FIRS...

Страница 75: ...different from that of the receiver Consult the dealer on an experienced radio television technician for help Notice for Canada This apparatus complies with the Class B limits for radio interference...

Отзывы: