background image

 

http://www.tyan.com

 

 

 

 

S8032 

 Version 1.0a

 

 
Copyright 

Copyright © 2020 MiTAC International Corporation. All rights reserved. No part of 
this manual may be reproduced or translated without prior written consent from 
MiTAC International Corporation. 

 

Trademark 

All registered and unregistered trademarks and company names contained in this 
manual are property of their respective owners including, but not limited to the 
following. 

 

TYAN

®

 is a trademark of MiTAC International Corporation. 

AMD

®

 is a trademark of AMD

®

 Corporation. 

AMI, AMI BIOS are trademarks of AMI Technologies. 
Microsoft

®

, Windows

®

 are trademarks of Microsoft Corporation. 

Winbond

®

 is a trademark of Winbond Electronics Corporation. 

 
Notice 

Information contained in this document is furnished by MiTAC International 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
MiTAC assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN

®

 products including liability or 

warranties relating to fitness for a particular purpose or merchantability. MiTAC 
retains the right to make changes to product descriptions and/or specifications at 
any time, without notice. In no event will MiTAC be held liable for any direct or 
indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document. 
 
 

Содержание S8032

Страница 1: ...soft Corporation Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for accur...

Страница 2: ...ce Material 32 2 8 Tips on Installing Motherboard in Chassis 33 2 9 Installing the Memory 35 2 10 Attaching Drive Cables 38 2 11 Installing Add In Cards 39 2 12 Connecting External Devices 40 2 13 Ins...

Страница 3: ...oard x 1 SATA Single Cable x 2 Rear IO shielding x 3 1 x S8032 Quick Installation Guide M 2 Screw kit x2 IMPORTANT NOTE Sales samples may not come with any of the accessories listed above If you have...

Страница 4: ...re sets provide the S8032 with the power and flexibility to meet demanding requirements for today s IT environments Remember to visit the TYAN website at http www tyan com There you can find all the i...

Страница 5: ...ector U 2 8 SFF 8654 for 16 NVMe ports Graphic Connector type D Sub 15 pin Resolution Up to 1920x1200 Chipset Aspeed AST2500 Input Output USB 2 USB3 1 Gen 1 ports rear 1 USB3 0 Gen 1 port Type A 1 USB...

Страница 6: ...anagement controller BMC 10 100 1000 Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature Hardware Monitor SMBIOS 3 0 PnP Wake on LAN Boot from USB device PXE via LAN Storage Console Redirection AC...

Страница 7: ...com 7 Cable SATA 2 SATA signal cables 1 3 Software Specifications For the latest AST2500 User s Guide and OS operation system support please visit the Tyan s Web site at http www tyan com for the late...

Страница 8: ...onditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboar...

Страница 9: ...ww tyan com 9 2 1 Board Image S8032GM2NE ML This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pi...

Страница 10: ...http www tyan com 10 2 2 Block Diagram S8032 Block Diagram...

Страница 11: ...http www tyan com 11 2 3 Motherboard Mechanical Drawing...

Страница 12: ...ion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populatio...

Страница 13: ...n Connector SYS_FAN_5 38 NVME Hot Plug HDR_4 15 4 pin Fan Connector SYS_FAN_4 39 FAN Header FAN_HD1 16 SATA Connector SATA4 40 Front Panel Header FPIO_2 17 SATA Connector SATA3 41 PSMI Header PSMI_HD1...

Страница 14: ...SET LAD2 7 8 GND LAD3 9 10 CLK DBG_SERIRQ 11 12 GND DBG_PRES_N 13 14 3VSB NA 15 16 TPM_PP_EN COM2 Serial Port Header Signal Pin Pin Signal DCD 1 2 DSR SIN 3 4 RTS SOUT 5 6 CTS DTR 7 8 RI GND 9 10 KEY...

Страница 15: ...Connector Signal Pin Pin Signal 5V 1 2 USB2 0_DATA_N USB2 0_DATA_P 3 4 GND USB3 0_RX_N 5 6 USB3 0_RX_P GND 7 8 USB3 0_TX_N USB3 0_TX_P 9 USB3_FPIO1 Front USB3 1 Header Signal Pin Pin Signal USB3_VCC_...

Страница 16: ...LK SMB_DAT SMB_ALERT GND V3P3 HDT1 HDT Header Signal Pin Pin Signal P1V8_AUX 1 2 TCK GND 3 4 TMS GND 5 6 TDI GND 7 8 TDO TRST_N 9 10 PEROK NC 11 12 RESET_N NC 13 14 NC NC 15 16 DBREQ_N GND 17 18 NC P1...

Страница 17: ...9 20 INTRUSION SYS_Air_Inlet 21 22 LAN2LED FP_NMI_BTN_N 23 24 LAN2LED PWR_BTN1 POWER Button Pin 1 2 3 4 Signal GND GND PWR_BTN1 PWR_BTN1 RST_BTN1 COLD Reset Button Pin 1 2 3 4 Signal GND GND FP_RST_BT...

Страница 18: ...mode for SlimSAS 1 2 sideband signal must set the jumper to 1 3 and 2 4 pin close J190 J191 COM2_SEL1 COM2_SEL2 Jumper Signal Pin Pin Signal BMC_RXD2 BMC_TXD2 1 2 TXD_OUT RXD_OUT BMC_TXD5 BMC_RXD5 3...

Страница 19: ..._RUN J194 CMOS Clear Jumper Normal Default Pin 1 2 3 Signal Vbat P0_Vddbt_Rtc_G GND 1 2 Normal RTC Reset DEFAULT 2 3 Clear RTC Registers You can reset the CMOS settings by using this jumper This can b...

Страница 20: ...14 NVME0_TX_P2 A15 NVME0_RX_P2 B15 NVME0_TX_N2 A16 GND B16 GND A17 NVME0_RX_N3 B17 NVME0_TX_P3 A18 NVME0_RX_P3 B18 NVME0_TX_N3 A19 GND B19 GND A20 NVME1_RX_N0 B20 NVME1_TX_P0 A21 NVME1_RX_P0 B21 NVME1...

Страница 21: ...D B23 CPU0_PCIE_G1_PESLOT2_TX_N13_C A24 GND B24 CPU0_PCIE_G1_PESLOT2_TX_P13_C A25 CPU0_PCIE_G1_PESLOT2_RX_P13 B25 GND A26 CPU0_PCIE_G1_PESLOT2_RX_N13 B26 GND A27 GND B27 CPU0_PCIE_G1_PESLOT2_TX_N12_C...

Страница 22: ..._N3 B69 GND A70 GND B70 CPU0_PCIE_G1_PESLOT2_TX_N2_C A71 GND B71 CPU0_PCIE_G1_PESLOT2_TX_P2_C A72 CPU0_PCIE_G1_PESLOT2_RX_P2 B72 GND A73 CPU0_PCIE_G1_PESLOT2_RX_N2 B73 GND A74 GND B74 CPU0_PCIE_G1_PES...

Страница 23: ...2_TX_N16_C A111 GND B111 GND A112 P0_SFP_SMBUS_DATA B112 PE1_SMB2_SCK A113 P0_SFP_SMBUS_CLK B113 PE1_SMB2_SDA A114 GND B114 VDD_12_RUN A115 VDD_12_RUN B115 VDD_12_RUN PESLOT2 Connector pin net pin net...

Страница 24: ...1_TX_N7_C A47 CPU0_PCIE_G3_PESLOT1_RX_N7 B47 GND A48 CPU0_PCIE_G3_PESLOT1_RX_P7 B48 NG A49 GND B49 GND A50 NG B50 CPU0_PCIE_G3_PESLOT1_TX_P8_C A51 GND B51 CPU0_PCIE_G3_PESLOT1_TX_N8_C A52 CPU0_PCIE_G3...

Страница 25: ...ESLOT2_RX_N18 B94 CPU0_PCIE_G2_PESLOT2_TX_P18_C A95 CPU0_PCIE_G2_PESLOT2_RX_P18 B95 CPU0_PCIE_G2_PESLOT2_TX_N18_C A96 GND B96 GND A97 CPU0_PCIE_G2_PESLOT2_RX_N19 B97 CPU0_PCIE_G2_PESLOT2_TX_P19_C A98...

Страница 26: ...tate Description OFF OFF The LED shuts off when the BMC controller cannot be detected or properly initiated Blinking Green The LED blinks per second to indicate that the BMC controller is working norm...

Страница 27: ...eps below to install the processors and heat sinks Please note that the illustrations are based on socket which may not look exactly like the motherboard you purchased Therefore the illustrations shou...

Страница 28: ...the rail frame Note During installation observe the following make sure to push the carrier frame with package towards the end of the rail frame until it clicks in place do not drop the carrier frame...

Страница 29: ...e rail frame with the installed package Then push both edges of the rail frame firmly until it locks in place 7 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure th...

Страница 30: ...seconds enter thermal protection and shut down if heatsinks are not installed Caution Take caution of the air flow must be in the direction which paralleled with memories For the safest method of inst...

Страница 31: ...http www tyan com 31 3 Connect the heatsink power cable to the mainboard connector...

Страница 32: ...touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as ther...

Страница 33: ...simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard w...

Страница 34: ...ad of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 35: ...you have is compatible with the motherboard and processor Check the TYAN Web site at http www tyan com for details of the type of memory recommended for your motherboard Support 16 DIMM slots support...

Страница 36: ...4_CH_H1 NOTE 1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ra...

Страница 37: ...ock a DIMM socket by Press the retaining clip outwardly in the following illustration 2 Align the memory module with the socket such that the DIMM NOTCH match the KEY SLOT on the socket 3 Seat the mod...

Страница 38: ...owing illustrates how to make a SATA Cable connection If you are in need of SATA SAS cables or power adapters please contact your local sales representative 1 SATA drive cable connection 2 SATA drive...

Страница 39: ...rt the card firmly Do not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and th...

Страница 40: ...com 5720 chipset Onboard LAN LED Color Definition The Three 3 onboard Ethernet ports have green and Amber LEDs to indicate LAN status The chart below illustrates the different LED states 1Gbps LAN Lin...

Страница 41: ...12VA1 GND 2 6 12VA1 GND 3 7 12VA1 GND 4 8 12VA1 2 14 Finishing Up Congratulations on making it this far You have finished setting up the hardware aspect of your computer Before closing up your chassis...

Страница 42: ...to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are...

Страница 43: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Страница 44: ...that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Product Name It displays Product information BIOS Version It displays BIOS version info...

Страница 45: ...Date Set the Date Use Tab to switch between Date elements Default Ranges Year 2005 2099 Months 1 12 Days dependent on month System Time Adjust the system clock HH 24 hours format MM Minutes SS Second...

Страница 46: ...Configuration CPU Configuration parameters Onboard Device Configuration Onboard Device and Function Configuration PCIE Slot Configuration Onboard PCIE Slot Configuration Trusted Computing Trusted Comp...

Страница 47: ...uration Network Stack Settings CSM Configuration CSM Configuration Enable Disable Option ROM execution setting etc NVMe Configuration NVMe Device Options settings SATA Configuration SATA Device Inform...

Страница 48: ...tyan com 48 3 3 1 CPU Configuration SVM Mode Enable disable CPU virtualization Disabled Enabled SMEE Control secure memory encryption enable Disabled Enabled CPU 0 Information View Information related...

Страница 49: ...http www tyan com 49 3 3 1 1 CPU0 Information...

Страница 50: ...r external VGA support Onboard OffBoard LAN B5720 Enable Disable Onboard LAN Devices Disabled Enabled LAN2 OPROM Enable Disable Load Option ROM For Onboard LAN Disabled Enabled with PXE LAN3 OPROM Ena...

Страница 51: ...urcation SLIMSAS1 SATA SLIMSAS3 8 SLIMSAS1 SATA SLIMSAS3 x4x4 SLIMSAS1 SATA SLIMSAS3 x2x2x2x2 SLIMSAS1 x8 SLIMSAS3 x8 SLIMSAS1 x8 SLIMSAS3 x4x4 SLIMSAS1 x8 SLIMSAS3 x2x2x2x2 SLIMSAS1 x4x4 SLIMSAS3 x8...

Страница 52: ...4 SLIMSAS6 x8 SLIMSAS5 x4x4 SLIMSAS6 x4x4 SLIMSAS5 x4x4 SLIMSAS6 x2x2x2x2 SLIMSAS5 x2x2x2x2 SLIMSAS6 x8 SLIMSAS5 x2x2x2x2 SLIMSAS6 x4x4 SLIMSAS5 x2x2x2x2 SLIMSAS6 x2x2x2x2 x16 spanning SLIMSAS5 SLIMSA...

Страница 53: ...d Onboard PCIE Slot Link Speed Configuration Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Gen 4 16 GT s Riser L Middle Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen 1 2 5 GT s G...

Страница 54: ...ted Computing Security Device Support Enable or disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will n...

Страница 55: ...an com 55 3 3 5 ACPI Settings Enable ACPI Auto Configuration Enables or Disables BIOS ACPI Auto Configuration Disabled Enabled Lock Legacy Resources Enables or Disables Lock of Legacy Resources Disabl...

Страница 56: ...http www tyan com 56 3 3 6 Redfish Host Interface Settings Read Only...

Страница 57: ...ntrol to full speed automatic or manual Full Speed Manual NOTE When Auto Fan Control was set to Manual PWM Minimal Duty Cycle Item will appear PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 BMC Aler...

Страница 58: ...58 3 3 7 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be m...

Страница 59: ...http www tyan com 59...

Страница 60: ...http www tyan com 60...

Страница 61: ...tings Wake system from S5 Enable or disable system wake on alarm event Select Fixed time system will wake on the hr min sec specified Select Dynamic Time system will wake on the current time Increase...

Страница 62: ...puter which the user is using will exchange data Both computers should have the same or compatible settings NOTE Console Redirection Settings menu only appear when Console Redirection was set to Enabl...

Страница 63: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 9600 19200 38400 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with t...

Страница 64: ...to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Страница 65: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 9600 19200 38400 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with t...

Страница 66: ...to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Страница 67: ...esolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST when Bootloader is selected then Legacy Console Redirection is disabled before booting to le...

Страница 68: ...rver OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Se...

Страница 69: ...n sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses tw...

Страница 70: ...n Active Serial Port 1 View and Set Basic properties of the SIO Logical device Like IO Base IRQ Range DMA Channel and Device Mode Active Serial Port 2 View and Set Basic properties of the SIO Logical...

Страница 71: ...abled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 3 4 5...

Страница 72: ...abled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 2F8h IRQ 3 DMA IO 3F8h IRQ 3 4 5...

Страница 73: ...vices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe devices this option Enable or Disable Single...

Страница 74: ...oad of PCI Express Device or allow System BIOS to select the value Auto 128 Bytes 256 Bytes 512 Bytes Maximum Read Request Set Maximum Read Request Size of PCI Express Device or allow System BIOS to s...

Страница 75: ...bled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support...

Страница 76: ...sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller AUTO uses default value for a Root port it is 100 ms for a Hub port the delay is ta...

Страница 77: ...If disabled IPv6 PXE boot support will not be available Disabled Enabled IPv6 HTTP Support Enable Disable IPv6 HTTP boot support If disabled IPv6 HTTP boot support will not be available Disabled Enab...

Страница 78: ...Controls the execution of UEFI and legacy Network OpROM Do not launch UEFI legacy Storage Controls the execution of UEFI and legacy Storage OpROM Do not launch UEFI legacy Video Controls the executio...

Страница 79: ...http www tyan com 79 3 3 15 NVMe Configuration...

Страница 80: ...http www tyan com 80 3 3 16 SATA Configuration...

Страница 81: ...http www tyan com 81 3 3 17 Tls Auth Configuration Server CA Configuration Press Enter to configure Server CA...

Страница 82: ...http www tyan com 82 3 3 17 1 Tls Auth Configuration Enroll Cert Press Enter to enroll cert Delete Cert Press Enter to delete cert...

Страница 83: ...ert Configuration Enroll Cert Using File Enroll Cert Using File Cert GUID Input digit character in 11111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Commit Changes and Exit Discard C...

Страница 84: ...http www tyan com 84 3 3 17 1 2 Enroll Cert Configuration FEXXXXXX XXXX XXXX XXXX XXXXXXXXXX GUID for CERT Disabled Enabled...

Страница 85: ...ate the iSCSI function Step 1 Select Advanced CSM Configuration Network UEFI Step 2 Select Advanced Network Stack Configuration Network Stack Enabled Step 3 Save changes and reboot iSCSI Initiator Nam...

Страница 86: ...http www tyan com 86 3 3 18 1 Add an Attempt Read only...

Страница 87: ...ssigned in IP6 mode In Autoconfigure mode iSCSI driver will attempt to connect iSCSI target via IPv4 stack if failed then attempt IPv6 stack IPv4 IPv6 Autoconfigure Connection Retry Count The minimum...

Страница 88: ...ateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target Only iqn format is accepted Range is from 4 to 223 iqu xxx Target Address Enter Target address in...

Страница 89: ...ssigned in IP6 mode In Autoconfigure mode iSCSI driver will attempt to connect iSCSI target via IPv4 stack if failed then attempt IPv6 stack IPv4 IPv6 Autoconfigure Connection Retry Count The minimum...

Страница 90: ...ateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target Only iqn format is accepted Range is from 4 to 223 iqu xxx Target Address Enter Target address in...

Страница 91: ...4 Disabled Enabled Attempt 2 MAC 36 02 0B 83 D7 63 PFA Bus 35 Dev 0 Func 3 iSCSI mode Disabled IP version IPv4 Disabled Enabled Attempt 3 MAC 36 02 0B 83 D7 63 PFA Bus 35 Dev 0 Func 3 iSCSI mode Disab...

Страница 92: ...Change the order of Attempts using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Attempt 1 Attempt 2 Attempt 3 Commit Changes and Exit Com...

Страница 93: ...http www tyan com 93 3 3 19 VLAN Configuration MAC AA1FE25F6D22 Enter Configuration Press ENTER to enter configuration menu for VLAN configuration...

Страница 94: ...3 19 1 Enter Configuration VLAN ID VLAN ID of new VLAN or existing VLAN valid value is 0 4094 Priority 802 1Q Priority valid value is 0 7 Add VLAN Create a new VLAN or update existing VLAN Remove VLAN...

Страница 95: ...uccessfully or not Disabled Enabled Local IP Address Enter IP address in dotted decimal notation Example 162 168 10 12 Local NetMask Enter Netmask in dotted decimal notation Example 255 255 255 0 Loca...

Страница 96: ...http www tyan com 96 3 3 20 MAC AA1FE25F6D22 IPv6 Network Menu Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration...

Страница 97: ...ansmit Count The number of consecutive Neighbor Solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address Detectio...

Страница 98: ...http www tyan com 98 3 4 Chipset Menu North Bridge North Bridge Parameters...

Страница 99: ...http www tyan com 99 3 4 1 North Bridge Configuration Memory Configuration Memory Configuration Memory Information Total Memory xxxxx MB Socket 0 Configuration View Information related to Socket 0...

Страница 100: ...http www tyan com 100 3 4 1 1 Socket 0 Information...

Страница 101: ...http www tyan com 101 3 5 AMD CBS Menu...

Страница 102: ...ask deferred error interrupts from each bank Enabled Disabled Auto Core Performance Boost Disable CPB Disabled Auto Global C state Control Controls IO based C state generation and DF C states Disabled...

Страница 103: ...http www tyan com 103 3 5 1 1 Performance Submenu...

Страница 104: ...e selections to take effect Auto 2 CCDs 3 CCDs 4 CCDs 6 CCDs Core control Sets the number of Cores to be used Once this option has been used to remove any CCDs a POWER CYCLE is required in order for f...

Страница 105: ...05 3 5 1 2 Prefetcher Submenu L1 Stream HW Prefetcher Option to Enable Disable L1 Stream HW Prefetcher Disabled Enabled Auto L2 Stream HW Prefetcher Option to Enable Disable L2 Stream HW Prefetcher Di...

Страница 106: ...http www tyan com 106 3 5 2 DF Common Options Submenu...

Страница 107: ...be honored regardless of this setting Disabled Auto Memory interleaving size Controls the memory interleaving size The valid values are AUTO 256 bytes 512 bytes 1 kbytes or 2kbytes This determines the...

Страница 108: ...08 3 5 2 2 ACPI Submenu ACPI SRAT L3 Cache As NUMA Domain Enabled Each CCX in the system will be declared as a separate NUMA domain Disabled Memory Addressing NUMA nodes per socket will be declared Di...

Страница 109: ...http www tyan com 109 3 5 3 UMC Common Options Submenu...

Страница 110: ...http www tyan com 110 3 5 3 1 DDR4 Common Options Submenu...

Страница 111: ...http www tyan com 111 3 5 3 1 1 DRAM Time Configuration Submenu Overclock Memory Overclock Settings Auto Enabled...

Страница 112: ...http www tyan com 112 3 5 3 2 Security Options Submenu TSME Transparent SME Disabled Enabled Auto Data Scramble Data scrambling Disabled Enabled Auto...

Страница 113: ...apping Submenu Chipselect Interleaving Interleave memory blocks across the DRAM chip selects for node 0 Disabled Auto BankGroupSwap Bank Group Swap settings Disabled Enabled Auto BankGroupSwapAlt Alte...

Страница 114: ...http www tyan com 114 3 5 5 NVDIMM Submenu NVDIMM N Feature Disable NVDIMM N feature for memory margin tool Disabled Enabled...

Страница 115: ...R must be enabled for ACS enable to work Enabled Disabled Auto PCIe ARI Support Enables Alternative Routing IO Interpretation Disabled Enabled Auto Enable AER Cap Enables Advanced Error Reporting Capa...

Страница 116: ...to Use the fused TDP Manual User can set customized TDP TDP is used to define the RC thermal model only Manual Auto EfficiencyModeEn 0 use performance optimized CCLK DPM settings 1 use power efficienc...

Страница 117: ...IS mission mode 1 APBDIS 0 1 Auto DF Cstates Enable Enable DF C states Disable Disable DF C states Disabled Enabled Auto BoostFmaxEn Auto Use the default Fmax Manual User can set the boost Fmax Manual...

Страница 118: ...http www tyan com 118 3 5 7 1 AC Power LOSS Options Submenu Restore Ac Power Loss Select Ac Loss Control Method Power Off Power On Last State...

Страница 119: ...http www tyan com 119 3 5 7 2 FCH RAS Options Submenu Reset after sync flood Enable AB to forward downstream sync flood message to system controller Disabled Enabled Auto...

Страница 120: ...mer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FBR 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing R...

Страница 121: ...20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled Do Nothing Reset Power Down Power Cycl...

Страница 122: ...ed Disabled Erase SEL Choose options for erasing SEL No Yes on next reset No on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Delete Oldest Recor...

Страница 123: ...http www tyan com 123 3 6 2 BMC Network Configuration Submenu...

Страница 124: ...icBmcNonDhcp Management Port 2 Enable Disable BMC Share NIC Disabled Enabled Configure IPV6 support Management Port 1 IPV6 Support Enable or Disable LAN1 IPV6 Support Disabled Enabled Management Port...

Страница 125: ...http www tyan com 125 3 6 3 BMC User Configuration Submenu Add User Press Enter to Add a User Delete User Press Enter to Delete a User Change User Settings Press Enter to Change User Settings...

Страница 126: ...http www tyan com 126 3 6 3 1 BMC Add User Configuration Submenu User Name Enter BMC User Name...

Страница 127: ...http www tyan com 127 3 6 3 2 BMC Delete User Configuration Submenu User Name Enter BMC User Name...

Страница 128: ...http www tyan com 128 3 6 3 3 BMC Change User Configuration Submenu User Name Enter BMC User Name...

Страница 129: ...trator Password Set Administrator Password User Password Set User Password Security Frozen Mode Enable or disable HDD security freeze lock Disable to support secure erase function Disabled Enabled Sec...

Страница 130: ...ure Boot Mode Secure Boot mode options Standard or Custom In Custom mode Secure Boot Policy variable can be configured by a physically present user without full authentication Standard Custom NOTE Whe...

Страница 131: ...ult Secure Boot keys after the platform reset and while the System is in Setup mode Disabled Enabled Restore Factory Keys Force System to User Mode Install factory default Secure Boot key databases Re...

Страница 132: ...ates from a file 1 Public Key Certificate in a EFI_signature_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Autheticated UEFI Variable 3 EFI PE COFF Image SHA256 K...

Страница 133: ...or load certificates from a file 1 Public Key Certificate in a EFI_signature_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Autheticated UEFI Variable 3 EFI PE COF...

Страница 134: ...or load certificates from a file 1 Public Key Certificate in a EFI_signature_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Autheticated UEFI Variable 3 EFI PE COF...

Страница 135: ...waiting Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enabled or Disabled Endless boot Disabled Enabled Wa...

Страница 136: ...order Device Name Disabled Boot Option 2 Sets the system boot order Device Name Disabled Boot Option 3 Sets the system boot order Device Name Disabled Add New Boot Option Add a new EFI boot option to...

Страница 137: ...7 3 8 1 Add Boot Option Configuration Add boot option Specify name for new boot option Path for boot option Enter the path to the boot option in the format fs path filename efi Create Creates the newl...

Страница 138: ...http www tyan com 138 3 8 2 Delete Boot Option Configuration Delete Boot Option Remove an EFI boot option from the boot order Device Name Select one to Delete...

Страница 139: ...any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of th...

Страница 140: ...http www tyan com 140 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Device Name...

Страница 141: ...4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Страница 142: ...0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used P...

Страница 143: ...tion North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initializ...

Страница 144: ...odule specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE PIL is started PCI Error Codes 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory init...

Страница 145: ...ry capsule 0xFB 0xFF Reserved for future AMI error codes DXE Phase Status Code Description 0x60 DXE Core is started 0x61 NVRAM initialization 0x62 Installation of the South Bridge Runtime Services 0x6...

Страница 146: ...0x78 ACPI module initialization 0x79 CSM initialization 0x7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver c...

Страница 147: ...t reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization codes DXE Error Codes 0xD0 CPU initialization error 0xD1 North Bridge initialization error 0xD2 South...

Страница 148: ...tering S5 sleep state 0x10 System is waking up from the S1 sleep state 0x20 System is waking up from the S2 sleep state 0x30 System is waking up from the S3 sleep state 0x40 System is waking up from t...

Страница 149: ...anation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan...

Страница 150: ...http www tyan com 150 BIOS Temp Sensor Name Explanation...

Страница 151: ...http www tyan com 151...

Страница 152: ...nnel C slot P0_UMC0_CH_D The highest temperature of CPU0 UMC0 channel D slot P0_UMC0_CH_E The highest temperature of CPU0 UMC0 channel E slot P0_UMC1_CH_F The highest temperature of CPU0 UMC1 channel...

Страница 153: ...http www tyan com 153 NOTE...

Страница 154: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Страница 155: ...ight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on e...

Страница 156: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Страница 157: ...aster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data trans...

Страница 158: ...it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronou...

Страница 159: ...oard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC...

Страница 160: ...omprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system compon...

Страница 161: ...ed by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...