background image

 

 

 

 

S4992 

/// 

S4992 

      Version 1.0

 

 

 

Copyright 

Copyright © MiTAC International Corporation, 2008. All rights reserved. No part 
of this manual may be reproduced  
or translated without prior written consent from MiTAC International Corporation. 

 

Trademark 

All registered and unregistered trademarks and company names contained in 
this manual are property of their respective owners including, but not limited to 
the following. 

 

TYAN

®

, is trademarks of MiTAC International Corporation. 

 

AMD

®

 ,Opteron™, and combinations thereof are trademarks of AMD 

Corporation. 

 

AMI

®

, AMIBIOS

®

, and combinations thereof are trademarks of AMI 

Technologies. 

 

Microsoft

®

, Windows

®

 are trademarks of Microsoft Corporation. 

 

Nvidia

®

  and nForce

®

 are trademarks of Nvidia  Corporation. 

 

IBM

®

, PC

®

, AT

®

, PS/2

®

 are trademarks of IBM Corporation. 

 

Winbond

®

 is a trademark of Winbond Electronics Corporation. 

 

 

Notice 

Information contained in this document is furnished by MiTAC International 
Corporation and has been reviewed for accuracy and reliability prior to printing. 
MiTAC assumes no liability whatsoever, and disclaims any express or implied 
warranty, relating to sale and/or use of TYAN

®

 products including liability or 

warranties relating to fitness for a particular purpose or merchantability. MiTAC 
retains the right to make changes to product descriptions and/or specifications 
at any time, without notice. In no event will MiTAC be held liable for any direct 
or indirect, incidental or consequential damage, loss of use, loss of data or other 
malady resulting from errors or inaccuracies of information contained in this 
document.

Содержание S4992

Страница 1: ...rce are trademarks of Nvidia Corporation IBM PC AT PS 2 are trademarks of IBM Corporation Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is fur...

Страница 2: ......

Страница 3: ...emory 24 2 10 Attaching Drive Cables 27 2 11 Installing Add In Cards 28 2 12 Connecting External Devices 29 2 13 Installing the Power Supply 30 2 14 Finishing Up 32 Chapter 3 KVM over IP Server Manage...

Страница 4: ...Chapter 5 Diagnostics 129 5 1 Beep Codes 129 5 2 Flash Utility 129 5 3 AMIBIOS Post Code 130 Appendix How to Make a Driver Diskette 133 Glossary 135 Technical Support 141...

Страница 5: ...ollowing 1x S4992 Motherboard 6 x SATA Cable 4 x CPU Backplane 2 x SAS to Backplane Cable 1 x S4992 User s Manual 1 x S4992 Quick Reference Guide 1 x TYAN Driver CD 1 x I O Shield If any of these item...

Страница 6: ......

Страница 7: ...on Remember to visit TYAN s Website at http www TYAN com There you can find information on all of TYAN s products with FAQs online manuals and BIOS upgrades 1 2 Hardware Specifications Processors Four...

Страница 8: ...in LCM header Back Panel I O Connector Stacked connector for PS 2 keyboard and mouse Stacked connector for 2 USB 2 0 Stacked connector for VGA COM 3 RJ 45 connectors side by side Integrated Network Pr...

Страница 9: ...ouch a safely grounded object to release static charge i e power supply case For the safest conditions TYAN recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do no...

Страница 10: ...http www TYAN com 2 1 Board Image This picture is representative of the latest board revision available at the time of publishing The board you receive may or may not look exactly like the above pictu...

Страница 11: ...5 http www TYAN com 2 2 Block Diagram S4992 Block Diagram Note CPU1 is required to use PCI E PCI X under IO55...

Страница 12: ...P55 This diagram is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram But for the DIMM number please ref...

Страница 13: ...1 USB 2 0 Header J23 PCI X Mode Selection J29 BBU Fan Connector JP3 Clear CMOS JP6 LAN 2 Selection JP7 LAN 1 Selection JP8 XG21 VGA Enable Disable Jumper JP9 IPMB Pin Header JP4 JP24 PCI E configurati...

Страница 14: ...ng this jumper if you have forgotten your system setup password or need to clear system BIOS setting Power off system and disconnect both power connectors from the motherboard Put jumper cap back to P...

Страница 15: ...TYAN com J1 J3 J4 J5 J6 J7 J32 J34 J36 J37 4 pin fan connector Pin_1 Pin 1 2 3 4 Signal GND 12V TACH PWM NOTE When using the 3 pin fans you will have no auto fan functionality J6 J1 J4 J5 J7 J34 J32...

Страница 16: ...10 http www TYAN com J8 PSMI Header Pin_1 Pin 1 2 3 4 5 Signal SMBUS CLOCK SMBUS DATA RSVD NC GND VDD_3P 3_DUAL J8 J18 J9 J19...

Страница 17: ...11 12 RSVD J18 LCM Pin Header Signal Pin Pin Signal VCC_5_RUN 1 2 RXD KEY PIN 3 4 GND VCC_5_ALW 5 6 TXD Use this header to connect to the LCM module with system monitoring function J19 Front Panel He...

Страница 18: ...om J20 J21 USB Pin Header Signal Pin Pin Signal 5VPWR 1 2 5VPWR USB0 3 4 USB1 USB0 5 6 USB1 GND 7 8 GND KEY PIN 9 10 GND Use this header to connect to the USB devices via the provided USB cable J20 J2...

Страница 19: ...SYS1_TACH 1 2 SYS6_TACH SYS2_TACH 3 4 SYS7_TACH SYS3_TACH 5 6 SYS8_TACH SYS4_TACH 7 8 SYS9_TACH SYS5_TACH 9 10 SYS10_TACH GND 11 12 KEY PIN SYS2_PWM 13 14 CPUX_PWM SYS11_TACH 15 16 SYS13_TACH SYS12_T...

Страница 20: ...peed and slot 3 will be disabled If a x8 or lower card is installed on Slot 4 then the installed card will run at x8 or lower speed and slot 3 will be active and run at a maximum of x8 speeds Pins 2 3...

Страница 21: ...led on Slot 6 then the installed card will run at x8 or lower speed and slot 5 will be active and run at a maximum of x8 speeds Pins 2 3 If this jumper is set to pins 2 3 then both slot 5 and 6 will b...

Страница 22: ...16 http www TYAN com JP6 LAN2 Selection Pins 1 2 Default Enable LAN2 Pins 2 3 Disable LAN2 Pin_1 Pin 1 2 3 Signal LAN1 DIS_N 82571_LAN1 DIS_N GND JP6 JP7...

Страница 23: ...17 http www TYAN com JP7 LAN1 Selection Pins 1 2 Default Enable LAN1 Pins 2 3 Disable LAN1 Pin_1 Pin 1 2 3 Signal LAN0 DIS_N 82571_LAN0 DIS_N GND...

Страница 24: ...as a visual guide to help you install the socket processor and may not be an exact representation of the processor you have Step 1 Take off the CPU protection cap Step 2 Pull the CPU lever up to unloc...

Страница 25: ...or as long as you own them The overheated processor is dangerous to the motherboard For the safest method of installation and information on choosing the appropriate heat sink use heat sinks validated...

Страница 26: ...care not to touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred...

Страница 27: ...rocessor and socket attach the end wire of the fan which should already be attached to the heat sink to the motherboard The following diagram illustrates how to connect fans onto the motherboard Once...

Страница 28: ...uds are usually metal and are gold in color Usually the chassis manufacturer will pre install the support studs If you are unsure of stud placement simply lay the motherboard inside the chassis and al...

Страница 29: ...ad of metal Although the plastic studs are usable TYAN recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 30: ...ed But over 4 DIMM per CPU will cause the memory speed to clock down to a slower speed at 800MHz so you cannot have 800MHz when full load test All installed memory will automatically be detected and n...

Страница 31: ...9 A CPU1_DIMM10 B CPU1_DIMM11 A CPU1_DIMM12 B CPU1_DIMM13 A CPU1_DIMM14 B CPU1_DIMM15 A CPU1_DIMM16 B CPU2_DIMM17 A CPU2_DIMM18 B CPU2_DIMM19 A CPU2_DIMM20 B CPU2_DIMM21 A CPU2_DIMM22 B CPU2_DIMM23 A...

Страница 32: ...the locking levers in the direction shown in the following illustration 2 Align the memory module with the socket The memory module is keyed to fit only one way in the socket 3 Seat the module firmly...

Страница 33: ...no need to set Master Slave jumpers on SATA drives Please refer to FRU List for the related cables If you are in need of SATA SAS cables or power adapters please contact your place of purchase The fo...

Страница 34: ...t force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card TIP It s g...

Страница 35: ...ustrates the different LED states 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Right LED Link Green Off 10 Mbps Active Blinking Green Off Link Green Green 100 Mbps Active Blinking Green Gree...

Страница 36: ...0 http www TYAN com 2 13 Installing the Power Supply There are four power connectors on your S4992 S4992 supports EPS 12V 24 pin 2x8 pin 4 pin power supplies please use below combination J2 PW3 PW2 PW...

Страница 37: ...n Signal 3 3V 1 13 3 3V 3 3V 2 14 12V GND 3 15 GND 5V 4 16 PS_ON GND 5 17 GND 5V 6 18 GND GND 7 19 GND PWRGD 8 20 Reset 5VSB 9 21 5V 12V 10 22 5V 12V 11 23 5V 3 3V 12 24 GND We suggest using a 1000W o...

Страница 38: ...operly especially IDE cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have experi...

Страница 39: ...rocessor which runs embedded Linux to complete a variety of tasks There is flexibility to choose among Keyboard Controller Style KCS Intelligent Platform Management Bus IPMB and standard IPMI over LAN...

Страница 40: ...he records in DHCP server or use IPMI utility Of course if DHCP doesn t meet your requirement you can also use any IPMI software to configure its network interface Detail procedure is described in fol...

Страница 41: ...p www TYAN com During first login you will be required to change the password If login successfully you will be redirected to following page Click Console on top left corner you can open the remote co...

Страница 42: ...KVM over IP Sever Management uses a dedicated RJ45 LAN port on motherboard You may check Page27 You can also find the port position on board s illustration The connector need be connected to a 10 100M...

Страница 43: ...it IP address net mask and gateway address It s recommended to assign KVM over IP Sever Management a fixed IP address according to its MAC address You can find MAC address label on KVM over IP Sever...

Страница 44: ...serial console software on your computer The serial console software can be hyper terminal Windows or Kermit Linux configure the serial port with following setting Parameter Value Baud Rate 115200 Da...

Страница 45: ...ial console wait a while then you will be brought to a configuration environment 3 4 1 4 Configure Network Interface with other IPMI software You can use any IPMI software such as IPMITool and IPMIUti...

Страница 46: ...to screen co ordinates X Y This mode is very easy to track and most modern Windows versions XP 2000 2003 as well as Mac OS X use this This mode is also easiest for KVM over IP Sever Management to tra...

Страница 47: ...ement addresses this situation with an intelligent synchronization algorithm There are three mouse modes available on KVM over IP Sever Management Auto Mouse Speed The automatic mouse speed mode tries...

Страница 48: ...e a simple but common pointer shape In most cases the detection and synchronization of animated pointer shapes is likely to fail In general pointer shapes that change during the pointer detection proc...

Страница 49: ...ndow area The local mouse pointer will be hidden and the remote one can be controlled directly To leave this mode it is necessary to define a mouse hotkey in the Remote Console Settings Panel Press th...

Страница 50: ...agement setting to factory default Connect the power supply cable press ESC key then you will see prompt detail procedure refer to step in Configure Network Interface with Serial Console Type defaults...

Страница 51: ...the remote video console Video Console Control Bar Ctl Alt Delete Special button key to send the Control Alt Delete key combination to the remote system Virtual Disk Button to open the Virtual Disk Pa...

Страница 52: ...on host system 3 5 2 1 Floppy Image In following page you can specify Floppy Image to be emulated as Floppy Disk You can specify up to two images and the maximum file size is 1 44MB There re two step...

Страница 53: ...The server name or its IP address On Windows 95 98 and Windows ME do not specify the IP address but the server name NetBIOS Name Share name The name of the share to be used Path to image The path of...

Страница 54: ...e KVM over IP Sever Management may not be able to access the referenced image file properly leave the given file un mounted and will display an according error message instead So we recommend to state...

Страница 55: ...irected device On the other hand if the local operating system writes data to the redirected device the drive cache of the operating system of the remote host might contain older data This may confuse...

Страница 56: ...50 http www TYAN com 3 5 3 2 Monitor Sensors If you use the motherboard specified firmware you could get sensors reading in this page With factory default firmware this page will be empty...

Страница 57: ...51 http www TYAN com 3 5 3 3 System Event Log These logs are IPMI events They re different with KVM over IP Sever Management own system logs...

Страница 58: ...52 http www TYAN com 3 5 3 4 Alert Settings In this page you can configure the IPMI PEF settings include filters policies and destinations...

Страница 59: ...53 http www TYAN com 3 5 4 User Management 3 5 4 1 Change Password You can change your current user s password here...

Страница 60: ...gin name It must be at least four characters long Confirm password Confirmation of the password above Email address This is optional Mobile number This information may be optionally provided Role Each...

Страница 61: ...the permissions for each user or group You select the item user and or group from the drop down menu All changes you make then affect the permission set of the selected entity The user can only access...

Страница 62: ...and for which the changes will take effect Select the desired user from the selection box and press the button Update This will result in displaying the according user settings below Transmission Enc...

Страница 63: ...ike pictures have best results with 4 Bit 16 gray scales 1 Bit color depth black white should only be used for extremely slow network connections Remote Console Type Specifies which Remote Console Vie...

Страница 64: ...g this keystroke already Typical examples are Control Alt Delete on Windows and DOS that is always caught or the key sequence Control Backspace on Linux that can be used for terminating the X Server I...

Страница 65: ...ponding RELEASE packet When the network is slow then it takes too long for the RELEASE packet to arrive This might mislead KVM over IP Sever Management to replicate the key pressing this is like you h...

Страница 66: ...use settings on the host use an additional acceleration setting KVM over IP Sever Management will try to detect the acceleration and speed of the mouse during the mouse sync process Fixed mouse speed...

Страница 67: ...ease be careful Basic Network Settings IP auto configuration With this option you can define if the KVM over IP Sever Management should fetch its network settings from a DHCP or BOOTP server For DHCP...

Страница 68: ...ork Settings Remote Console and HTTPS port Port number at which the KVM over IP Sever Management Remote Console server and HTTPS server are listening If left empty the default value port 444 will be u...

Страница 69: ...Depending on your network connection you may select an according speed value for this interface To adjust the interface automatically choose auto detect default value If this selection results in misb...

Страница 70: ...64 http www TYAN com 3 5 6 2 Dynamic DNS A freely available Dynamic DNS service dyndns org can be used...

Страница 71: ...d by the Remote Console to transmit both the screen data to the administrator machine and keyboard and mouse data back to the host If set to Off no encryption will be used If set to Try the applet wil...

Страница 72: ...before it allows further logins This is useful for blocking automated hacking and cracking attempts Login Limitations You can specify if only a single user is allowed to login to the OPMA module at o...

Страница 73: ...Management cards by its user The certificate s underlying secret key is also used for securing the SSL handshake Hence this is a security risk but far better than no encryption at all However it is po...

Страница 74: ...ain name It is identical to the name that is used to access KVM over IP Sever Management with a web browser but without the prefix http In case the name given here and the actual network name differ t...

Страница 75: ...es Longer keys may result in slower response time of the OPMA module during connection establishment 3 5 6 5 USB Setting In some case OS and BIOS driver cannot handle USB emulation driver on KVM over...

Страница 76: ...me setting will not be persistent so you have to wait BIOS to adjust it again after KVM over IP Sever Management loses power for more than a few minutes Our motherboard BIOS will set its time to KVM o...

Страница 77: ...entication The other options allow you to specify an LDAP or a RADIUS Server to use for the login authentication These methods are very useful when you want to map users into specific groups which hav...

Страница 78: ...ist logging enabled To log events you may use the internal log list of the KVM over IP Sever Management To show the log list click on Event Log on the Maintenance page Since the KVM over IP Sever Mana...

Страница 79: ...ou have to specify a SMTP server that has to be reachable from the KVM over IP Sever Management card and that needs no authentication at all server ip port SNMP Logging enabled If this is activated KV...

Страница 80: ...anagement will reply to SNMP requests Hint If a community is left blank you cannot perform the according request E g if you want to disable the possibility to reset KVM over IP Sever Management via SN...

Страница 81: ...r IP Sever Management 3 5 7 Maintenance 3 5 7 1 Device Information In device information page you can get the firmware version and build number which will be useful to our technical support 3 5 7 2 Ev...

Страница 82: ...stall new functionality or special features Normally the factory default firmware is mother board independent If you want specified feature such as monitoring sensors you need update firmware First cl...

Страница 83: ...he currently running firmware and the version number of the uploaded firmware Pressing the button Update will store the new version and substitute the old one completely Firmware updating is very crit...

Страница 84: ...www TYAN com Thirdly after the firmware has been stored KVM over IP Sever Management will reset automatically After about one minute you will be redirected to the Login page and requested to login onc...

Страница 85: ...gement itself Resetting the card itself is mainly needed to activate a newly updated firmware It will close all current connections to the administration console and to the Remote Console The whole pr...

Страница 86: ...lity or application generic IPMI driver is needed Open IPMI driver on Linux KVM over IP Sever Management can use the Open IPMI driver in Linux Kernel modprobe ipmi_devintf modprobe ipmi_si If you use...

Страница 87: ...sure the cache settings are not set to something like never check for newer pages Otherwise KVM over IP Sever Management pages may be loaded from your browser cache and not from the card Login to KVM...

Страница 88: ...d in the video settings of KVM over IP Sever Management The local monitor displays video data but the remote screen remains blank If the Remote Console is connected look at the status line of the Remo...

Страница 89: ...mouse pointer while XP switches into stand by mode For SUN computers a USB keyboard does not work KVM over IP Sever Management emulates a USB keyboard If you attach a USB keyboard to your host two ke...

Страница 90: ...84 http www TYAN com...

Страница 91: ...t the time of print and are sub ject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic con...

Страница 92: ...4 5 In Case of Problems If you have trouble booting your computer after making and saving the changes with the BIOS setup program you can restart the com puter by holding the power button down until t...

Страница 93: ...it is highlighted in white Often a text message will accompany it BIOS Setup Utility Main Advanced PCI PnP Boot Security Chipset Exit System Overview AMIBIOS Version VX XX Build Date DD MM YY ID 0AAAA...

Страница 94: ...onfiguration APM Configuration Event Log Configuration Hardware Health Configuration Remote Access Configuration USB Configuration Configure CPU Select Screen Select Item Enter Go to Sub Screen F1 Gen...

Страница 95: ...XX AGESA Version X X X X Physical Count X Logical Count X Quad Core AMD Opteron tm Revision xxxx Cache L1 xxxx Cache L2 xxxx Cache L3 xxxx Speed xxxxMHZ NB Clk Able to change Freq uCode Patch Level GA...

Страница 96: ...isabled GART Error Reporting Enabled This option should remain disabled for normal operation The driver developer may enable it for the purpose of testing Enabled Secure Virtual Machine Mode Disabled...

Страница 97: ...tected Not Detected Not Detected Not Detected Not Detected Not Detected Disabled 35 Host Device While entering setup BIOS auto detects the presence of IDE devices This displays the status of auto dete...

Страница 98: ...ID BIOS Setup Utility Main Advanced PCI PnP Boot Security Chipset Exit RAID Setup nVidia RAID Function Disabled SATA0 Dev 5 Func0 SATA1 Dev 5 Func0 SATA2 Dev 5 Func1 SATA3 Dev 5 Func1 SATA4 Dev 5 Func...

Страница 99: ...ode if the device supports it and the device is not already formatted with LBA Mode disabled Disabled Disabled LBA Mode Auto Block Multi Sector Transfer Disabled Disabled The Data transfer from and to...

Страница 100: ...y formatted with LBA Mode disabled Disabled Disabled LBA Mode Auto Block Multi Sector Transfer Disabled Disabled The Data transfer from and to the device occurs one sector at a time Auto The Data tran...

Страница 101: ...abled Allows BIOS to enable or disable Floppy Controller Select Screen Select Item Change Option F1 General Help F10 Save and Exit ESC Exit Feature Option Description Configure Win627 Super I O Chipse...

Страница 102: ...ted option A description of the selected item appears on the right side of the screen The settings are described on this page The screen is shown below BIOS Setup Utility Main Advanced PCI PnP Boot Se...

Страница 103: ...Configuration ACPI v3 0 ACPI v2 0 ACPI Version Features ACPI v1 0 Set this value to allow or prevent the system to be complaint with the ACPI 2 0 specification Enabled ACPI APIC Support Disabled This...

Страница 104: ...PnP Boot Security Chipset Exit Chipset ACPI Configuration MCP55 ACPI HPET TABLE Enabled Select Screen Select Item Change Option F1 General Help F10 Save and Exit ESC Exit Feature Option Description C...

Страница 105: ...Mode Enabled Green PC Monitor Power State Standby Hard Disk Power Down Mode Enabled Hard Disk Time Out Minute Disabled Force Throttle Disabled Manual Throttle Ratio 50 System Thermal Disabled Thermal...

Страница 106: ...Power Down Mode Disabled Power Down Hard Disk in suspend Mode 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Hard Disk Time Out Minute Disabled Hard Disk Time Out in specified Minutes Enabled Force Throttle Dis...

Страница 107: ...RAM Use the up and down arrow keys to select an item Use the Plus and Minus keys to change the value of the selected option The settings are described on the following pages BIOS Setup Utility Main Ad...

Страница 108: ...n item Use the Plus and Minus keys to change the value of the selected option The settings are described on the following pages BIOS Setup Utility Main Advanced PCI PnP Boot Security Chipset Exit Hard...

Страница 109: ...V System 5V 5V Standby System 3 3V 3 3V Standby System 12V Battery Volt CPU0 Temp CPU1 Temp CPU2 Temp CPU3 Temp System Temp 1 System Temp 2 System Temp 3 System Temp 4 System Temp 5 System Temp 6 XXXX...

Страница 110: ...type Select Screen Select Item Change Field F1 General Help F10 Save and Exit ESC Exit Feature Option Description Configure Remote Access type and parameters Enabled Remote Access Disabled Enables re...

Страница 111: ...r Mode HiSpeed BIOS EHCI Hand Off Enabled USB Mass Storage Device Configuration Enables support for legacy USB Select Screen Select Item Change Option F1 General Help F10 Save and Exit ESC Exit Featur...

Страница 112: ...loppy Forced FDD Hard Disk Emulation Type CDROM If Auto USB devices less than 530MB will be emulated as Floppy and remaining as hard drive Forced FDD option can be used to force a HDD formatted drive...

Страница 113: ...e of the selected option The settings are described on the following pages BIOS Setup Utility Main Advanced PCI PnP Boot Security Chipset Exit Advanced PCI PnP Settings WARING Setting wrong values in...

Страница 114: ...takes over When set to higher values every PCI device can conduct transactions for a longer time and thus improve the effective PCI bandwidth Values in units of PCI clocks for PCI device latency timer...

Страница 115: ...ot Settings Configuration Use the up and down arrow keys to select an item Use the Plus and Minus keys to change the value of the selected option BIOS Setup Utility Main Advanced PCI PnP Boot Security...

Страница 116: ...isabled PS 2 Mouse Support Auto Selects support for PS 2 Mouse Enabled Keyboard Error Report Disabled Keyboard error report on event log Enabled Wait for F1 If Error Disabled Waits for F1 key to be pr...

Страница 117: ...xit Boot Device Priority 1st Boot Device 2nd Boot Device xx xxx xxxxx xxx xx xxx xxxxx xxx Specifies the boot sequence from the available devices A device enclosed in parenthesis has been disabled in...

Страница 118: ...Drive 2 nd Drive xx xxx xxxxx xxx xx xxx xxxxx xxx Specifies the boot sequence from the available devices Select Screen Select Item Change Option F1 General Help F10 Save and Exit ESC Exit Feature Opt...

Страница 119: ...Not Installed Change Supervisor Password Change User Password Boot Sector Virus Protection Disabled Install or change the password Select Screen Select Item Change Option F1 General Help F10 Save and...

Страница 120: ...X Configuration Menu Select a menu by highlighting it using the Arrow keys and pressing Enter The settings are described on the following pages BIOS Setup Utility Main Advanced PCI PnP Boot Security...

Страница 121: ...Trcd Row Precharge Time Trp Min Active RAS Tras RAS RAS Delay Trrd Row Cycle Trc Write Recover Time Twr XXX MHz XX X CLK X CLK X CLK X CLK XX CLK X CLK Select Screen Select Item Enter Go to Sub Scree...

Страница 122: ...e faster the DRAM performance Row Precharge Time Trp Read only This item controls the number of cycles for Row Address Strobe RAS to be allowed to precharge If insufficient time is allowed for the RAS...

Страница 123: ...up Utility Main Advanced PCI PnP Boot Security Chipset Exit Memory Configuration Bank Interleaving Channel interleaving Enable Clock to All DIMMs MemClk Tristate C3 ATLVID Memory Hole Remapping CS Spu...

Страница 124: ...clocks to DIMMs even memory slots are not populated Disabled MemClk Tristate C3 ATLVID Enabled Enable Disable MemClk Tri Stating during C3 and Alt VID Disabled Memory Hole Remapping Enabled Enable Mem...

Страница 125: ...Select Screen Select item Change Option F1 General Help F10 Save and Exit ESC Exit Feature Option Description ECC Configuration Disabled DRAM ECC Enable Enabled DRAM ECC allows hardware to report and...

Страница 126: ...ata Cache RAM to be corrected while idle Disabled 40ns 80ns 160ns 320ns 640ns 1 28us 2 56us 5 12us 10 2us 20 5us 41 0us 81 9us 163 8us 327 7us L3 Cache BG Scrub 655 4us Allows the L3 Data Cache RAM to...

Страница 127: ...nfiguration Memory Clock Mode Auto DRAM Timing Mode Auto Auto Limit Manual Select Screen Select item Change Option F1 General Help F10 Save and Exit ESC Exit Feature Option Description DRAM Timing Con...

Страница 128: ...r disable altogether Some OSes require valid GART for proper operation If AGP is present select appropriate option to ensure proper AGP operation Select Screen Select Item Change Option F1 General Hel...

Страница 129: ...vanced PCI PnP Boot Security Chipset Exit SouthBridge Chipset Configuration CPU LDT Spread Spectrum Center Spread PCIE Spread Spectrum Disabled SATA Spread Spectrum Disabled Primary Graphics Adapter P...

Страница 130: ...pread Spectrum Enabled Select SATA Spread Spectrum Mode PCI Express PCI Primary Graphics Adapter PCI PCI Express Set Primary Graphics Adapter Mode Enabled USB 1 1 Disabled Enable Disable USB 1 1 Contr...

Страница 131: ...NODE 1 HT Link Speed Link Speed Auto NODE 0 NODE 1 Link Width Link Width Auto Hyper Transport MCP55 Configuration Mcp55 SB to K8 CPU Freq Auto Disabled Mcp55 SB to K8 CPU Frequency 1000 MHz Mcp55 SB...

Страница 132: ...cp55 SB to K8 CPU Freq Auto Disabled MCP55 SB to K8 CPU Frequency Selection by CPU capability 200 400 600 800 1000 1200 1400 Mcp55 SB to K8 CPU Frequency 1600 MCP55 SB to K8 CPU Frequency Selection 4...

Страница 133: ...Use this option to exit setup utility and re boot All new selections you have made are stored into CMOS System will use the new settings to boot up Discard Changes and Exit Use this option to exit set...

Страница 134: ...128 http www TYAN com...

Страница 135: ...or is a memory error Before contacting your vendor or TYAN Technical Support be sure that you note as much as you can about the beep code length and order that you experience Also be ready with inform...

Страница 136: ...T1ChHandlerBlock 08 Initializes the CPU The BAT test is being done on KBC Program the keyboard controller command byte is being done after Auto detection of KB MS using AMI KB 5 0A Initializes the 804...

Страница 137: ...te and write contents of ESCD in NVRam 84 Log errors encountered during POST 85 Display errors to the user and gets the user response for error 87 Execute BIOS setup if needed requested 8C Late POST i...

Страница 138: ...132 http www TYAN com...

Страница 139: ...em to TYAN diskette maker If you would like to boot from hard disk press 0 and Enter or just wait for 10 seconds to boot automatically from hard disk Boot from CD ISOLINUX 2 00 2002 10 25 Copyright C...

Страница 140: ...e Maker Example Chipset Driver Diskette 01 Microsoft Windows 2000 32 bit Diskette 02 Microsoft Windows XP 32 bit Diskette 03 Microsoft Windows XP 64bit Diskette 04 Microsoft Windows 2003 64 bit Back 5...

Страница 141: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Страница 142: ...ngle wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on eight different wires at the same time that is in parallel form eight bits...

Страница 143: ...r type of the Printed Circuit Board PCB or motherboard The standard form factors are the AT and ATX Global timer onboard hardware timer such as the Real Time Clock RTC HDD stands for Hard Disk Drive a...

Страница 144: ...perate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data transfer modes used by IDE drives These modes use the CPU...

Страница 145: ...ng system SDRAM Synchronous Dynamic RAM called as such because it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the othe...

Страница 146: ...one port type can function as a serial parallel mouse keyboard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA...

Страница 147: ...as possible TYAN also ranks high for its commitment to fast and friendly customer support through email By offering plenty of options for users TYAN serves multiple market segments with the industry s...

Страница 148: ...a circuit different from that of the receiver Consult the dealer on an experienced radio television technician for help Notice for Canada This apparatus complies with the Class B limits for radio inte...

Отзывы: