RAID 

RAID 0/1/10/5 (Intel RST) 

Graphic 

Connector type 

D-Sub 15-pin 

Chipset 

Aspeed AST2400 

I/O Ports 

USB 

(4) ports (2 at front, 4 at rear) 

VGA 

(1) D-Sub 15-pin port 

RJ-45 

(2) ports 

System 
Monitoring 

Chipset 

Aspeed AST2400 

Voltage 

Monitors voltage for CPU, memory, chipset & 
power supply 

Temperature 

Monitors temperature for CPU & memory 

LED 

Over temperature warning indicator / Fan & PSU 
fail LED indicator 

Others 

Watchdog timer support 

Server 
Management   

Onboard Chipset 

Onboard Aspeed AST2400 

AST2400 IPMI Feature 

IPMI 2.0 compliant baseboard management 
controller (BMC) / Supports storage over IP and 
remote platform-flash / USB 2.0 virtual hub 

AST2400 iKVM 
Feature 

24-bit high quality video compression / 10/100 
Mb/s MAC interface 

BIOS 

Brand / ROM size 

16MB 

Feature 

SMBIOS 2.7/PnP/Wake on LAN / ACPI 3.0/PXE 
boot 

Operating System 

OS supported list 

Please refer to our Intel OS supported list. 

 

Regulation 

FCC (DoC) 

Class A 

CE (DoC) 

Yes 

Operating 
Environment   

Operating Temp. 

10° C ~ 35° C (50° F~ 95° F) 

Non-operating Temp. 

- 40° C ~ 70° C (-40° F ~ 158° F) 

In/Non-operating 
Humidity 

90%, non-condensing at 35° C 

RoHS 

RoHS 6/6 Compliant 

Yes 

Package Contains 

Barebone 

(1) FT77C-B7079 Barebone 

Manual 

(1) Quick Installation Guide 

Installation CD 

(1) TYAN installation CD 

Cable  Others 

(8) GPU power cables 

 

 
 
TYAN FT77CB7079  (B7079F77CV10HR-2T-N) 

 

System 

Form Factor 

4U Rackmount 

Gross Weight 

35 kg 

Chassis Model 

FT77C 

Dimension (D x W x H) 

30.31" x 17.24" x 6.93" (770 x 438 x 176mm) 

Содержание FT77CB7079

Страница 1: ...1 http www tyan com FT77CB7079 Service Engineer s Manual...

Страница 2: ...2 http www tyan com...

Страница 3: ...or warranties relating to fitness for a particular purpose or merchantability TYAN retains the right to make changes to produce descriptions and or specifications at any time without notice In no eve...

Страница 4: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in...

Страница 5: ...ngle Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components Chapter 4 Motherboard Information This chapter lists the h...

Страница 6: ...e of this pin If you outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not b...

Страница 7: ...and Heat sink 33 2 1 3 Installing the Memory 36 2 1 4 Installing Expansion Cards 37 2 1 5 Installing the Mezzanine Card 39 2 1 6 Installing Hard Drives 40 2 2 Rack Mounting 43 2 2 1 Installing the Ser...

Страница 8: ...l Drawing 77 4 4 Board Parts Jumpers and Connectors 78 4 5 Installing the Memory 89 4 6 Installing Add In Cards 93 4 7 Installing the Power Supply 94 Chapter 5 BIOS Setup 95 5 1 About the BIOS 95 5 2...

Страница 9: ...owers your company in today s demanding IT environment but also offers a smooth path for future application usage TYAN also offers the FT77C B7079 in a version that can support up to ten 3 5 or 2 5 ho...

Страница 10: ...40V AC Output Watts 3 200 Watts Processor Supported CPU Series Intel Xeon Processor E5 2600 v3 series Socket Type Q ty LGA2011 2 Thermal Design Power TDP wattage Max up to 160W System Bus Up to 9 6 8...

Страница 11: ...2400 AST2400 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2400 iKVM Feature 24 bit high quality video c...

Страница 12: ...Type Q ty LGA2011 2 Thermal Design Power TDP wattage Max up to 160W System Bus Up to 9 6 8 0 6 4 GT s with Intel QuickPath Interconnect QPI support Chipset Switch IC 4 PLX PEX8747 PCH Intel C612 Memor...

Страница 13: ...tform flash USB 2 0 virtual hub AST2400 iKVM Feature 24 bit high quality video compression 10 100 Mb s MAC interface BIOS Brand ROM size 16MB Feature SMBIOS 2 7 PnP Wake on LAN ACPI 3 0 PXE boot Opera...

Страница 14: ...6 4 GT s with Intel QuickPath Interconnect QPI support Chipset Switch IC 4 PLX PEX8747 PCH Intel C612 Memory Supported DIMM Qty 12 12 DIMM slots DIMM Type Speed RDIMM DDR4 2133 1866 1600 LRDIMM DDR4...

Страница 15: ...BIOS Brand ROM size 16MB Feature SMBIOS 2 7 PnP Wake on LAN ACPI 3 0 PXE boot Operating System OS supported list Please refer to our Intel OS supported list Regulation FCC DoC Class A CE DoC Yes Oper...

Страница 16: ...ch IC 4 PLX PEX8747 PCH Intel C612 Memory Supported DIMM Qty 12 12 DIMM slots DIMM Type Speed RDIMM DDR4 2133 1866 1600 LRDIMM DDR4 2133 1600 LRDIMM 3DS DDR4 2133 1600 Capacity Up to 768GB RDIMM 1 536...

Страница 17: ...I 3 0 PXE boot Operating System OS supported list Please refer to our Intel OS supported list Regulation FCC DoC Class A CE DoC Yes Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operati...

Страница 18: ...DIMM Qty 12 12 DIMM slots DIMM Type Speed RDIMM DDR4 2133 1866 1600 LRDIMM DDR4 2133 1600 LRDIMM 3DS DDR4 2133 1600 Capacity Up to 768GB RDIMM 1 536GB LRDIMM 3 072GB LRDIMM 3DS Intel DDR4 Memory POR...

Страница 19: ...efer to our Intel OS supported list Regulation FCC DoC Class A CE DoC Yes Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90...

Страница 20: ...DDR4 2133 1600 LRDIMM 3DS DDR4 2133 1600 Capacity Up to 768GB RDIMM 1 536GB LRDIMM 3 072GB LRDIMM 3DS Intel DDR4 Memory POR Memory channel 4 Channels per CPU Memory voltage 1 2V Expansion Slots PCI E...

Страница 21: ...100 Mb s MAC interface BIOS Brand ROM size 16MB Feature SMBIOS 2 7 PnP Wake on LAN ACPI 3 0 PXE boot Operating System OS supported list Please refer to our Intel OS supported list Regulation FCC DoC C...

Страница 22: ...1 M1809F77A FB fan board pre installed 1 M2210 L8 1F riser card pre installed 1 M7059F77 D PBP Power Backplane pre installed 1 M7059F77 D PDB Power Distribution Board pre installed 1 M1262F77C BP6 10...

Страница 23: ...23 http www tyan com 1 5 About the Product The following views show you the product 1 5 1 System Front View...

Страница 24: ...t linked HDD LED ON GREEN HDD accessed OFF OFF NO HDD access ID LED ON BLUE system identified OFF OFF system no identified BMC LED ON AMBER Fan fail Over temperature Over voltage PSU fail Blinking AMB...

Страница 25: ...www tyan com 1 5 2 System Rear View 1 Power Supply Cage 2 PCIE x 8 Slot for Mezzanine Card Optional 3 ID LED button 4 VGA USB Port via a dongle cable 5 LAN2 shared with IPMI 6 LAN1 7 ID LED 8 Expansio...

Страница 26: ...mber Solid Amber Active Solid Amber Solid Amber 10Gbps LAN Port LAN Indication 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Link Activity Right LED Speed No Link OFF OFF 10 Mbps Link Solid G...

Страница 27: ...P OVP Fan Fail OTP UVP OFF AMBER Power supply warning events where the power supply continues to operate high temp inlet temperature 60 deg PMBus reading or hot spot temperature 95deg PMBus reading hi...

Страница 28: ...nternal View 1 M1713F77C FPB Front Panel Board 2 Ten 2 5 3 5 HDD Trays with M1262F77C BP6 10 Back Plane Board 3 Six system Fans 4 M7059F77 D PDB Power Distribution Board 5 Power Supply Cage 6 M7059F77...

Страница 29: ...ools can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A ground...

Страница 30: ...metal chassis of the unit case or the bare metal body of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre install...

Страница 31: ...y modules and Add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove FT77C B7079 chassis cover 1 Remove two screws on the back side as show in the small diagram 2 Loosen the...

Страница 32: ...2 http www tyan com 3 Unscrew the top cover and release the latches to remove the top cover from the chassis 4 Here is the overview after the chassis cover was removed 5 Unscrew to remove the air duct...

Страница 33: ...w tyan com 2 1 2 Installing the CPU and Heat sink Follow the steps below on installing CPUs and CPU heat sinks 1 Locate the CPU socket 2 Press the lever and unlock the CPU socket 3 Lift the CPU socket...

Страница 34: ...34 http www tyan com 4 Take out the protection cover and place the CPU to the CPU socket 5 Close the socket cover 6 Close the socket levers...

Страница 35: ...35 http www tyan com 7 Close the socket levers...

Страница 36: ...memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly the memory slot locking levers lock auto...

Страница 37: ...nit card Follow these instructions to install expansion cards 1 Locate the expansion slot on the motherboard unscrew the bracket from the slot you want to use and take out the bracket from the slot 2...

Страница 38: ...tyan com 4 Connect the cables between the expansion card and the power distribution board the connectors you use should match with the slot you add the card with 5 Here is the end of the add on card i...

Страница 39: ...hese instructions to install the Mezzanine Card 1 Locate the PCI E Gen3 x8 slot reserved for the Mezzanine card 2 Push the latches inwards to remove the PCI dummy bracket 3 Prepare a Mezzanine card M7...

Страница 40: ...The FT77C B7079 supports 10 2 5 and 3 5 Hard Drives Follow these instructions to install a hard drive 2 5 Hard Disk Drive 1 Pull the HDD tray out from the chassis 2 Adjusting the 4 HDD lock to the 2...

Страница 41: ...41 http www tyan com 4 Stuck the HDD Module to the HDD tray 5 Reinsert the HDD into the HDD tray...

Страница 42: ...42 http www tyan com 3 5 Hard Disk Drive 1 Adjusting the 4 HDD lock to the 3 5 location 2 Place the 3 5 HDD into the HDD tray 3 Reinsert the HDD into the HDD tray...

Страница 43: ...Server in a Rack Follow these instructions to mount the FT77C B7079 into an industry standard 19 rack Note Before mounting FT77C B7079 in a rack ensure that all internal components have been installe...

Страница 44: ...Screw the mounting ear to each side of FT77 as shown using 3 screws from the supplied screws kit 2 Push the latch key and draw out the inner rails from sliding rails 3 Secure inner rails to both side...

Страница 45: ...www tyan com 2 2 3 Installing the Outer Rails to the Rack 1 The nut was needed and prepared by the customer 2 Secure the outer rail to the rack Using the rail and 4 M5 x 10 screws with washer for eac...

Страница 46: ...ng the Server 1 Draw out the middle rail till the latch position 2 Lift the chassis and then insert the inner slide rails into the middle rails 3 Push the chassis in and pull the latch key A Then push...

Страница 47: ...47 http www tyan com 4 Secure the mounting ears of chassis to the rack with 2 M5 x 13 screws...

Страница 48: ...the S7079 Motherboard M1713F77C FPB Front Panel Board M1809F77A FB Fan Board M2210 L8 1F Riser Card M7059F77 FDR Mezzanine Card M1262F77C BP6 10 HDD Backplane Board M7059F77 D PBP Power Backplane Boar...

Страница 49: ...to remove the cover of FT77C B7079 3 4 Replacing the Power Supply To replace the power supply follow these instructions 1 Press the tab as shown in the diagram and pull out the power 2 Free the power...

Страница 50: ...HDD backplane Follow these instructions to replace the M1262F77C BP6 10 HDD Backplane Board 1 Remove the 4 screws secure the chassis on the left side 2 Removing the 4 screws on the other side 3 Disco...

Страница 51: ...51 http www tyan com 4 Remove the 13 screws secure the HDD cage 5 Lift up the HDD cage from the chassis...

Страница 52: ...3 SATA Connector connect MB 2 SATA Mini SAS Connector connect MB 2 1 4pin power connector JTAG connector SGPIO connector HDD LED connector LEDs 10 HDD active LEDS 10 HDD fault LEDS Board size 377 100M...

Страница 53: ...P1 P2 NC NC P3 P4 GND GND P5 P6 NC VCC5_PRE P7 P8 VCC5_1 VCC5_2 P9 P10 HDD_PRS_L SAS_LED P11 P12 GND VCC12_PRE P13 P14 VCC12_1 VCC12_2 P15 S1 GND SAS_TX S2 S3 SAS_TX GND S4 S5 SAS_RX SAS_RX S6 S7 GND...

Страница 54: ...ions to replace the M7059F77 D PDB Power Distribution Board 1 Unscrew the M7059F77 D PDB Power Distribution Board 2 Remove the power distribution board for replacement 3 Follow the steps described ear...

Страница 55: ...w tyan com 3 6 1 Power Distribution Board Features Form Factor W66 93 x L394 mm 8 layer PCB Connectors Input 1 24S 6P Connector Output 1 2x4 pin Power Connector for Fan Board 16 2x4 pin Power Connecto...

Страница 56: ...P51 58 P61 68 GND VCC12 C1 C6 A1 A6 GND VCC12 D1 D6 B1 B6 GND J2 2 4 Pin ATX Power Connector for FAN Board the max current is 30A Signal Pin Pin Signal GND 1 5 12V GND 2 6 12V GND 3 7 12V GND 4 8 12V...

Страница 57: ...place the power backplane Board Follow these instructions to replace the M7059F77 D PBP Power Backplane Board 1 Make sure to take out three power supply units 2 Disconnect the PBP Power cable 3 Remove...

Страница 58: ...w tyan com 4 Remove the M7059F77 D PBP bracket 5 Unscrew the M7059F77 D PBP from the bracket and replace with a new one Follow the steps described earlier in reverse order to reinstall the power backp...

Страница 59: ...kplane Features Form Factor W80 x L145 mm 8 layer PCB Connectors 3 DPS 1200TB B 80 plus Platinum power connector 1 FCI 24S 6P R A power connector to S S7059GM2NR 1 FCI 24S 6P power connector to M7059F...

Страница 60: ...PB61 PB62 PC61 PC62 PD61 PD62 A1 A2 A3 A4 A5 A6 B1 B2 B3 B4 B5 B6 GND J5 FCI_PWR_CONN_S24P6_RA to PDB Signal Pin Pin Signal VCC12 P11 P18 P21 P28 P31 P38 P41 P48 P51 P58 P61 P68 GND PS1 PWROK C1 A1 1...

Страница 61: ...ND 6 45 GND GND 7 44 GND GND 8 43 GND GND 9 42 GND VCC12 10 41 VCC12 VCC12 11 40 VCC12 VCC12 12 39 VCC12 VCC12 13 38 VCC12 VCC12 14 37 VCC12 VCC12 15 36 VCC12 VCC12 16 35 VCC12 VCC12 17 34 VCC12 VCC12...

Страница 62: ...an com 3 8 Replacing the Riser Card Follow these instructions to replace the M2210 L8 1F Riser Card 1 Unscrew the power supply cage 2 Unscrew the riser card bracket from the chassis 3 Lift out the pow...

Страница 63: ...63 http www tyan com 4 Unscrew the riser card bracket from the chassis 4 Take out the riser card bracket 5 Unscrew to replace with a new riser card...

Страница 64: ...64 http www tyan com 3 8 1 Riser card Feature Form Factor W31 85 x L94 mm 4 layer PCB Specification 1 PCI E Gen3 x8 Slot for non standard add on card...

Страница 65: ...65 http www tyan com 3 9 Replacing the System Fan Board 1 Lift the fan which you need to replace up 2 Remove the 4 screws from the fan cage...

Страница 66: ...om 3 Lift the system fan cage from the chassis 4 Disconnect all the cables from the M1809F77A FB fan board 5 Renew the board and tighten the screw place it back to the chassis following the above proc...

Страница 67: ...com 3 9 1 M1801F77 Fan Board Features Form Factor W81 4 x L312 28 mm 4 layer PCB Specifications 4 1x4P ATX Power Connector for Fan 6 2x2 pin Power Connector 1 2x10 pin System Fan Connector for Motherb...

Страница 68: ...t1 1 2 Tachometer Input6 Tachometer Input2 3 4 Tachometer Input7 Tachometer Input3 5 6 Tachometer Input8 Tachometer Input4 7 8 Tachometer Input9 Tachometer Input5 9 10 Tachometer Input10 GND 11 12 KEY...

Страница 69: ...hese instructions to replace the M1713F77C FPB Front Panel Board 1 Unscrew and disconnect both cables from the front panel board 2 Prepare a new one to replace Follow the procedure described earlier i...

Страница 70: ...Features Integrated I O 10 2 USB3 0 Header connect to MB 15 2 Header connect to MB 2 USB3 0 connector LEDs 1 GREEN BLUE LED for LAN1 and ID 1 GREEN GREEN LED for LAN2 and HDD 1 GREEN AMBER LED for LA...

Страница 71: ...USB3_TX_P1 FP_USB3_TX_N1 15 16 GND FP_USB3_RX_P1 17 18 FP_USB3_RX_N1 VCC_USB 19 20 key J3 15 2 Header Definition Pin Pin Definition PW_LED 1 2 VCC key 3 4 ID_LED PW_LED 5 6 ID_LED HDD_LED 7 8 SYS_FAUL...

Страница 72: ...ing the Motherboard After removing all of the aforementioned cables follow these instructions to remove the motherboard from the chassis 1 Unscrew the power distribution board bracket 2 Take out the p...

Страница 73: ...73 http www tyan com 3 Disconnect all cables 4 Unscrew the motherboard to lift it out...

Страница 74: ...fest conditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the moth...

Страница 75: ...http www tyan com 4 1 Board Image S7079 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pictu...

Страница 76: ...76 http www tyan com 4 2 Block Diagram S7079 Block Diagram...

Страница 77: ...77 http www tyan com 4 3 Mainboard Mechanical Drawing...

Страница 78: ...ion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populatio...

Страница 79: ...in 1 Mini SAS Connector SATA0 3 J32 4 in 1 Mini SAS Connector SSATA0 3 J56 J57 Serial ATA Connector SATA4 SATA5 J46 ID_LED Button Header 3PHD_5 ME Recovery Mode Jumper 3PHD_2 BIOS Advanced mode Jumpe...

Страница 80: ...000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 000000000...

Страница 81: ...4 Signal GND 12V Tachometer Fan PWM Speed Control J60 Front Panel Connector Signal Pin Pin Signal PWRLED 1 2 FP_PWER 3 3V KEY 3 4 IDLED PWRLED 5 6 GND HDDLED 7 8 FAULT_LED 1 HDDLED 9 10 FAULT_LED 2 P...

Страница 82: ...ignal Pin Pin Signal VCC 1 2 VCC USBD 3 4 USBD USBD 5 6 USBD GND 7 8 GND KEY 9 10 NC J58 J59 Vertical Type A USB Connectors Pin 1 2 3 4 Signal VCC USB DATA2 USB DATA2 GND IPMB1 IPMB Connector Signal P...

Страница 83: ...tp www tyan com Caution The jumpers are only using for engineering debug We don t suggest customers change the jumpers position which may cause unable to boot device 3PHD_3 J38 3PHD_1 3PHD_4 3PHD_2 3P...

Страница 84: ...ADDR_MB 15 16 PCH_TPM_PP_EN J38 Chassis Intrusion Header Open Pin 1 2 Signal INTRUSION GND Short Default Open Use this header to trigger the system chassis intrusion alarm Short Use this header to dis...

Страница 85: ...Mode Default Pin 2 3 Closed BIOS CORE Tree Execution 3PHD_3 Flash Security Override Jumper Pin Signal Pin Signal 1 NC 2 MFG_MODE_N 3 GND Pin 1 2 Closed Normal Mode Default Pin 2 3 Closed Security Ove...

Страница 86: ...86 http www tyan com J56 J57 IDLED_BTN PWR_BTN RST_BTN J46...

Страница 87: ...Serial ATA cable 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND LED1 IDLED_BTN ID LED and Button Pin Signal P3V3_AUX ID_SW_L State Color Description On Blue System identified Off Off System not identified NOTE T...

Страница 88: ...ad of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Страница 89: ...tel Xeon E5 2600 V3 series Haswell processor is a four memory channels per CPU design with a total of 8 DDR4 channels This platform supports Registered DDR4 up to 768GB LR DIMM Load Reduced DIMM DDR4...

Страница 90: ...IMM_C0 CPU0_DIMM_C1 CPU0_DIMM_C2 CPU0_DIMM_D0 CPU0_DIMM_D1 CPU0_DIMM_D2 NOTE 1 indicates a populated DIMM slot 2 Install memory in sets of fours for maximum performance This ensures that all four memo...

Страница 91: ...8 10 12 14 16 18 20 22 24 CPU0_DIMM_A0 CPU0_DIMM_A1 CPU0_DIMM_A2 CPU0_DIMM_B0 CPU0_DIMM_B1 CPU0_DIMM_B2 CPU0_DIMM_C0 CPU0_DIMM_C1 CPU0_DIMM_C2 CPU0_DIMM_D0 CPU0_DIMM_D1 CPU0_DIMM_D2 CPU1_DIMM_A0 CPU1...

Страница 92: ...m memory bandwidth 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM 4 Dual rank DIMMs are recommended over single rank DIMMs Intel Xeon...

Страница 93: ...Do not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card TIP...

Страница 94: ...079 motherboard The S7079 supports EPS 12V power supply PWR1 4 Pin Power Connector Signal Pin Pin Signal 12V 1 2 GND GND 3 4 5V PWR2 4 Pin Power Connector Signal Pin Pin Signal 12V 1 2 GND GND 3 4 5V...

Страница 95: ...ion describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are then stored in a dedicated battery backed memory called NVRAM that retains the info...

Страница 96: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 5 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Страница 97: ...e for options that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Memory Information This displays the total memory size System Date Adjust...

Страница 98: ...gs System ACPI Parameters Hardware Health Configuration Hardware health Configuration Parameters Onboard Device Configuration Onboard Device Configuration PCIe Slot Configuration Onboard PCIe Slot Con...

Страница 99: ...ettings PCI PCI X and PCI Express Settings Network stack Configuration Network stack Settings CSM Configuration CSM Configuration Enable Disable Option ROM execution setting etc Trusted Computing opti...

Страница 100: ...Enable ACPI Auto Configuration Enable or disable BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enables or disables System ability to Hibernate OS S4 Sleep State This option may not...

Страница 101: ...elp Disabled Enabled NOTE Auto Fan Control must be set to Enable PWM Minimal Duty Cycle menu will appear PWM Minimal Duty Cycle Duty Cycle control range 30 Duty Cycle 45 Duty Cycle 60 Duty Cycle BMC A...

Страница 102: ...102 5 3 2 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be m...

Страница 103: ...http www tyan com 103...

Страница 104: ...Option ROM for LAN Devices Enabled with iSCSI Enabled with PXE Disabled Load Onboard LAN Port 2 Option R Enable or disable Load Option ROM for LAN Devices Enabled with iSCSI Enabled with PXE Disabled...

Страница 105: ...http www tyan com 105 Wait for F1 if error Wait for F1 stop when BIOS has error appeared Enabled Disabled...

Страница 106: ...PCIe Slot2 3 OPROM Enabled Disabled PCIe Slot OPTROM Configuration Enabled Disabled PCIe Slot4 OPROM Enabled Disabled PCIe Slot OPTROM Configuration Enabled Disabled PCIe Slot5 6 OPROM Enabled Disabl...

Страница 107: ...Link Speed Enabled Disabled PCIe Slot OPTROM Configuration Auto Gen 1 2 5GT s Gen 2 5GT s Gen 3 8GT s PCIe Slot5 6 Link Speed Enabled Disabled PCIe Slot OPTROM Configuration Auto Gen 1 2 5GT s Gen 2...

Страница 108: ...om 108 5 3 5 Watchdog Timer Configuration Watch Dog Mode Watch Dog Mode Help Disabled POST OS PowerON NOTE Watch Dog Timer will appear when Watch Dog Mode is not set to Disabled Watch Dog Timer Watch...

Страница 109: ...http www tyan com 109 5 3 6 ASPEED Super IO Configuration Super IO Chip Read only...

Страница 110: ...r disable Serial Port COM Enabled Disabled Device Settings Read only Change SettingsGSIO600 Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IR...

Страница 111: ...tting Wake system from S5 Enable or disable System wake on alarm event Select Fixed time system will wake on the hr min sec specified Select Dynamic Time System will wake on the current time increase...

Страница 112: ...ole Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the host computer which the user is using will exchange data Both computers...

Страница 113: ...l port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with the...

Страница 114: ...e Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent This is to cap...

Страница 115: ...http www tyan com 115 5 3 8 2 Legacy OS Redirection Settings Legacy OS Redirection Resolution Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages COM1 COM2...

Страница 116: ...for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Settings page for more Help with Terminal Type Emulation VT UTF8 VT100 VT100 ANSI Bits per Sec...

Страница 117: ...www tyan com 117 buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS Data Bits Parity Stop Bits Read...

Страница 118: ...isables 64bit capable Devices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI decoding Enable Disabled SR IOV Support If system has SR IOV capable PCIe Devices this option E...

Страница 119: ...tyan com 119 5 3 9 1 PCI Express settings Maximum Payload Set maximum payload of PCI express device or allow system BIOS to select the value Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes 40...

Страница 120: ...ed by hardware and set to enabled the Downstream Port disables its traditional Devices number field being 0 enforcement when turning a Type1 Configuration request into a Type0 configuration request pe...

Страница 121: ...d legacy PXE OpROM Do not launch UEFI only legacy legacy first UEFI first Storage Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI only legacy legacy first UEFI first Video Contr...

Страница 122: ...chipset is on the Trusted Computing submenu will not appear Security Device Support Enable or disable BIOS support for security device O S will not show Security device O S will not show Security Dev...

Страница 123: ...cations Enabled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled EHCI Hand off This i...

Страница 124: ...e time out value for Control Bulk and Interrupt transfers 20 sec 10 sec 5 sec 1 sec Device reset time out USB mass storage device Start Unit command time out 20 sec 10 sec 30 sec 40 sec Device power u...

Страница 125: ...Configuration Advanced power management Parameters Common RefCode Configuration Common RefCode Configuration QPI Configuration QPI Configuration Memory Configuration Memory Configuration I O Configur...

Страница 126: ...chnology When disabled only one thread Enabled Disabled Execute Disable Bit XD can prevent certain classes of malicious buffer overflow attacks when combined with a supporting OS Windows Server 2003 S...

Страница 127: ...http www tyan com 127 5 4 1 1 CPU Socket0 1 Configuration...

Страница 128: ...http www tyan com 128 5 4 2 Advanced Power Management Configuration Power Technology Enable the power management features Custom Disabled Energy Efficient...

Страница 129: ...129 5 4 2 1 CPU P State Control EIST P States When enabled OS sets CPU frequency according load when disabled CPU frequency is set at max non turbo Enabled Disable Turbo Mode Enable Disable Turbo Mod...

Страница 130: ...te Control Package C State Limit C0 C1 state C2 state C6 non Retention state C6 Retention State CPU C3 Report Enable Disable CPU C3 ACPI C2 report to OS Enable Disable CPU C6 Report Enable Disable CPU...

Страница 131: ...com 131 5 4 3 Common RefCode Configuraion MMIOH Base Select MMIOH Base 56T 48T 24T MMIO High Size Select MMIO High Size 256G 128G 512G 1024G NUMA Enable or Disable Non uniform Memory Access NUMA Enab...

Страница 132: ...as either the Fast Mode or the Slow Mode Fast Slow Link Frequency Select Select the QPI Link Frequency Auto 6 4GT s 9 6GT s 8 0GT s Auto Limited Link L0p Enable Link L0p Enable Disable Enable Auto def...

Страница 133: ...http www tyan com 133 5 4 4 1 QPI Status Submenu Read only...

Страница 134: ...e Stretch Goals Memory Frequency Maximum Memory Frequency Selections in Mhz Do not select Reserved Auto 1333 1400 1600 1800 1867 2000 2133 2200 2400 2600 2667 Reserved Reserved Reserved Reserved ECC S...

Страница 135: ...http www tyan com 135 5 4 5 1 Memory Topology Configuration Read only...

Страница 136: ...http www tyan com 136 5 4 5 2 Memory Thermal Configuration Set Throttling Mode Configure Thermal throttling mode Select OLTT or CLTT mode Disabled OLTT CLTT...

Страница 137: ...Channel Interleaving Select Channel Interleaving setting Auto 1 way Interleave 2 way Interleave 3 way Interleave 4 way Interleave Rank Interleaving Select rank Interleaving setting Auto 1 way Interle...

Страница 138: ...Mirroring is not supported Incase if enabled sparing will be selected Disabled Mirror Lockstep Mode Lockstep x4 DIMMs Enable Disable Lockstep for x4 DIMMs Auto Disabled Enabled Memory Rank Sparing En...

Страница 139: ...http www tyan com 139 5 4 6 I O Configuration Submenu Read only...

Страница 140: ...http www tyan com 140 5 4 6 1 IOAT Configuration Submenu Enable IOAT Control to enable disable IOAT devices Disable Enabled...

Страница 141: ...l VT for Directed I O Configuration Submenu Intel VT for directed I O VT d Enable Disable Intel I O Virtualization Technology for directed I O VT d by reporting the I O device assignment to VMM throug...

Страница 142: ...http www tyan com 142 5 4 7 PCH Configuration Read Only...

Страница 143: ...http www tyan com 143 5 4 7 1 PCH Device Configuration PCH state after G3 Select S0 S5 for ACPI state after a G3 S0 S5 Last State...

Страница 144: ...http www tyan com 144 5 4 7 2 PCH sSATA Configuration...

Страница 145: ...ort Aggressive Link Power Mana Enable or Disable Aggressive Link Power Mana Disabled Enabled sSATA Port 0 1 2 3 Port 0 1 2 3 Disabled Enabled Hot Plug Enable Disable SATA Ports Hot Plug Support Disabl...

Страница 146: ...http www tyan com 146 5 4 7 3 PCH SATA Configuration...

Страница 147: ...t is connected to Solid State Drive or Hard Disk Drive IDE AHCI RAID Support Aggressive Li Enable or Disable Aggressive Li Disabled Enabled SATA Port 0 1 2 3 4 5 Port 0 1 2 3 4 5 Disabled Enabled Hot...

Страница 148: ...ce Type Indentify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Disk Drive Solid State Drive 5 4 7 4 USB Configuration xHCI Mode Mode of operation of xHCI controller Auto Sma...

Страница 149: ...http www tyan com 149 5 4 8 Miscellaneous Configuration Active Video Select active video type Onboard Device Offboard Device...

Страница 150: ...http www tyan com 150 5 5 Server Management...

Страница 151: ...t Disabled Enabled Erase SEL Choose options for erasing SEL No Yes on next reset No on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Log EFI Stat...

Страница 152: ...ration Configuration Address Source Select the configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase...

Страница 153: ...http www tyan com 153 5 6 Security Password Description Read only Administrator Password Install or change the password User Password Install or change the password...

Страница 154: ...http www tyan com 154 5 6 1 Security Flash Update Read Only...

Страница 155: ...ate Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enable or disable Endless Boot Disabled Enabled Boot Option 1 Boot Option 2 Se...

Страница 156: ...http www tyan com 156 5 7 1 Delete Boot Option Configuration Delete Boot Option 1 Sets the system boot order Device Name Select one to Delete...

Страница 157: ...tem setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Options Read only Sav...

Страница 158: ...158 Restore Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all t...

Страница 159: ...6 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Страница 160: ...on 0x30 0x4F PEI execution after memory detection 0x50 0x5F PEI errors 0x60 0x8F DXE execution up to BDS 0x90 0xCF BDS execution 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors...

Страница 161: ...icrocode loading 0x07 AP initialization after microcode loading 0x08 North Bridge initialization after microcode loading 0x09 South Bridge initialization after microcode loading 0x0A OEM initializatio...

Страница 162: ...mory North Bridge initialization is started 0x16 Pre Memory North Bridge initialization North Bridge module specific 0x17 Pre memory North Bridge initialization North Bridge module specific 0x18 Pre M...

Страница 163: ...Boot Strap Processor BSP selection 0x36 CPU post memory initialization System Management Mode SMM initialization 0x37 Post Memory North Bridge initialization is started 0x38 Post Memory North Bridge i...

Страница 164: ...or speed 0x57 CPU mismatch 0x58 CPU self test failed or possible CPU cache error 0x59 CPU microcode is not found or microcode update is failed 0x5A Internal CPU error 0x5B Reset PPI is not available...

Страница 165: ...s codes Recovery Error Codes 0xF8 Recovery PPI is not available 0xF9 Recovery capsule is not found 0xFA Invalid recovery capsule 0xFB 0xFF Reserved for future AMI error codes PEI Beep Codes of Beeps D...

Страница 166: ...C North Bridge DXE initialization North Bridge module specific 0x6D North Bridge DXE initialization North Bridge module specific 0x6E North Bridge DXE initialization North Bridge module specific 0x6F...

Страница 167: ...94 PCI Bus Enumeration 0x95 PCI BUS Request Resources 0x96 PCI Bus Assign Resources 0x97 Console output devices connect 0x98 Console Input devices connect 0x99 Super IO initialization 0x9A USB initial...

Страница 168: ...ug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization codes DXE Error Codes 0xD0 CPU initialization error...

Страница 169: ...met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is entering S4 sleep...

Страница 170: ...planation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the f...

Страница 171: ...http www tyan com 171 BIOS Temp Sensor Name Explanation...

Страница 172: ...http www tyan com 172...

Страница 173: ...of CPU0 DIMM B1 Slot CPU0_DIMM_B2 Temperature of CPU0 DIMM B2 Slot CPU0_DIMM_C0 Temperature of CPU0 DIMM C0 Slot CPU0_DIMM_C1 Temperature of CPU0 DIMM C1 Slot CPU0_DIMM_C2 Temperature of CPU0 DIMM C2...

Страница 174: ...http www tyan com 174 SYS_FAN_2 Fan speed of SYS_FAN_2 SYS_FAN_3 Fan speed of SYS_FAN_3 SYS_FAN_4 Fan speed of SYS_FAN_4 SYS_FAN_5 Fan speed of SYS_FAN_5 SYS_FAN_6 Fan speed of SYS_FAN_6...

Страница 175: ...rd to M7059F77 PDB board Fan board Connect to PDB board J7 J2 J9 J10 J11 3 FP Ctrl USB Cable M1008 FP board to S7079 M1008 FP board Connect to S7079 M B J3 FP Cable J60 J1 USB Cable J34 4 SATA PWR Min...

Страница 176: ...tyan com 176 5 2x3P 2x4P GPU PWR Cable M7059F77 PDB to GPU Card PDB Connect to GPU Card J17 or J18 GPU1 J15 or J16 GPU2 J13 or J14 GPU3 J11 or J12 GPU4 J9 or J10 GPU5 J7 or J8 GPU6 J5 or J6 GPU7 J3 or...

Страница 177: ...00281 A C Power Cord L 1830mm EU type CCBL 146I 422786600004 2x4 pin to 2x 4 pin CCBL 1086 422797000006 For Nvidia K80 cable CCBL 146H 422786600003 2x4 pin to 2x 3 pin FRU CS 0220 422T42300011 MINI SA...

Страница 178: ...z card M7059F77A QDR 2 FRU RC 0020 5411T4760015 PCBA w associate tray M7059F77A FDR 2 FRU RC 0010 5411T4760014 PCBA w associate tray M7059F77A X540 FRU RC 0030 5411T4760022 PCBA w associate tray M7059...

Страница 179: ...power supply and cooling fan The keyboard mouse USB serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other el...

Страница 180: ...h is called as such because it transmits the eight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another P...

Страница 181: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Страница 182: ...CI Peripheral Component Interconnect a 32 or 64 bit local bus data pathway which is faster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which...

Страница 183: ...adjacent data and is often referred to the system s main memory This memory is available to any program running on the computer ROM Read Only Memory a storage chip which contains the BIOS the basic i...

Страница 184: ...out a proper UltraDMA controller your system cannot take advantage of higher data transfer rates of the new UltraDMA UltraATA hard drives USB Universal Serial Bus a versatile port This one port type c...

Страница 185: ...convenient resources just a few keystrokes away users can easily find the latest software and operating system components to keep their systems running as powerful and productive as possible TYAN als...

Страница 186: ...urchase is required before any warranty service can be rendered You may obtain service by calling the manufacturer for a Return Merchandise Authorization RMA number The RMA number should be prominentl...

Отзывы: