TYAN FT70-B7100 Скачать руководство пользователя страница 98

  

 

http://www.tyan.com 

98 

 

 

       

 

Содержание FT70-B7100

Страница 1: ...1 http www tyan com FT70 B7100 Service Engineer s Manual...

Страница 2: ...ing liability or warranties relating to fitness for a particular purpose or merchantability MiTAC retains the right to make changes to produce descriptions and or specifications at any time without no...

Страница 3: ...ese limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre...

Страница 4: ...Do not puncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer D...

Страница 5: ...memory modules hard drivers and other optional parts Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components Chapter 4...

Страница 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Страница 7: ...before you install operate or service TYAN products Symbols on Equipment Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipmen...

Страница 8: ...register Never use the product in a wet location Equipment Chassis Do not block or cover the openings to the system Never push objects of any kind through openings in the equipment Dangerous voltages...

Страница 9: ...idth and depth must allow for proper serviceability and cable management Ensure that there is adequate airflow in the rack Improper installation or restricted airflow can damage the equipment The rack...

Страница 10: ...Equipment Batteries The system battery contains lithium manganese dioxide If the battery pack is not handled properly there is risk of fire and burns Do not disassemble crush puncture short external c...

Страница 11: ...components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring s...

Страница 12: ...nts 28 2 1 1 Removing the Chassis Cover 28 2 1 2 Reinstalling the Chassis Cover 30 2 1 3 Installing the CPU Heatsink 31 2 1 4 Installing the Memory 34 2 1 5 Memory 35 2 1 6 Installing the Expansion Ca...

Страница 13: ...r Pin Definition 69 3 7 Replacing the Power Supply 70 3 8 Replacing the Power Distribution Board 71 3 8 1 Power Distribution Board Features 72 3 8 2 Pin Definitions 73 3 9 Replacing the Power Backplan...

Страница 14: ...bandwidth memory design and lightning fast PCI E bus implementation The FT70 B7100 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage TYAN...

Страница 15: ...Swap SSD HDD rear HDD Backplane Support SATA 6Gb s SAS 12Gb s front SATA 6Gb s rear Supported HDD Interface 26 SATA 6Gb s System Cooling Configuration Redundancy Yes FAN 3 12cm fans Heat Sink 2 Passiv...

Страница 16: ...shared with IPMI Controller Intel I350 AM2 Storage SATA Connector 2 Mini SAS HD 8 ports Controller Intel C621 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RSTe sSATA Connector 2 SATA DOM 1 Mini SAS HD 4 p...

Страница 17: ...Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature Hardware Monitor SMBIOS 3 0 PnP Wake on LAN Boot from USB device PXE via LAN Storage Console Redirection ACPI sleeping states S4 S5 ACPI 6 1 FAN...

Страница 18: ...led 1 M1702T70 USB USB Board pre installed 1 M1809F77A FB Fan Board pre installed 1 M7063F86 PBP Power Backplane pre installed 1 M7063F86 BP6 2 HDD Backplane Board 1 M1271F70 BP12 12 U M1271F70 BP12 1...

Страница 19: ...t Side Switch Indicate Field QTY Specification Power On S W 1 Push type with LED Reset S W 1 Push type ID S W 1 Push type Front Side LED Indicate Field QTY Color Behavior Power LED 1 Green System Powe...

Страница 20: ...n RAID Rebuild Don t care Blinking 4Hz Drive Locate Identifier Don t care Blinking 1Hz 1 5 2 System rear View Rear Side I O Indicate Field QTY Specification LAN port 2 1 Stack for 2 RJ45 1000BASE T US...

Страница 21: ...pply Condition Green LED Amber LED Output ON and OK ON OFF No AC power to all power supplies OFF OFF AC present Only 12VSB on PS off or PS in Smart Redundant state Off line mode 1Hz Blink GREEN OFF AC...

Страница 22: ...p www tyan com 22 1 5 3 Board Image S7100 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pict...

Страница 23: ...http www tyan com 23 1 5 4 Block Diagram...

Страница 24: ...http www tyan com 24 1 5 5 System Top View...

Страница 25: ...63F86 BP6 2 HDD Backplane Board 3 Front Panel Bezel M1701T70 FPB pre installed 8 2 HDD bays Each HDD bay support one 2 5 SATA 6G HDDs SSDs 4 HDD Backplane Board M1271F70 BP12 12 U and M1271F70 BP12 12...

Страница 26: ...er tools can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A he...

Страница 27: ...d touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static su...

Страница 28: ...SSD and Expander Card 2 1 1 Removing the Chassis Cover Follow these instructions to remove the FT70 B7100 chassis cover 1 Remove the two screws on the both sides 2 Press the button to lift the cover u...

Страница 29: ...http www tyan com 29 4 Unscrew to remove the air ducts from the chassis 5 Follow the steps reverse to reinstall the chassis cover...

Страница 30: ...to the chassis and slide the top cover into the place Tighten the thumbscrew and secure the back screw NOTE The thumbscrews should be tightened with a screwdriver after the top chassis cover is closed...

Страница 31: ...e heatsink Then install the carrier assembly on the bottom of the heatsink and make sure the gold arrow is located in the correct direction NOTE A new heatsink comes with pre applied thermal grease On...

Страница 32: ...com 32 3 Take out the protection cap 4 Align the heatsink on the CPU socket by the guide pins and make sure the gold arrow is located in the correct direction Then place the heatsink onto the top of t...

Страница 33: ...ecure the heatsink use a T30 Security Torx to tighten the screws in a sequential order 1 2 3 4 When disassembling the heatsink loosen the screws in reverse order 4 3 2 1 6 Place the CPU air duct back...

Страница 34: ...ing levers in the direction of the arrows as shown in the following illustration Always start at CPU0_DIMM_A0 2 Align the memory module with the slot When inserted properly the memory slot locking lev...

Страница 35: ...http www tyan com 35 2 1 5 Memory...

Страница 36: ...pulated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM Dual CPU install...

Страница 37: ...even expansion slots Follow these instructions to install the SAS card 1 Locate the PCI E Gen 3 x8 slots on the motherboard Unscrew to take out the dummy brackets 2 Insert the SAS card into the PCIE G...

Страница 38: ...http www tyan com 38 3 Connect the Mini SAS HD Cable...

Страница 39: ...or 3 5 SAS SATA SSDs HDDs 12G 6G hard drives and 2 hot swap 2 5 SATA 6G SSDs HDDs Warning Always install the hard disk drive to the chassis after the chassis is secured on the rack Installing Front 3...

Страница 40: ...http www tyan com 40 3 Place a hard drive into the drive tray Use four screws to secure the HDD SSD 4 Reinsert the HDD tray into the chassis 5 Press down the latch to unlock the HDD trays...

Страница 41: ...d Drives Follow these instructions to install a 2 5 HDD SSD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and...

Страница 42: ...http www tyan com 42 3 Place the 2 5 HDD SSD into the HDD tray and align the 2 5 HDD SSD with its guide pins 4 Turn over the HDD tray and secure the HDD SSD to the tray using 4 screws...

Страница 43: ...http www tyan com 43 5 Reinsert the HDD tray into the chassis 6 Press down the latch to unlock the HDD trays...

Страница 44: ...llow these instructions to install a 2 5 HDD SSD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch 2 pull the loc...

Страница 45: ...http www tyan com 45 4 Secure one side HDD screws 5 Secure the other side HDD screws 6 Reinsert the HDD tray into the chassis 7 Push to secure the locking lever until it clicks into place...

Страница 46: ...st two people lift the TYAN FT70 B7100 to and from the rack Rack mounting kit No Item Description Quantity A Sliding rails 2 B Screw packet in rail kit 1 2 2 1 Installing the Server in a Rack NOTE Bef...

Страница 47: ...tab and take out the inner rail from the rail assembly 2 Release the latch according to the arrow s direction and slide the intermediate rail back 3 Install the inner rail onto the chassis 4 Install t...

Страница 48: ...nd that the unit has been fully tested However to make the installation easier we suggest that you remove all HDD trays before you insert the chassis to the rack 1 Fix the outer rail bracket assembly...

Страница 49: ...http www tyan com 49 4 Slide the chassis back into the rack 5 Screw the chassis to the rack using 2 pcs screws 6 The installation is now complete...

Страница 50: ...herboard M1271F70 BP12 12 U M1271F70 BP12 12 L M7063F86 BP6 2 HDD Backplane Board P3280 24I SAS Expander Card M1701T70 FPB Front Panel Board M1702T70 USB USB Board M1809F77A FB Fan Board M7063F86 PBP...

Страница 51: ...ove the chassis cover Follow Section 2 1 1 Removing the Chassis Cover page 28 to remove the cover of the FT70 B7100 3 2 Replacing the System Fans Follow these instructions to replace the fans 1 Take o...

Страница 52: ...http www tyan com 52 3 3 Replacing the Fan Board Follow these instructions to replace the Fan Board 1 Remove all the system fans from the fan cage 2 Remove the four screws 3 Lift the fan chassis up...

Страница 53: ...n com 53 4 Disconnect all the cables from the fan board 4 Unscrew the fan board to replace a new one 5 Assemble the fan cage and system fans back into the chassis following the steps described earlier...

Страница 54: ...ader 1 4 pin Fan Signal Control Header 3 3 2 Fan Board LED Definition FAN Status Green LED Red LED With Fan Speed RPM OK On Off Fan Failed or Without Fan Off On 1 FAN1 Connector J1 7 Big 4 pin Power C...

Страница 55: ...D 1 2 VDD 12V TACH 3 4 PWM PW1 PW2 PW3 Big 4 pin Power Connector Definition Pin Pin Definition VDD 12V 1 2 GND GND 3 4 NC J8 Fan Control Header Definition Pin Pin Definition TACH1 1 2 TACH6 TACH2 3 4...

Страница 56: ...ons to replace the M1271F70 BP12 12 U L HDD Backplane Boards Before replacing the board remove all the hard disk trays M1271F70 BP12 12 U L HDD BP Board 1 Disconnect the all the cables from the backpl...

Страница 57: ...n com 57 4 Take out the HDD BP board 5 Release 16 push pins to lift the mylar 6 Loose sixteen screws to replace with a new HDD BP Board 7 Reinstall the HDD BP Board into the chassis following the step...

Страница 58: ...D BP Board 1 Disconnect the all the cables from the backplane 2 Unscrew the HDD BP bracket and release the backplane from the hook 3 Prepare a new HDD BP Board for replacement and reinstall it into th...

Страница 59: ...ctor W429 8 x L78 4 mm 8 layer PCB Specifications 12 SAS SATA HDD SSD Connector connected to HDD SSD SAS0 11 3 Mini SAS HD Connector connected to MB MINI_SAS0 2 1 12 pin Power Connector connected to M...

Страница 60: ...86 BP6 2 HDD Backplane Board in details Front view Rear view M7063F86 BP6 2 HDD Backplane Board Form Factor 8 layer PCB Integrated I O 1 Big 4 pin Power Connector PW2 2 7 pin SATA Connector 2 HDD Conn...

Страница 61: ...N GND 6 12 VDD_12_RUN J36 30 pin FAN Connector Definition Pin Pin Definition FAN_TACH1 1 2 FAN_TACH6 FAN_TACH2 3 4 FAN_TACH7 FAN_TACH3 5 6 FAN_TACH8 FAN_TACH4 7 8 FAN_TACH9 FAN_TACH5 9 10 FAN_TACH10 G...

Страница 62: ...6 pin FAN Connector Definition Pin Pin Definition VDD_12_FAN1 1 2 GND CON_PWM1 3 4 FAN_TACH1 VDD_12_FAN1 5 6 GND M7063F86 BP6 2 HDD Backplane Board PW2 Big 4 pin Power Connector Signal Pin Pin Signal...

Страница 63: ...w tyan com 63 3 5 Replacing the Front Panel Board Follow these instructions to replace the M1701T70 FP Front Panel Board 1 Unscrew to release the Front Panel Board cover 2 Remove the Front Panel Board...

Страница 64: ...p www tyan com 3 Unscrew the Front Panel Board to replace a new one 4 Disconnect the Front Panel Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the Front Panel...

Страница 65: ...Connectors One 2x15 pin header for front panel connector of motherboard and HDD backplane board LEDs Power On Off LED Color Green after power on ID LED Color Blue Warning IPMI LED Dual Color Amber Wa...

Страница 66: ...failure ID LED On Blue System identified remotely on the server by clicking the Chassis Locate LED key Off Off System not identified J1 FPIO connector Definition Pin Pin Definition PW_LED 1 2 5VSB Ke...

Страница 67: ...67 http www tyan com 3 6 Replacing the USB Board Follow these instructions to replace the M1702T70 USB Board 1 Unscrew to release the USB front cover 2 Remove the USB front cover...

Страница 68: ...68 http www tyan com 3 Unscrew the USB Board 4 Disconnect the USB Board to replace a new one Follow the steps described earlier in reverse to reinstall the USB Board...

Страница 69: ...rboard 2 USB ports 3 6 2 USB Board Connector Pin Definition J2 2x5 pin Connector for FP Connector of Motherboard Pin Definition Description Pin Definition Description 1 VCC_USB USB power 2 VCC_USB USB...

Страница 70: ...installed Power Supply Units Please unplug the power cord before you follow these instructions to replace the power supply units 1 Press the latch to pull the power supply out 2 After replacing a new...

Страница 71: ...Power Distribution Board 1 Disconnect the all cables from the power distribution board 2 Unscrew the power distribution board 3 Push the power supply cage forwards to take out the power distribution...

Страница 72: ...Board Features M7100F48B PDB Power Distribution Board Board Size 82mm x 127 3mm 6 layer PCB Integrated I O 3 8 pin power connector 3 4 pin power connector 2 20 pin power connector 1 24 pin power conn...

Страница 73: ...Connector Definition Pin Pin Definition GND 1 2 GND 12V 3 4 5V PW6 PW7 PW8 8 pin Power Connector Definition Pin Pin Definition GND 1 5 12V GND 2 6 12V GND 3 7 12V GND 4 8 12V PW2 PW3 20 Pin Power Conn...

Страница 74: ...4 PW5 24 pin Power Connector Definition Pin Pin Definition 3 3V 1 13 3 3V 3 3V 2 14 NA GND 3 15 GND 5V 4 16 PS_ON GND 5 17 GND 5V 6 18 GND GND 7 19 GND PW_GD 8 20 NA 5VSB 9 21 5V 12V 10 22 5V 12V 11 2...

Страница 75: ...063F86 PBP Power Backplane Board 1 Unscrew the Power BP Board Tray from the chassis 2 Slide to take out the power backplane board tray 3 Unscrew to replace with a new power backplane board 4 Follow th...

Страница 76: ...m 76 3 10 Disconnecting All Motherboard Cables Before replacing the motherboard or certain components remove cables connected to the motherboard Follow these instructions to remove all cables 1 Discon...

Страница 77: ...erboard After removing all of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the nine screws securing the motherboard to the chassis 2 Care...

Страница 78: ...http www tyan com 78 NOTE...

Страница 79: ...1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard ple...

Страница 80: ...errors 0x60 0x8F DXE execution up to BDS 0x90 0xCF BDS execution 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standa...

Страница 81: ...idge initialization after microcode loading 0x0A OEM initialization after microcode loading 0x0B Cache initialization SEC Phase None PEI Phase SEC Error Codes 0x0C 0x0D Reserved for future AMI SEC err...

Страница 82: ...zation is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initial...

Страница 83: ...ule specific 0x3D Post Memory South Bridge initialization South Bridge module specific 0x3E Post Memory South Bridge initialization South Bridge module specific 0x3F 0x4E OEM post memory initializatio...

Страница 84: ...A S3 Resume Boot Script error 0xEB S3 OS wake error 0xEC 0xEF Reserved for future AMI error codes Recovery Progress Codes 0xF0 Recovery condition triggered by firmware Auto recovery 0xF1 Recovery cond...

Страница 85: ...ific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 CPU DXE initialization CPU module specific 0x68 PCI host bridge initialization 0x69 North Brid...

Страница 86: ...A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PCI Bus initialization is started...

Страница 87: ...rtual Address MAP End 0xB2 Legacy Option ROM initialization 0xB3 System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF...

Страница 88: ...l is not available 8 Platform PCI resource requirements cannot be met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 Sy...

Страница 89: ...http www tyan com 89 NOTE...

Страница 90: ...nt shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the...

Страница 91: ...the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion is...

Страница 92: ...USB BD to S7100 MB USB BD Connect to S7100 MB USB cable J2 USB3_FPIO2 3 Mini SAS HD cable M1271F70 BP1 2 12 BP Connect to P3280 24I Mini SAS HD cable 1 MINI_SAS0 L J22 Mini SAS HD cable 2 MINI_SAS1 L...

Страница 93: ...AN BP Connect to PDB Fan BP PWR cable J7 J9 J10 J11 PW8 6 SAS and SGPIO cable M7063F86 BP6 2 BP Connect to S7100 MB SAS cable 1 J5 SSATA4 SAS cable 2 J6 SSATA5 SGPIO cable J3 SSATA_SGPIO 7 HDD BP PWR...

Страница 94: ...0 MB PDB Board Connect to S7100 MB 2x12P PWR cable PW5 PWCN1 2x4P PWR cable 1 PW7 PWCN2 2x4P PWR cable 2 PW6 PWCN3 PSMI cable J1 SP_PSMI 9 COM port Switch cable Chassis to S7100 MB Chassis Connect to...

Страница 95: ...4800RPM 12 0X120X38 DELTA 4 pin Heatsink FRU TH 0220 343T56600001 PASSIVE HEATSINK Expender Card P3280 24I 5411T5640021 P3280 24I SAS Expander Card Slide Rail Kit FRU AS 9140 452T60200005 Slide Rail K...

Страница 96: ...explanation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the...

Страница 97: ...http www tyan com 97 BIOS Temp Sensor Name Explanation...

Страница 98: ...http www tyan com 98...

Страница 99: ...nel B slot P1_MC0_DIM_CH_C The highest temperature of CPU1 DIMM channel C slot P1_MC1_DIM_CH_D The highest temperature of CPU1 DIMM channel D slot P1_MC1_DIM_CH_E The highest temperature of CPU1 DIMM...

Страница 100: ...http www tyan com 100 SYS_FAN10 Fan speed of SYS_FAN10 SYS_FAN11 Fan speed of SYS_FAN11 SYS_FAN12 Fan speed of SYS_FAN12...

Страница 101: ...expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports...

Страница 102: ...roper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manu...