TYAN B8253T65V10E4HR Скачать руководство пользователя страница 27

27 

http://www.tyan.com

 

Rear I/O: Onboard LAN LED Color Definition 
 

The 

four (4)

 onboard Ethernet ports have green and amber LEDs to indicate LAN 

status. The chart below illustrates the different LED states. 

 

 

1Gbps LAN Port 

 

10/100/1000 Mbps LAN Link/Activity LED Scheme 

 

Left LED 

Right LED 

10 Mbps 

Link 

Green Off 

Active 

Blinking Green 

Off 

100 Mbps 

Link 

Green Green 

Active 

Blinking Green 

Green 

1000 

Mbps(1Gps) 

Link 

Green Amber 

Active 

Blinking Green 

Amber 

No Link 

Off Off 

 

 

10Gbps LAN Port 

 

10/100/1000 Mbps LAN Link/Activity LED Scheme 

 

Left LED 

(Link/Activity) 

Right LED 

(Speed) 

No Link 

 

OFF OFF 

100 Mbps 

Link 

Solid Green 

Solid Green 

Active 

Blinking Green 

Solid Green 

1000 Mbps 

Link 

Solid Green 

Solid Amber 

Active 

Blinking Green 

Solid Amber 

 (10Gbps) 

Link 

Solid Amber 

Solid Amber 

Active 

Solid Amber 

Solid Amber 

 
 
 
 
 

Содержание B8253T65V10E4HR

Страница 1: ...1 http www tyan com TS65 B8253 Service Engineer s Manual ...

Страница 2: ...luding liability or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without notice In no event will MITAC be held liable for any direct or indirect incidental or consequential damage loss of use loss of data or other malady resulting from errors or inaccuracies of informatio...

Страница 3: ...se limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely ...

Страница 4: ...ery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Dispose of used battery according to manufacturer instructions and in accordance with your local regulations VCCI A この装置は クラスA機器です この装置を住宅環境で使用すると電波妨害を引き 起こすことがあります この場合には使用者が適切な対策を講ずるよう要求される ことがあります VCCI A Safety IEC EN 62368 1 This equipment i...

Страница 5: ...s list describes the external components gives an overview of the product from different angles Chapter 2 Setting Up This chapter covers procedures on installing the processors memory modules hard drivers and other optional parts Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components Chapter 4 Diagnostics This chapte...

Страница 6: ...n to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not be in the way of foot traffic Follow all warnings and cautions in this manual and on the unit case Do not push objects in the ventilation slots as they may touch high voltage components and result in shock and damage to the components When replacing parts ensure that you use parts speci...

Страница 7: ...ed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning This symbol indicates the presence of hazardous energy circuits or electric shock hazards Refer all servicing to qualified personnel Warning This symbol indicates the presence of a hot surface or hot component If this surface is contacted the potential for in...

Страница 8: ... register Never use the product in a wet location Equipment Chassis Do not block or cover the openings to the system Never push objects of any kind through openings in the equipment Dangerous voltages might be present Conductive foreign objects can produce a short circuit and cause fire electric shock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Ra...

Страница 9: ...width and depth must allow for proper serviceability and cable management Ensure that there is adequate airflow in the rack Improper installation or restricted airflow can damage the equipment The rack cannot have solid or restricted airflow doors You must use a mesh door on the front and back of the rack or remove the doors to ensure adequate air flow to the system If you install the Model in a r...

Страница 10: ...isk of electrical shock disconnect all power cords before servicing the appliance Equipment Batteries The system battery contains lithium manganese dioxide If the battery pack is not handled properly there is risk of fire and burns Do not disassemble crush puncture short external contacts or dispose of the battery in fire or water Do not expose the battery to temperatures higher than 60 C 140 F Th...

Страница 11: ...es rings or loose jewelry when working before removing covers and touching internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider Exa...

Страница 12: ... 34 2 1 Installing Motherboard Components 35 2 1 1 Removing the Chassis Cover 35 2 1 2 Removing the Riser Bracket and Air Duct 36 2 1 3 Replacing the Chassis Cover 37 2 1 4 Installing the CPU and Heatsink 38 2 1 5 Installing the PCI E Card 42 2 1 6 Installing the Memory 43 2 1 7 Installing Hard Drives 46 2 2 Rack Mounting 53 2 2 1 Installing the Server in a Rack 53 2 2 2 Rack mounting the Server 5...

Страница 13: ...eplacing the Power Distribution Board 73 3 9 1 Power Distribution Board Features 74 3 9 2 Pin Definitions 75 3 10 Replacing the Power Backplane Board 77 3 11 Replacing the Rear HDD Backplane Board 79 3 11 1 HDD Backplane Features 80 3 11 2 HDD LED Definition 81 3 12 Replacing the Power Supply 82 3 13 Replacing the Motherboard 83 Appendix I How to recover UEFI BIOS 85 Appendix II Cable Connection T...

Страница 14: ...14 http www tyan com ...

Страница 15: ...n nowadays IT demand but also offers a smooth path for future application usage TYAN also offers TS65 B8253 in a version that supports up to twelve hot swap 2 5 3 5 SATA HDD SSD with four NVMe SSD option and two hot swap 2 5 SSD HDD The TS65 B8253 uses TYAN s latest chassis featuring a robust structure and a solid mechanical enclosure All of this provides TS65 B8253 the power and flexibility to me...

Страница 16: ...t 2 2 5 Hot Swap SSD HDD rear HDD Backplane Support SAS 12Gb s SATA 6Gb s NVMe Supported HDD Interface 12 SATA 6Gb s with 4 NVMe ports front 2 SATA 6Gb s rear Notification The SAS SATA HDD backplane is connected to onboard SATA connection by default Please contact Tyan technical support if a discrete SAS HBA RAID adapter is required System Cooling Configuration FAN 3 8cm fans Power Supply Type CRP...

Страница 17: ...Gen4 x8 slot Pre install TYAN Riser Card PCI E Gen4 1 M8253T65 R32 3F riser card for 3 FH HL PCI E Gen4 x8 slot right Physical Dimension Abbreviation FH HL Full height Half length 4 4 x 6 6 111 2 x 167 7mm LAN Q ty Port 2 GbE ports 1 GbE dedicated for IPMI Controller Intel I210 PHY Realtek RTL8211E Storage SATA Connector 3 Mini SAS HD 12 ports 2 7 pin White SATA 6G ports w Power conn support SATA ...

Страница 18: ...ail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC 10 100 1000 Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature Hardware Monitor SMBI...

Страница 19: ...me S8253GM4NE 2T Gross Weight 24 24 kg 53 44 lbs Net weight 16 5 kg 36 38 lbs Front Panel Buttons 1 RST 1 PWR w LED 1 UID LEDs 2 LAN 1 UID 1 System Event I O Ports 2 USB 3 1 Gen1 ports External Drive Bay Q ty Type 12 3 5 2 5 Hot Swap SSD HDD front 2 2 5 Hot Swap SSD HDD rear HDD Backplane Support SAS 12Gb s SATA 6Gb s NVMe Supported HDD Interface 12 SATA 6Gb s with 4 NVMe ports front 2 SATA 6Gb s ...

Страница 20: ...LRDIMM LRDIMM 3DS 3200 Capacity Up to 1 024GB RDIMM 4 096GB LRDIMM 3DS Memory channel 8 Channels per CPU Memory voltage 1 2V Expansion Slots PCI E 1 PCI E Gen4 x32 slot 3 PCI E Gen4 x16 slot 1 PCI E Gen4 x8 slot Pre install TYAN Riser Card PCI E Gen4 1 M8253T65 R32 3F riser card for 3 FH HL PCI E Gen4 x8 slot right Physical Dimension Abbreviation FH HL Full height Half length 4 4 x 6 6 111 2 x 167...

Страница 21: ...ystem Monitoring Chipset Aspeed AST2500 Temperature Monitors temperature for CPU memory system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage ove...

Страница 22: ... CB LVD Yes RCM Class A VCCI Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Barebone 1 TS65 B8253 Barebone Manual 1 Quick Installation Guide NOTE 1 The specifications are subject to change without prior notice 2 Please visit our website for the ...

Страница 23: ...d S8253GM4NE 2T on B8253T65V10E4HR 2T SKU S8253GM2NE on B8253T65V10E4HR SKU 4 HDD Backplane M1297T65 BP12E 12 pre installed 5 HDD Backplane M1298T65 BP12E 2 pre installed 6 Front panel board M1718T65 FPB pre installed 7 USB board M1717T65 USB pre installed 8 Power board M7100F48B PDB pre installed 9 Power board M7063F86 PBP pre installed 10 Riser card M8253T65 R32 3F pre installed 11 3 system fans...

Страница 24: ... USB USB Board 1 LAN1 LED 7 ID Button 2 LAN2 LED 8 Power Button with green LED 3 ID LED 9 USB3 1 Port1 4 Warning LED 10 USB3 1 Port2 5 HDD LED N A always OFF 11 3 5 2 5 SSD HDD NVMe bays 6 RESET Button NOTE The Front Panel HDD LED is dedicated for M 2 HDD only The S8253 mainboard does not support M 2 Therefore The Front Panel HDD LED is always OFF ...

Страница 25: ... 1 Red Green Blue System normal All off Memory warning Green blinking PSU warning Blue solid on FAN warning Blue blinking System fault Red solid on HDD LED 1 Green Red HDD present Green solid on HDD activity Green blinking HDD fail Red solid on HDD LED Definitions Drive Status Activity LED Green Status LED Red Drive present no activity Green Solid On Off Drive present with activity Green Blinking ...

Страница 26: ...LAN4 NOTE RJ45 1Gb LAN3 LAN4 is from INTEL I210 chipset RJ45 10Gb LAN2 LAN1 is from INTEL X550 chipset ID LED Definition LED State Color Description ID LED On Blue System identified Off Off System not identified NOTE Press the ID button when the system AC Alternating Current is on then the ID LED will light blue if the system is identified Users from remote sites can also activate the ID LED by en...

Страница 27: ...Green Off Active Blinking Green Off 100 Mbps Link Green Green Active Blinking Green Green 1000 Mbps 1Gps Link Green Amber Active Blinking Green Amber No Link Off Off 10Gbps LAN Port 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Link Activity Right LED Speed No Link OFF OFF 100 Mbps Link Solid Green Solid Green Active Blinking Green Solid Green 1000 Mbps Link Solid Green Solid Amber Active...

Страница 28: ... M1718T65 FPB Front Panel Board pre installed 3 HDD Bays 4 M1297T65 BP12E 12 HDD backplane Board pre installed 5 System fans 6 M7100F48B PDB Power Distribution Board 7 Power Modules 8 M1298T65 BP12E 2 HDD backplane Board pre installed 9 Riser Card Bracket M8253T65 R32 3F pre installed ...

Страница 29: ...29 http www tyan com 1 5 4 Chassis Dimension ...

Страница 30: ...p www tyan com 1 5 5 Board Image S8253GM4NE 2T This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture ...

Страница 31: ...http www tyan com 31 1 5 6 Block Diagram S8253 Block Diagram NOTE Please visit our TYAN web site for more MB details on S8253 ...

Страница 32: ...32 http www tyan com NOTE ...

Страница 33: ... can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static pad A T20 Security Torx screwdriver Most of the electrical and mechanical connections can be disconnected with your hands It is recommended that you do not use pliers to remove...

Страница 34: ... any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static surface until you are ready to reinstall it Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do so Do...

Страница 35: ...nents on to the mainboard including CPUs memory modules and add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove TS65 B8253 chassis cover 1 Loosen two screws on the top cover 2 Push the latches simultaneously and slide the chassis cover backwards 3 Lift the chassis cover up ...

Страница 36: ...36 http www tyan com 2 1 2 Removing the Riser Bracket and Air Duct 1 Use a screwdriver to loosen the thumb screw and then lift up the Riser Card Bracket and the air duct ...

Страница 37: ...s Cover Follow these instructions to replace TS65 B8253 chassis cover 1 Place the chassis cover on top 2 Push the latches simultaneously and slide the chassis cover forwards until it clicks 3 Use a screw driver to fasten the screws on the top cover ...

Страница 38: ...w the steps below to install CPUs and CPU heat sinks 1 Use a T20 Torx screwdriver to loosen the screws securing the force frame in a sequential order 3 2 1 NOTE The force frame will automatically eject after the captive screws are being released 2 By placing your both index fingers on the sides on the metal handle pull to release the rail frame Then lift the rail frame to its fully open position ...

Страница 39: ...install the carrier frame with package into the slot on the rail frame 5 Using your thumbs and forefinger remove the PnP cap by lifting it up vertically Carefully close the rail frame with the installed package Then push both edges of the rail frame firmly until it locks in place ...

Страница 40: ... or touch the package pad to avoid component damage 6 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure the force frame in a sequential order 1 2 3 7 To secure the heatsink use a T20 Security Torx to tighten four screws Tighten four screws in a diagonal sequence to secure the heat sink Repeat the same procedures described earlier to install the second processor ...

Страница 41: ...41 http www tyan com 8 Take out the air duct Remember to install the air duct after the second processor and heatsink are installed ...

Страница 42: ...stall the PCI E card 1 Unscrew to lift up the riser card bracket 2 Unscrew to remove the dummy bracket 3 Insert the PCI E card into the slot and screw it firmly to the riser card bracket 4 Replace the riser card bracket into the chassis and use a screw driver to fasten the thumb screw ...

Страница 43: ...memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly the memory slot locking levers lock automatically onto the indentations at the ends of the module Follow the recommended memory population table to install the other memory modules ...

Страница 44: ...44 http www tyan com DIMM Location ...

Страница 45: ...8 10 12 14 16 P0_UMC0_CH_A0 Not Recommended Not Recommended v P0_UMC1_CH_B0 v P0_UMC3_CH_C0 v v P0_UMC2_CH_D0 v v P0_UMC6_CH_E0 v P0_UMC7_CH_F0 v P0_UMC5_CH_G0 v v P0_UMC4_CH_H0 v v P1_UMC0_CH_A0 v P1_UMC1_CH_B0 v P1_UMC3_CH_C0 v v P1_UMC2_CH_D0 v v P1_UMC6_CH_E0 v P1_UMC7_CH_F0 v P1_UMC5_CH_G0 v v P1_UMC4_CH_H0 v v DIMM Population Chan2 DDR4 Frequency MT s DIMM Type3 DIMM 0 DIMM 1 Rome in legacy ...

Страница 46: ...o 2 5 hot swap HDD SSDs at rear Installing 3 5 Hot Swap Hard Drives Follow these instructions to install a 3 5 HDD drive Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch to pull the locking lever open 2 Slide the drive tray out ...

Страница 47: ...open the locking lever to install a 3 5 hard disk drive into the HDD drive tray and lock the tray lever to secure the drive 4 Reinsert the HDD drive tray into the chassis Push to secure the locking lever until it clicks into place ...

Страница 48: ...ves Follow these instructions to install a 2 5 HDD SSD drive Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch to pull the locking lever open 2 Slide the drive tray out ...

Страница 49: ...49 http www tyan com 3 Place the 2 5 HDD SSD into the drive tray and align the 2 5 HDD SSD with its guide pins 4 Turn over the drive tray and secure the drive to the tray using 4 screws ...

Страница 50: ...50 http www tyan com 5 Reinsert the drive tray into the chassis Push to secure the locking lever until it clicks into place ...

Страница 51: ... HDD drive at rear Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch to pull the locking lever open 2 Pull open the locking lever to install a 2 5 hard disk drive into the drive tray and lock the tray lever to secure the drive ...

Страница 52: ...52 http www tyan com 3 Reinsert the drive tray into the chassis Push to secure the locking lever until it clicks into place ...

Страница 53: ...in a rack ensure that all internal components have been installed and that the unit has been fully tested However to make the installation easier we suggest that you remove all HDD trays before you insert the chassis into the rack Installing the Inner Rails to the Chassis 1 Draw out the inner rail from the rail assembly When the rail comes to a stop push the white tab in the direction as the arrow...

Страница 54: ...4 http www tyan com 3 Repeat steps 2 to 4 to secure the sliding rail to the other side of the server NOTE Use a screwdriver to slightly push the latch open and then push the inner rail forwards to unlock ...

Страница 55: ... the Rack 1 Attach the outer rail to the rack Pull the latch open and align the square stud with the square hole on the rack rail Please note that the square stud must be fully attached inside the square hole and then close the latch to lock Rear Front ...

Страница 56: ...56 http www tyan com ...

Страница 57: ... the chassis into the rails Must be done with at least 2 people Properly place the chassis directly on the rack and install 2 Slide in the chassis half way to the lock position Push the blue tabs simultaneously to slide the chassis all in 3 Use a screw driver to fasten the chassis ears to the front surface of chassis ...

Страница 58: ...nscrew the chassis ears Press the latches to pull out the chassis 2 Pull out the chassis half way to the lock position Push the white locking tabs forwards to slide the chassis all out from the rack Caution Remove the server from the rack carefully Must be done with at least 2 people ...

Страница 59: ...ding the Motherboard M1717T65 FPB Front Panel Board M1718T65 USB Board M1297T65 BP12E 12 HDD Backplane M1298T65 BP12 2 HDD Backplane M7100F48B PDB Power Distribution board M7063F86 PBP Power Backplane Board M8253T65 R32 3F Riser card System fan and Power supply unit etc 3 2 Disassembly Flowchart The following flowchart outlines the disassembly procedure ...

Страница 60: ... Components Follow these instructions to replace motherboard components including the motherboard 3 4 1 Replacing the Riser Card Follow these instructions to replace the M8253T65 R32 3F Riser Card 1 Unscrew to lift up the riser card bracket 2 Unscrew the M8253T65 R32 3F riser card to replace with a new one 3 Follow the steps described earlier in reverse order to reinstall the riser card bracket ...

Страница 61: ... M8253T65 R32 3F Riser Card Form Factor 68 47mmx131mm T 1 6mm Specifications PCI E x16 SLOT x1 PCI E x8 SLOT x2 4P PWR Connector x1 3 4 3 Connector Pin Definition Location Definition J1 PCI E 2 J2 PCI E 3 J3 PCI E 1 J4 PWR1 PCI E X16 SLOT PCI E X8 SLOT PCI E X8 SLOT 4P Power Connector ...

Страница 62: ...ww tyan com 62 3 5 Replacing the Front Panel Board Follow these instructions to replace the M1718T65 FPB Front Panel Board 1 Unscrew to release the Front Panel Board cover 2 Remove the Front Panel Board cover ...

Страница 63: ...www tyan com 63 3 Unscrew the Front Panel Board to replace a new one 4 Disconnect the Front Panel Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the Front Panel Board ...

Страница 64: ...Board Specifications M1718T65 FPB Front Panel Board Form Factor 18mmx40mm T 1 6mm Specifications power button with LED reset button ID button LED LAN1 LED green LAN2 LED green ID LED blue HDD LED green Red FAULT LED Red green Blue Power LED ...

Страница 65: ...http www tyan com 65 3 6 Replacing the USB Board Follow these instructions to replace the M1717T65 USB Front USB Board 1 Unscrew to release the USB front cover 2 Remove the USB front cover ...

Страница 66: ...http www tyan com 66 3 Unscrew the USB Board 4 Disconnect the USB Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the USB Board ...

Страница 67: ...http www tyan com 67 3 6 1 USB Board Specifications M1717T65 USB USB Board Form Factor 48mmx19mm T 1 6mm Specifications USB 3 0 Connector 5 2PIN input Connector ...

Страница 68: ...1 Disconnect the fan cable to lift up the fan module 3 Use a screwdriver to press the latch and move the latch in the direction as the arrow shows to get off the fan cage 4 Follow the steps described earlier in reverse order to replace a new fan module into the chassis Remember to connect the fan cable ...

Страница 69: ...h the HDD backplane please remove all the HDD trays with HDDs otherwise the HDD backplane will be damage when strains at the disassembly 1 Disconnect all cables connected to the M1297T65 BP12E 12 HDD Backplane 2 Unscrew the HDD BP Board 3 Release the HDD Backplane from the hook ...

Страница 70: ...70 http www tyan com 4 Follow the procedures described earlier to reinstall the HDD backplane board bracket into the chassis ...

Страница 71: ...rd Features Front View Rear View M1297T65 BP12E 12 HDD Backplane Board Form Factor 431 2mmx 83mm T 2 7mm Specifications Overview 2x Slim SAS Connector Input 3x Mini SAS HD Connector Input 4x SGPIO Header 12x SATA HDD or 8 SATA HDD 4x NVMe Output ...

Страница 72: ...O3 Reserved for AMD Platform SGPIO1 Reserved Jumper setting for HDD backplane LED 3PHD1 2 3 close Mode select0 0 3PHD7 2 3 close Mode select1 0 Default Mode 00 AMD mode SGPIOA Decode PORT 0 7 SGPIOC Decode PORT 8 11 3PHD1 1 2 close Mode select0 1 3PHD7 2 3 close Mode select1 0 INTEL LSI RAID CARD mode 01 INTEL SAS3008 Mode SGPIOA Decode PORT 0 3 SGPIOB Decode PORT 4 7 SGPIOC Decode PORT 9 11 3PHD1...

Страница 73: ...o replace the M7100F48B PDB Power Distribution Board in your system 1 Disconnect all cables connected to the power distribution board 2 Unscrew to take off the power distribution board and replace with a new one 3 Insert the PDB into the chassis following the above procedures in reverse order ...

Страница 74: ...ion Board Features M7100F48B PDB Power Distribution Board Board Size 82MMx 127 3 MM T 1 6mm Integrated I O 3 8 pin power connector 3 4 pin power connector 2 20 pin power connector 1 24 pin power connector 1 PSMI connector 1 50 pin golden finger ...

Страница 75: ... Connector Definition Pin Pin Definition GND 1 2 GND 12V 3 4 5V PW6 PW7 PW8 8 pin Power Connector Definition Pin Pin Definition GND 1 5 12V GND 2 6 12V GND 3 7 12V GND 4 8 12V PW2 PW3 20 Pin Power Connector Definition Pin Pin Definition GND 1 11 12V GND 2 12 12V GND 3 13 12V GND 4 14 12V GND 5 15 12V GND 6 16 12V GND 7 17 12V GND 8 18 12V GND 9 19 12V GND 10 20 12V ...

Страница 76: ...om PW5 24 pin Power Connector Definition Pin Pin Definition 3 3V 1 13 3 3V 3 3V 2 14 NA GND 3 15 GND 5V 4 16 PS_ON GND 5 17 GND 5V 6 18 GND GND 7 19 GND PW_GD 8 20 NA 5VSB 9 21 5V 12V 10 22 5V 12V 11 23 5V 3 3V 12 24 GND ...

Страница 77: ...3 10 Replacing the Power Backplane Board Follow these instructions to replace the M7063F86 PBP Power Backplane Board 1 Unscrew to remove the bracket from the PDB tray 2 Unscrew the PDB tray and then slide it off the chassis ...

Страница 78: ...78 http www tyan com 4 Unscrew to replace with a new power backplane board 5 Follow the steps described earlier in reverse order to reinstall the power backplane board tray into the chassis ...

Страница 79: ...9 http www tyan com 3 11 Replacing the Rear HDD Backplane Board Follow the instructions to replace the M1298T65 BP12 2 HDD backplane Board 1 Disconnect all cables and unscrew the power distribution board ...

Страница 80: ...r View M1298T65 BP12 2 HDD Backplane Board Form Factor 33 5mmx76mm T 3mm Integrated I O Slimsas Connector J1 SATA NVMe Connector NVME0 SATA NVMe Connector NVME1 SATA Connector SATA0 SATA Connector SATA1 4P Power CON PW1 Header for PCA9544 SMBUS address Select 3PHD 1 ...

Страница 81: ... 11 2 HDD LED Definition LED Color State Description HDD fail LED Red ON NVME SATA HDD fail OFF No failure found HDD Power Access LED Green ON NVME SATA HDD ready Blinking NVME SATA HDD access activity OFF Power disconnected ...

Страница 82: ...ower Supply Follow these instructions to replace the power supply module in your system 1 Press the latch to pull the power supply out 2 After replacing a new power supply press and hold the latch to push the power supply back into the chassis ...

Страница 83: ...low to replace the motherboard from the chassis 1 Remove all components installed on the mainboard if there are any 2 Disconnect all cables connected to the motherboard 3 Remove nine screws securing the motherboard to the chassis 4 Carefully lift the motherboard from the chassis ...

Страница 84: ...84 http www tyan com NOTE ...

Страница 85: ...ent shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the motherboard model number Examples 5630 cap 7106 cap 7109 cap etc Please make sure that you are using the correct BIOS Recovery file from Tyan s web site BIOS Recovery Process 1 Place the recovery BIO...

Страница 86: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion is signified with the message Flash update completed Press any key to reset the system displayed on screen 8 Remove the USB disk and reboot If your system does not have video output or the POST code ha...

Страница 87: ...imSAS 8I to SlimSAS 8I SLIMSAS2 CN5 NVMW2_3 SlimSAS 8I to Mini SAS HD SATA0_3 J27 SATA0_3 SlimSAS 8I to Mini SAS HD SATA4_7 J25 SATA4_7 SlimSAS 8I to Mini SAS HD SATA8_11 J26 SATA8_11 HDR 7P Cable HDR1 J118 HDR4 Rear Backplane BP Board to S8253MB Cable Rear HDD BP M1298T65 BP12E 2 Connect to S8253GM2NE S8253GM4NE SATA 7P to SATA 7P SATA0 J48 SATA12 SATA 7P to SATA 7P SATA1 J49 SATA13 2 System FAN ...

Страница 88: ...Front Panel USB Cable Front Panel M1702T70 USB Connect to S8253GM2NE S8253GM4NE J2 J32 USB3 1 HDR 6 Power Supply Cables M7100F48B PDB Connect to S8253GM2NE S8253GM4NE PW3 J62 PWR3 J65 PER5 PW5 J60 PWR1 PW6 J63 PWR2 PW7 J64 PWR4 J1 J61 PSMI 7 Power Supply Cables M7100F48B PDB Connect to HDD BP M1297T65 BP12E 12 PW2 PW1 PW2 8 Power Supply Cables M7100F48B PDB Connect to Rear HDD BP M1298T65 BP12E 2 ...

Страница 89: ...ard A table of BIOS Temp sensor name explanation is also included for readers reference Figure 1 Sensor Location NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan speed rpm 2 Temp Sensor refer to Figure 1 Sensor Location They detect the system temperature around ...

Страница 90: ...90 http www tyan com BIOS Temp Sensor Name Explanation ...

Страница 91: ...OSFET Temperature of the P1_ SOC_MOSFET P0_DIM_MOSFET_1 Temperature of the P0_DIM MOSFET_1 P0_DIM_MOSFET_2 Temperature of the P0_DIM MOSFET_2 P1_DIM_MOSFET_1 Temperature of the P1_DIM MOSFET_1 P1_DIM_MOSFET_2 Temperature of the P1_DIM MOSFET_2 LAN_X550_Temp Temperature of the LAN_X550_Temp P0_UMC0_CH_A0 The highest temperature of CPU0 UMC0 channel A slot P0_UMC1_CH_B0 The highest temperature of CP...

Страница 92: ...of CPU1 UMC6 channel E slot P1_UMC7_CH_F0 The highest temperature of CPU1 UMC7 channel F slot P1_UMC5_CH_G0 The highest temperature of CPU1 UMC5 channel G slot P1_UMC4_CH_H0 The highest temperature of CPU1 UMC4 channel H slot BIOS FAN Sensor Name Explanation CPU0_FAN Fan speed of CPU0_FAN CPU1_FAN Fan speed of CPU1_FAN SYS_FAN_1 Fan speed of SYS_FAN_1 SYS_FAN_2 Fan speed of SYS_FAN_2 SYS_FAN_3 Fan...

Страница 93: ... com Appendix IV PCI E Slot Serial Number The Serial Number of the PCI E Slots on 6 5 via Riser Card are listed below Riser Card BIOS BMC PCI E 1 PCI E Up PCI E 7 PCI E 2 PCI E Middle PCI E 8 PCI E 3 PCI E Down PCI E 9 ...

Страница 94: ...er Up Slot Maximum Link Speed for Riser Up Slot Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Gen4 16 GT s Riser Middle Slot Maximum Link Speed for Riser Middle Slot Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Gen4 16 GT s Riser Down Slot Maximum Link Speed for Riser Down Slot Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Gen4 16 GT s ...

Страница 95: ... http www tyan com The user can also view the PCI Device Information for Riser Slots using the BMC Web UI BMC WEB UI System Inventory Information PCI Device Information A sample screenshot is given below ...

Страница 96: ...96 http www tyan com NOTE ...

Страница 97: ... FRU TA 0230 344T62600002 TF AIR DUCT SBU PC ABS TS65 B8253 PCBA FRU RC 1210 411T62600011 M8253T65 R32 3F Riser Card Rack Mounting Parts FRU AS 0200 452T60900002 Slide Rail Kit Cable FRU CS 1170 422T60900002 SlimSAS 8I to SlimSAS 8I FRU CS 1180 422T61300008 SlimSAS 8I to SlimSAS 8I FRU CS 1670 422T53400017 Mini SAS HD to Mini SAS HD FRU CS 0500 422T51400004 Mini SAS HD to Mini SAS HD FRU CS 0330 3...

Страница 98: ...98 http www tyan com NOTE ...

Страница 99: ...es such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find their latest software and operating system components to keep their systems running as powerful and productive as possible MITAC also ranks high for its commitm...

Страница 100: ...proper maintenance of products Note A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufacturer for a Return Merchandise Authorization RMA number The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid TYAN will pay ...

Отзывы: