IMPORTANT! Connect a suitable rated RF test load to the RF OUPUT
socket before connecting the unit to mains power. FAILURE TO DO SO
MAY RESULT IN DAMAGE NOT COVERED BY WARRANTY.
Never carry the transmitter by the front panel handle. This is provided
purely to pull the transmitter forward, to assist in removal from an
equipment rack.
Install the TXDAB350 in a suitable 19” equipment rack with adequate
clearance and cooling airflow. Use front-to-back rack supports on both
sides of the transmitter, and slide the unit into the rack. NEVER ALLOW
THE FRONT PANEL FIXINGS TO TAKE THE WEIGHT OF THE UNIT.
First, connect a suitably rated test load to the RF OUT socket on the
transmitter’s rear panel.
Connect the EDI feed(s), GPS antenna and then the mains lead.
Switch on the mains power.
Press the ‘OK’ key for 3 seconds to enter the settings menu.
Select the RF Power Output setting and reduce the power to its
minimum level. Press OK to store the value.
Now enter the desire channel frequency. Press OK to store the value.
Ensure that the RF Mute setting is disabled (OFF).
Enter the required TIST Hold value. Press OK to store the value.
Select the required mode (SFM or MFM). Press OK to store the value.
Set the required Delay amount. Press OK to store the value.
Set the TII MAIN identifier as required. Press OK to store the value.
Set the TII Local identifier as required. Press OK to store the value.
Select INPUT (EDI1). Enable the input, and enter the required network
settings. Press OK to store the values.
Installation