background image

Tunnel Electric Dishwashing Machine User Manual     

   

 

 

Instruction book OF TT-K134 / TT-K135 / TT-K136

 

Electric dishwashing machine 

 

A.

 

When water inflow to the machine 

 

Caution : please confirm whether the water-supply is suitable. Setting a water cleanness machine is 

must if the quality can’t reach the standard class , 

a

In order to be convenient to cut the water current and mend the machine when it is indeed, 

appropriate section machines connected to water supply system   

b

The water pressure which the water-supply system provide is need to be between 

1.5+1.9BAR(0.15+0.19MPA). 300~370 liter water hourly is used by C180/C250 washing machine. 

And over-pressure will cause temperature declining while washing. Another booster pumps should 

be installed if the water shortage. retrofitting regulator supposed to be installed in the inlet to reduce 

water pressure If there is    too much pressure. 

c

Connect 3/4 inch thread inlet water pipe to inlet of the machine which is in the bottom. 

d

Adjusted spillway in order that water discharge are not excessive. Spillway outlet should be 

connectted to the drainage.   

e

Take attention when attaching water: the choke to use to connect can stand above 70 degree and 

pressure from the machine. 

 

B.

 

The electric power allocation and installment   

 

a.  Model C180 needs tri-case and five-line power supply in 16 square and air leakage on-off 

over80A beside. 

 

b.  Model C250 needs independent tri-case and five-line power supply in 25 square and air leakage 

on-off over100A beside. 

 

c

  Let electric cable in standard rate pass the electric line inlet    of bottom.And make the cable 

connect to the related supply terminals of the machine that is inside of bridgeboard in the machine

 

 

d

Make the double core cable link to a form a complete set to on worktable. Line of the supply 

terminals is taken out before connection, and then connect the in-out tie line of the guard switch. 

The linking position of the switch 

 

 

C.

 

Dose allocator 

a.  Washing agent checked distributor of accessories are submitted. (Proper accessories : 

10-meter tube, one black one-way valve, one sensor probes, one injector, 2 inhalation of PVC tube, 

one pair of wall-mounted panels, one cable connector, 4 screw). A distributor will be fixed on the 

wall, dishwasher and steam away from the fuselage export guarantee access. (Machines after the 

shell hole is reserved for assembly mounted plate) 

b.    When the distributor of choice in terms of model should be installed probe. (Probe installation: 

water from the dishwasher 10CM place drilling a hole 22.5MM on the cylinder wall. Rubber gasket 

from fixed internal probe. with the heat probe, detergent entrance channel, Progressive pipes 

distance) 

c.    When lotion infuser is installed, you should drill a hollow with 22.5MM above the wash jar, and 

after that fasten infuser from inside with rubber washer 

 

d.  Quick-drying one way valve should be installed on the morsel in advance of the heater inflow 

valve. 

 

 

NO.18 - 105, HUAGANG GARDEN, ZHONGSHAN AVENUE, GUANGZHOU, CHINA 
T: 86-20-38768241 | F: 86-20-38769376 | 

WWW.TWOTHOUSANDCO.COM

 

 

Отзывы: