background image

 

- 3 - 

Table 2 

Model 

TP-3010 

TP-6005 

TP-3020 

TP-6010 

Constant voltage operation 

Line regulation 

≤0.01%+5mV

 

≤0.01%+5mV

 

≤0.01%+10mV

 

≤0.01%+5mV

 

Load regulation 

≤0.02%+5mV

 

≤0.02%+5mV

 

≤0.02%+10mV

 

≤0.02%+5mV

 

Ripple & Noise 

≤3mVrms

, 5Hz~1MHz 

Constant current operation 

Line regulation 

≤0.2%+3mA

 

Load regulation 

≤0.2%+3mA

 (I

3A) 

≤0.2%+5mA

 (I>3A) 

≤0.2%+15mA

 (I

10A) 

Ripple & Noise 

3mArms (I

3A) 

10mArms (I>3A) 

Display 

Voltmeter 

3 digits LED display 

Ammeter 

3 digits LED display 

Resolution 

100mV/10mA 

Accuracy 

Real voltage and current output: ±(1% 2 digits) 

Preset voltage and current: ±(1% 8 digits) 

General 

Operating environment 

0

~40

, ≤80%RH

 

Storage environment 

-10

~70

, ≤70%RH

 

Power source 

AC110V/220V±10%, 50/60Hz 

Accessories 

Power cord x1, Operation manual x1, Test lead x1 

Dimension 

255Wx155Hx370Dmm 

255Wx155Hx330Dmm 

In purpose of product improvement, specifications are subject to change without prior notice. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание TP Series

Страница 1: ...Single Channel DC Power Supply TP Series Operation Manual V1 0 BENCHTOP INSTRUMENT ...

Страница 2: ...CATORS 4 4 1 Panel Illustration 4 4 2 Front Panel Control 7 4 3 Rear Panel Control 8 5 OPERATION INSTRUCTIONS 8 5 1 Precaution 8 5 2 Setting Current Limit 8 5 3 Setting Constant Voltage 9 5 4 C C and C V Mode 9 6 MAINTENANCE 9 6 1 Fuse Replacement 9 6 2 Line Voltage Conversion 10 6 3 Cleaning 10 ...

Страница 3: ...to meet the requirements of modern circuit design The unit can be used as either constant voltage or current source It has output ON OFF fixed DC 5V 1A output optional digital LED display and overload protection circuits 2 PRODUCTION MODELS No Model Output Voltage Output Current Output ON OFF Fixed 5V 1A V A Preset Weight kg 1 TP 1303EC 0 30V 0 3A 4 5 2 TP 1305EC 0 30V 0 5A 5 3 TP 1603EC 0 60V 0 3...

Страница 4: ... Line regulation 0 2 3mA Load regulation 0 2 3mA 0 2 5mA 0 2 3mA Fixed output Only for TP 1303 1305 1603 Output voltage 5V 1 Output current 1A Ripple noise 3mVrms 5Hz 1MHz Display Voltmeter 3 digits LED display Ammeter 3 digits LED display Resolution 100mV 10mA Accuracy 1 reading 2 digits General Operating environment 0 40 80 RH Storage environment 10 70 70 RH Power source AC110V 220V 10 50 60Hz A...

Страница 5: ...oise 3mArms I 3A 10mArms I 3A Display Voltmeter 3 digits LED display Ammeter 3 digits LED display Resolution 100mV 10mA Accuracy Real voltage and current output 1 reading 2 digits Preset voltage and current 1 reading 8 digits General Operating environment 0 40 80 RH Storage environment 10 70 70 RH Power source AC110V 220V 10 50 60Hz Accessories Power cord x1 Operation manual x1 Test lead x1 Dimens...

Страница 6: ... 4 4 PANEL CONTROLS AND INDICATORS 4 1 Panel Illustration a TP 1303EC 1305EC 1603EC Front panel Fig 4 1 b TP 1303C 1305C 1603C Front panel Fig 4 2 ...

Страница 7: ... 5 c TP 1303 1305 1603 Front panel Fig 4 3 d TP 3010 6005 3020 6010 Front panel Fig 4 4 ...

Страница 8: ... 6 e 30V 3A 30V 5A 60V 3A Rear panel Fig 4 5 f TP 3010 6005 Rear panel Fig 4 6 ...

Страница 9: ...or Lights when the power supply is in constant current operation 5 C V indicator Lights when the power supply is in constant voltage operation 6 Voltmeter Indicates the output voltage 7 Ammeter Indicates the output current 8 Voltage Coarse For coarse adjustment of the output voltage 9 Voltage Fine For fine adjustment of the output voltage 10 Current Coarse For coarse adjustment of the output curre...

Страница 10: ...een any connection and earth ground CAUTION 1 The instrument must be operated under rated main supply If it is meant to work for a long time it is suggested to use 60 70 instead of full load so as to avoid rapid aging 2 Avoid frequent short circuit operations 3 In case of the instrument with full load do not turn on the instrument Before adding load adjust the voltage knob to the minimum value the...

Страница 11: ...it automatically changed into constant voltage mode Should check the load or increase the preset voltage value 6 MAINTENANCE WARNING The following instructions are for use by qualified personnel only To avoid electrical shock do not perform any servicing other than contained in the operating instruction unless you are qualified to do so 6 1 Fuse Replacement If the fuse blows the CV or CC indicator...

Страница 12: ...he AC line that it may be less than 207V 105V 6 3 Cleaning To clean the power supply use a soft cloth dampened in a solution of mild detergent and water Do not spray cleaner directly onto the instrument since it may leak into the cabinet and cause damage Do not use chemicals containing benzene benzene toluene xylene acetone or similar solvents Do not use abrasive cleaners on any portion of the pow...

Отзывы: