1. Package Contents

Product Manual / Warranty

4. Installation

8. Warranty Repair and Warranty Period

For warranty service, please contact your place of purchase.
  1) The warranty period is 1 year from the date of purchase (excluding the Reactor).
  2) This warranty does not apply where damage is caused by the Customer’s mishandling.
  3) The Customer must provide this Warranty Certificate to receive any services under this 
       warranty. 
  4) Please do not lose this Warranty Certificate as it will not be reissued. 
  5) For repairs beyond the warranty period, please ask dealership.
  6) The warranty period for the Reactor is 6 months from the date of purchase and it is possible
       to repurchase the Reactor.
  7) The Customer must also provide the label attached to the Product in order to receive any 
       services under this warranty. If the label is damaged, altered or removed, the Customer 
       cannot receive any services under this warranty.
 
This warranty does not apply if the Product is:
  1) improperly repaired, modified or disassembled;
  2) used for any purpose other than a freshwater aquarium;
  3) used for any purpose other than an ordinary household aquarium 
  4) damaged by Acts of God or other external causes, including but not limited to, fire, 
      earthquake, fluctuation or surges of electrical power and lightning.

5. Precautions regarding the Water Quality in Aquarium

6. Cleaning the Reactor

7. Safety Precautions

2. Names of parts

Reactor

3. Turning on the Power

TWINSTAR IC / TWINSTAR Reactor / Adapter / Suction Plates (3)

For optimal performance, please install the Reactor below 10~15cm of the Outflow.
Installing the Reactor in areas lacking water flow will cause reduction in performance.
 1) Fix the Suction cups to the back of the Reactor.
 2) Attach the Reactor below 10~15cm from the outflow in the tank.
 3) Fix the Suction cups to the back of the TWINSTAR IC.
 4) Once the Suction cups are fixed, attach the TWINSTAR IC to an appropriate area 
     on the aquarium’s outer wall. 
 5) Connect the Reactor Cable to the Power Output Terminal of the TWINSTAR IC.
 6) Connect the Extension Cable to the Power Input Terminal of the TWINSTAR IC 
     and connect the Extension Cable to the Adapter. 
 7) Push the Power Button and check that it is operating normally.

 1) Please completely remove any dust from the water for 3~5days before use.
 2) Please completely remove the algae that has already occurred in the tank before
     Installing TWINSTAR. It can not remove pre-existing algae.
 3) You must take the Reactor off from the water due to soil dust when you maintain tank
     or cut plant. Any dust in the water will shorten the life of the Reactor.
 4) Please keep the power input/output terminal away from the water. Otherwise, 
     this will Cause a failure in the operation of the terminal due to corrosion. 
     In case the terminal is exposed to water, drain as soon as possible and let it dry.
 5) Do not use this Product if you have put in salt in the water for medicated bath.
 6) TWINSTAR can not be together used with fish medicine.

1) The Reactors are consumables, requiring them to be replaced during use.
2) If you want to clean the Reactor, first, add 20cc of sodium hypochlorite to 1,000cc of
    water. Then, put the Reactor into the diluted solution for over 3 hours. Lastly, take out 
    the Reactor and wipe it with a soft sponge. You should  only clean the plastic part and 
    never clean the metal nets as the metal nets have special coating on them.

This Product is only to be used in a freshwater aquarium, and not to be used in a salt water
aquarium. Do not use this Product for any purpose other than those specified above. 
  1) Please read the Product Manual and use the Product according to the instructions in this 
      Product Manual. 
  2) Please ensure that there is no safety problem with the living thing (including aquarium fish)
      before installing the Product.
  3) Do not clean the metal nets of the Reactor.
  4) Please turn on the power after the Product has been completely installed.
  5) Do not put your hands into the aquarium once you have turned on the power. 
  6) Do not drop the Product or apply strong force to it.
  7) Please unplug the Power Cord when installing, removing, or retrieving the Product. 
  8) Please unplug the Power Cord if the Product is not to be used for a long time.
  9) Do not modify or disassemble the Product. Also, do not use the Product in any manner 
      other than those specified above.
10) Please keep the Product out of reach of children.

Pushing the Power Button will turn on the power and start the operation.

Model

M5

Shrimp 50

20L ~ 50L

50L ~ 120L

20L ~ 50L

50L ~ 100L

40L ~ 50L

50L ~ 100L

S5

Capacity

Mode 1

Mode 2

Date of Purchase

Customer’s Name

Address / Contact Number

Place of Purchase

01

 ENGLISH

TWINSTAR IC

Power output
terminal

Power input terminal

Power button/
Mode selection button

 Mode selection indicator
 Left : mode 1
 Right : mode 2

Содержание M5

Страница 1: ...Please completely remove the algae that has already occurred in the tank before Installing TWINSTAR It can not remove pre existing algae 3 You must take the Reactor off from the water due to soil dust when you maintain tank or cut plant Any dust in the water will shorten the life of the Reactor 4 Please keep the power input output terminal away from the water Otherwise this will Cause a failure in...

Страница 2: ...ie die Algen die bereits innerhalb des Aquariums vor der Installation des TWINSTARS aufgetreten vollständig der twinstar kann keine Bestandsalgen entfernen 3 Bei der Beckenpflege oder dem Beschneiden der Pflanzen entfernen Sie im Vorfeld die Elektrode aus dem Aquarium Der Staub im Wasser kann die Lebensdauer des Reactors reduzieren 4 Halten Sie bitte den Strom Eingangs Ausgangsanschluss des Steuer...

Страница 3: ...mpletamente tutte le alghe nell acquario prima di istallare TWINSTAR se l acquario non è di nuova istallazione TWINSTAR non elimina le alghe esistenti ma previene la formazione delle alghe 3 Tenere il TWINSTAR spendo durante la manutenzione della vasca Durante una pesante manutenzione delle piante e fondo è consigliabile rimuovere dalla vasca il reattore Tutte le polveri disciolte nel vostro acqua...

Страница 4: ...olvo 2 Antes de instalar el producto es necesario eliminar las algas existentes en el acuario pues TWINSTAR no las elimina 3 Debido al polvo del suelo quitar el Reactor del agua durante el mantenimiento del acuario y de las plantas Polvo en el agua reducirá la vida útil del Reactor 4 Por favor mantenga el terminal de entrada de energía terminal de salida de energía lejos del agua De otra manera pu...

Страница 5: ...eur du réservoir d eau avant d installer TWINSTAR Il ne peut pas supprimer les algues existantes 3 Vous devez éteindre et sortir le réacteur du bac lorsque vous procédez à l entretien Ceci à cause des poussières du sol où des résidus de plantes qui pourraient altérer le système 4 Se il vous plaît garder le terminal d entrée sortie de puissance loin de l eau Dans le cas contraire cela va provoquer ...

Страница 6: ... botão de alimentação e verifique se está a trabalhar 1 Remover totalmente qualquer poeira presente na água do aquário 3 5 dias antes de utilizar o TWINSTAR 2 Por favor remova as algas presentes no interior do seu aquário antes de proceder à instalação do TWINSTAR Visto que este não tem a capacidade de eliminar as algas 3 Retirar o reactor durante a realização da manutenção do aquário seja devido ...

Отзывы: