![Twinno T4046 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/twinno/t4046/t4046_operating-manual_1184523008.webp)
6
Instrument connection
Electrical connection
Connection between instrument and sensor: Connection of power supply, output signal, relay
contacts and instrument baseplate. The cable length of sensors is usually 5-10 meters. There are
labeled inserts at the end of the cable, which can be inserted into the terminal with the same
digital symbols on the instrument roof and tightened.
Terminal
SEN V+
SEN V-
SEN A
SEN B
N/C
Cur 1+
Com-
Cur 2+
RS485 B
RS485 A
SEN V+
SEN V-
SEN A
SEN B
N/C
N/C
N/C
N/C
N/C
Cur 1+
Com -
Cur 2+
RS485 B
RS485 A
NO 1
COM 1
NC 1
NO 2
COM 2
NC 2
Pow ACL
(85~265V)
Pow AC N
Pow PE
Function
Sensor power
Sensor power supply -
Sensor Communication A
Sensor Communication B
No connection
Current output 1+
Current output common
Current output 2+
Communication
Communication
Function
High set relay working position
Alarm relay common
High set relay resting position
Low set relay working position
Alarm relay common
Low set relay resting position
Live wire
Neutral wire
Earth wire
Terminal
NO 1
COM 1
NC 1
NO 2
COM 2
NC 2
Pow ACL(85-265V)
Pow AC N
Pow PE
(85-265V)
Digital Controller