background image

 

 
Daytona Twin Tec LLC, 933 Beville Road, Suite 101-H, S. Daytona, FL 32119 

       TCFI Log 

(386) 304-0700   

www.daytona-twintec.com

  

10/2007 

 Page 2 

Hewlett-Packard laser and inkjet printers and Epson 
inkjet printers. We recommend using a color inkjet 
printer. 

SOFTWARE INSTALLATION 

The software is supplied on CDROM media or in 

the form of a compressed file downloaded from our 
website. The installation process uses InstallShield. 
This industry standard installer is based the new 
Microsoft Windows Installer service that greatly 
reduces potential problems such as version conflicts 
and allows for application self-repair. Since Windows 
98 systems did not originally include the Windows 
Installer service, the required installer software is 
included in the distribution media.  

Before proceeding with installation, shutdown any 

other applications that may be running. For Windows 
Vista, you must disable the User Account Control 
(UAC) during installation. If you are not familiar with the 
UAC, please refer to the Vista UAC Tech Note on our 
website's Tech FAQ for details. 

Use the Windows Explorer or the Run command 

from the Windows Start Menu to launch setup.exe in the 
TCFI_Log folder on the CDROM or the setup.exe file 
downloaded from our website. InstallShield will install the 
software in an appropriate folder under Program Files. 

Once InstallShield has completed the 

installation, TCFI Log will appear on the Windows Start 
Menu. You can then launch it just as you would any 
other Windows program.  

TCFI Log requires the Monospace 821 BT fixed 

pitch printer font in order to properly align columns 
when printing. The Monospace 821 BT font is included 
in the distribution media and automatically copied to 
your Windows Fonts folder during installation. A 
backup copy is also placed in the program folder. If you 
accidentally delete this font, use the Install New Font 
command from the Fonts folder File menu. The 
filename associated with Monospace 821 BT is 
monos.ttf. 

TCFI CONNECTION  

If you are using the new USB Interface, refer to 

the supplied instructions for details. No additional 
hardware is required.  

If you are using the original RS-232 PC link 

cable, connect the cable to the OE data link connector 
and PC serial port. The OE data link uses a four 
terminal Deutsch connector that is usually found near 
the TCFI unit.  

Turn the ignition key and engine run/stop 

switches on to provide power to the TCFI unit. Do not 
start the engine if you want to download data. 

If the TCFI unit has been removed from the 

motorcycle, you can do bench top programming by 
using an adapter harness (P/N TCFI-ADAPT) that 
includes a small 12 volt DC power supply.  

COM1 is used as the default port. If you are 

using a different COM port, use the Port Setup 
command on the Communications Menu. 

REAL TIME ENGINE DATA DISPLAY 

When the engine is running, you can display real 

time engine data on an instrument panel type screen 
by using the View Real Time Data command on the 
View menu. Please note that real time engine data 
cannot be directly saved by means of the TCFI Log 
program. However, this data is constantly being logged 
by the TCFI unit and can be downloaded (for example 
at the end of series of dyno runs).  

Real time engine data is displayed on an 

instrument panel type layout with round tach and 
speedometer gauges and bar graph type gauges for 
most other parameters. Barometric pressure (In-Hg), 
any diagnostic codes, status of the user output, and 
status messages are displayed in additional windows. 
If the engine is not running most values will appear as 
zero. 

Displayed parameters include: 

RPM

 – engine crankshaft RPM (numeric value 

displayed beneath gauge) 

VSS

 – vehicle speed in MPH (numeric value 

displayed beneath gauge) 

TPS

 – throttle position (0 to 100%) 

MAP

 – manifold pressure in In-Hg (29.92 In-Hg 

corresponds to atmospheric pressure) 

ET

 – engine cylinder head temperature (deg C) 

IAT

 – intake air temperature (deg C) 

BAT

 – battery voltage 

IAC

 – idle air control stepper motor position 

(higher number means more idle air) 

 

 

 

Содержание TwinTec

Страница 1: ...Once data has been downloaded it is automatically displayed on a chart recorder type screen You can view the engine operating statistics by using the View Statistics command from the View menu You can...

Страница 2: ...e menu The filename associated with Monospace 821 BT is monos ttf TCFI CONNECTION If you are using the new USB Interface refer to the supplied instructions for details No additional hardware is requir...

Страница 3: ...oxygen sensor feedback shown as percent value from 75 125 Front and rear cylinder BLM values are displayed for TCFI IID units FRONT INJ PW REAR INJ PW injector pulse width in milliseconds FRONT ADV R...

Страница 4: ...king on the Print button a color inkjet printer is recommended for best results Data parameters include RPM engine crankshaft RPM VSS vehicle speed in MPH MAP manifold pressure in In Hg 29 92 In Hg co...

Страница 5: ...me Gear Ratio Display shows the calculated gear ratio RPM KPH at the cursor position This function is useful for determining the 6th gear ratio required for Module Parameter setup in PC Link TCFI IID...

Страница 6: ...The data is fairly self explanatory Total hours represents the total time that the engine was running ID represents the firmware identification This field typically includes the manufacturer Twin Tec...

Страница 7: ...the Communications menu The elapsed time data in the various RPM bands can be displayed in the form of a histogram chart by clicking on the Histogram button Color coding of the bars helps to interpret...

Страница 8: ...ORRECT COM PORT IS SELECTED IS PROBLEM FIXED CALL TECH SUPPORT YES FIRST TIME USE OF USB ADAPTER THAT WAS SUPPLIED BY A THIRD PARTY NOT SOLD AS PART OF OUR SYSTEM NO OTHER SOFTWARE ON PC THAT USES COM...

Отзывы: