TROUBLESHOOTING 

Problem

Root Cause

Corrective Action

Display shows “        ”

The thermostat sensor is

broken or disconnected.

Unplug the heater, remove the back panel of the heater and check that the 

thermostat is plugged into the main circuit board. If this does not solve the 

problem contact customer service for a replacement thermostat sensor.

Display shows “        ”

The thermostat sensor is 

broken.

Contact customer service for a replacement thermostat sensor. 

Display shows “       ”

Power cord overheating 

protection has activated.

Check your heater cord and plug connections.  Faulty wall outlet connections 

or loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tight 

in the outlet. Heaters draw more current than small appliances, overheating of 

the outlet may occur even if it has not occurred with the use of other appliances.  

During use check frequently to determine if your plug outlet or faceplate is 

HOT!  If so, discontinue use of the heater and have a qualified electrician check 

and/or replace the faulty outlet(s).

Heater does not blow 

warm air.

Cool down cycle

Normal operation, will continue to run for several minutes before shutting 

down.  Times will vary based on temperatures. During this time cool air will 

blow.

Dirty filters

Clean the filter gently with a vacuum.

Not reaching set 

temperature.

Perform a master reset; turn off and unplug unit.  Hold down main power but

-

ton on the unit itself.  Continue to hold button down while plugging unit back 

in.  Once unit is plugged back in continue to hold button for 5 seconds and then 

release.  Turn unit back on and temperature should flash 72 degrees then display 

the ambient room temperature.  

Not reaching set 

temperature.

Unit is designed to be used as a supplemental heat source in conjunction with a 

primary heat source.  

Temperature display not 

matching room 

temperature read by other 

thermostats.

Calibration

Press and hold timer button, 00 flashes then a single digit between -9 degrees to 

9 degrees will appear.  At this point release the timer button and use the arrow 

up/down button to adjust the temperature variance up to 9 d/- .  After 

10 second without control input the heater will exit thermostat calibration.  

The heater is taking a long 

time to reach desired room 

temperature.

Dirty filter 

Clean the filter gently with a vacuum.

Improper use of unit

Unit is designed to be used as a supplemental heat source in conjunction with a 

primary heat source.  

Location

Your unit should always be positioned on an inside wall with proper insulation.  

The heater provides supplemental heating for up to 1000 sq/ft in conjunction 

with a primary heat source. 

Location

The back and side of the heater should be greater than 6 inches away from ob

-

jects for proper air intake.

Use of surge protector/ 

extension cord.  

Plug unit directly into the wall outlet.

Temperature will not 

change.

Defective control panel 

circuit board.

Replace control panel circuit board.

Heater does not turn on 

but other functions work 

fine.

Manual reset needed

Turn the POWER to “OFF” and unplug the unit from the wall outlet for 5 min

-

utes. After 5 minutes plug the unit back into wall outlet, and operate as normal. 

If the problem persist contact customer service.

Unit continues to run after 

reaching set temperature/

or powering off.

Cool down cycle

Normal operation, will continue to run for several minutes before shutting 

down.  Times will vary based on heating. UNIT WILL BLOW COOL AIR.

Heat turns on randomly.

Ambient room 

temperature scan.

Normal operation, unit will periodically run to test air temperature.  

Will run 3 minute of cool air and 3 minutes of warm air.  

Buttons do not work.

Defective control panel 

circuit board.

Replace control panel circuit board.

Display does not 

illuminate.

Defective control panel 

circuit board.

Replace control panel circuit board.

How many quartz heating 

elements are in my unit? 

9QI product Inquiry.

6  Infrared Quartz heating elements.

Remote Control is not 

working.

No batteries or battery 

power.

Change the remote batteries.

poor signal

Operate remote transmitter at a slow measured pace. Press the remote control 

buttons with an even motion and gentle pressure. Repeatedly pressing buttons in 

rapid succession may cause the transmitter to malfunction.

Distance

Operate the remote at a distance less than 20 feet from the front of the 

appliance; point the remote at the control panel.

Содержание Duraflame 9HM7253

Страница 1: ...ay Beach FL 33445 Made in China Printed in China Fabricado en China Impreso en China Fabriqu en China Imprim en Chine www tsicustomerservice com 1 800 318 9373 MODEL MOD LE MODELO 9HM7253 INSERT MODEL...

Страница 2: ...CADO POR CSA C22 2 N 46 1 866 661 1218 www tsicustomerservice com SN AB 12345 A Date Code Code de Date C digo Fecha PRODUCT SPECIFICATIONS VOLTAGE 120VAC 60 Hz AMPS 12 5 Amps WATTS 1500 Watts 1 The se...

Страница 3: ...ions Never locate this appliance where it may fall into a bathtub or other water container 10 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away fr...

Страница 4: ...www tsicustomerservice com A165 4 OPERATION INSTRUCTIONS The heater can be operated by either the remote control or the control panel Control Panel Display Power Timer Temperature...

Страница 5: ...ss of the timer button won t change the previous setting Pressing the timer button will activate the timer display When the timer is active the display will count down from 60 seconds before shutting...

Страница 6: ...the temperature variance up to 9 degrees After 10 second without control input the heater will exit thermostat calibration The heater is taking a long time to reach desired room temperature Dirty fil...

Страница 7: ...ft cloth DO NOT use brass polish or household cleaners as these products will damage the metal trim Citrus oil based products can be obtained at supermarkets or hardware stores Periodic cleaning vacuu...

Страница 8: ...an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Oper...

Страница 9: ...ssume responsibility for same 6 The owner user assumes all other risks if any including the risk of any direct indirect or consequential loss or damage arising out of the use or inability to use the p...

Страница 10: ...osterior de la calentador el n mero de serie es necesario para el registro de la garant a del producto y el servicio de atenci n al cliente MOVABLE HEATER MEUBLE CHAUFFANT CALENTADOR DE MUEBLES MADE I...

Страница 11: ...este calentador donde se pueda caer dentro de una ba era u otro contenedor de agua 10 No coloque el cable debajo de una alfombra No cubra el cable con alfombras tapetes o similares Coloque el cable le...

Страница 12: ...www tsicustomerservice com A165 12 El calentador puede ser operado por el control remoto o el panel de control Pantalla Encendido Temporizador Temperatura INSTRUCCIONES DE OPERACI N Panel de control...

Страница 13: ...iguraci n de temperatura y mostrar la temperatura ambiente actual CONFIGURACI N DE LA TEMPERATURA Despu s de que el calefactor se ha encendido el ventilador seguir funcionando durante un per odo para...

Страница 14: ...la habitaci n No llega a la temperatura establecida La unidad est dise ada para ser usada con un calentador supletorio en conjunci n con la fuente de calor primaria La temperatura establecida no igua...

Страница 15: ...ecte la alimentaci n antes de intentar realizar mantenimiento o limpieza a fin de reducir el riesgo de incendio descarga el ctrica o lesiones personales VISTA DESPLEGADA CUIDADO Y MANTENIMIENTO Los bo...

Страница 16: ...ceptor Solicitar ayuda al concesionario o a un t cnico con experiencia en radio TV Este dispositivo cumple con la secci n 15 de las reglas de la FCC El funcionamiento est sujeto a las siguientes dos c...

Страница 17: ...me todos los riegos si los hay incluidos los riesgos de da os o p rdidas directos indirectos o resultantes que surjan del uso del producto o de la incapacidad para usarlo salvo que la ley estipule lo...

Страница 18: ...ie est situ l arri re du chauffage et le num ro de s rie est requis pour l enregistrement de la garantie du produit et pour le service la client le MOVABLE HEATER MEUBLE CHAUFFANT CALENTADOR DE MUEBLE...

Страница 19: ...enant rempli d eau 10 vitez de placer le cordon sous un tapis Ne couvrez pas le cordon avec une carpette un tapis de passage ou un autre article semblable Placez le cordon dans un endroit peu passant...

Страница 20: ...omerservice com A165 20 Le chauffage peut tre activ soit par la t l commande ou par le panneau de commande Panneau de contr le Affichage Alimentation Minuterie R glage de la temp rature INSTRUCTIONS D...

Страница 21: ...sort du mode de r glage de temp rature et indique la temp rature ambiante actuelle R GLAGE DE LA TEMP RATURE Apr s que le chauffage aura fonctionn le ventilateur continuera de fonctionner pour une cer...

Страница 22: ...jointement avec un syst me principal de chauffage L affichage de la temp ra ture ne correspond pas la temp rature de la pi ce lue par d autres thermostats Calibrage Maintenir enfonc la touche minuteri...

Страница 23: ...uire les risques d incendie de choc lectrique et de blessures corporelles VERTISSEMENT D brancher l alimentation lectrique avant l entretien ou le nettoyage afin de r duire les risques d incendie de c...

Страница 24: ...ircuit que celui du r cepteur obtenir de l aide aupr s du d taillant ou d un technicien en radio ou en t l vision exp riment Cet appareil est conforme l alin a 15 du r glement de la FCC Son utilisatio...

Страница 25: ...ateur assume tous les risques le cas ch ant incluant le risque de pertes ou dommages directs indirects ou cons cutifs d coulant de l utilisation de l appareil ou de l incapacit utiliser l appareil sau...

Страница 26: ...www tsicustomerservice com A165 26 www tsicustomerservice com...

Отзывы: