www.tsicustomerservice.com
A549
13
EXPLODED VIEW
CARE AND MAINTENANCE
• The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and require no
further lubrication. However, we recommend periodic cleaning/vacuuming of the fan/heater.
• Clean the trim using a soft cloth, slightly dampened with citrus oil based product and buff with a clean soft cloth.
DO NOT use brass polish or household cleaners as these products will damage the metal trim. Citrus oil based products
can be obtained at supermarkets or hardware stores.
• Make sure the unit is turned OFF and unplugged before cleaning the heater or fireplace.
Part
Part Name
Part Number
1
Front Glass with Frame
Y17-S215-P27
2
Emberbed with Logset
Y17-S215-P02
3
Emberbed Circuit Board
Y17-S215-P44E
4
Flame Circuit Board
Y17-S215-P40
5
Flame Generator Drive Motor
P10-6-Q
6
Control Panel Circuit Board
Y17-S215-P32
7
Main Circuit Board
Y17-S215-P15
8
Thermostat Sensor
INS-NTC
9
Heater/Blower Assembly
Y17-S215-P01
10
Remote Control
P136