Instructions for Installation 

 CPI 12 

 

Version 2.1 - march 2007 

 
 

Please go trough the instructions, before installing!  

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Nørrevangen 7   

   

DK-9631 Gedsted   

   

Phone  +45 98645222   

   

Fax. +45 98645244 

Mail: [email protected]   

   

Web: www.twinheat.dk   

Содержание CPI 12

Страница 1: ...ns for Installation CPI 12 Version 2 1 march 2007 Please go trough the instructions before installing Nørrevangen 7 DK 9631 Gedsted Phone 45 98645222 Fax 45 98645244 Mail twinheat twinheat dk Web www twinheat dk ...

Страница 2: ... 2 Connection to sprinkler system page 3 Connection to chimney page 3 Electrical connection page 3 Diagram 1 Connection to heating surface page 4 Diagram 2 Connection to chimney page 5 Diagram 3 Electrical diagram 400V 3 phase page 6 Diagram 3 1 Electrical diagram 230V 1 phase page 7 ...

Страница 3: ...re shows the minimum measures in mm that must be kept in the boiler room in order to operate the fuel store as intended The boiler room must have an air inlet Connection to heating surface See diagram 1 The water returning to the boiler must always be at least 60 65ºC hot when using wood pellets and at least 65 70ºC when using grains or wood chips If the above is not respected the corrosion of the...

Страница 4: ...nt to check that the valve is closing properly Dirt ore the like in the valve seat can prevent this Connection to chimney See diagram 2 The flue pipe must be insulated with a 50 mm fire resistant mat to avoid that the flue gasses are condensing in it It is highly recommended to mount a draught stabilizer on the flue pipe ore directly in the chimney The draught stabilizer is to be adjusted to 10 Pa...

Страница 5: ...urn and supply cold water 3 ways thermostatic mixing valve shunt V4 The shunt is to provide a homogenous temperature of the return water to the boiler app 60 70 C Air relief V5 Placed where needed Safety valve 2 5 bar V6 Thermometer T1 T2 Temperature sensor Tf For regulating the mixing valve Manometer M1 Manometer for boiler pressure Pump P Circulating pump for boiler and heating surface A B AB Tf...

Страница 6: ...ction to chimney The chimney must never be placed directly on the stoker Fig 2 Brick build chimney Cpi 12 Elbow Ø133x87 with mudhole Draught stabilizer Cpi 12 Cpi 12 Elbow Ø133x87 with mudhole Draught stabilizer Fig 1 Module chimney steel ...

Страница 7: ...6 DIAGRAM 3 Diagram 3 Electrical diagram 400V 3 phase ...

Страница 8: ...7 DIAGRAM 3 1 Diagram 3 1 Electrical diagram 230V 1 phase ...