LIQUID PROPANE GAS CONNECTION – T
WIN
E
AGLES
T
EPPANYAKI
G
RIDDLE
If your Teppanyaki Griddle is for Liquid Propane application, a factory supplied L.P regulator is set for 11” WC and
is for use with L.P. gas only. The factory-supplied regulator and hose must be used with a 20 lb. L.P. cylinder.
LP Gas Hose
• The gas supply hose should be inspected prior to each use. Do not use a gas hose that has abrasions, cuts, or
excessive wear.
•The gas supply must be turned off at the LP Gas supply cylinder and the LP Gas supply cylinder must be
disconnected from the regulator when this outdoor cooking gas appliance is not in use.
• When your Teppanyaki Griddle is stored indoors, remove and store the LP Gas cylinder outdoors in a protected,
cool, and dry location out of reach of children. The cylinder should not be stored in a building, garage, or any other
enclosed area.
LP gas cylinder
• Store the cylinder in an upright position so that the cylinder valve is at the top. This will ensure proper vapor
withdrawal.
•The cylinder used must include a collar to protect the cylinder valve.
• Store any spare or extra gas cylinder(s) at least 15 feet from the Teppanyaki Griddle other open flame, heat-
producing appliance(s) or heat source in a cool, well-ventilated outdoor location.
Note:
An enclosure for LP gas cylinder must be vented on the level of the cylinder valve and at floor level.
The effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP gas supply
cylinder in place. This shall be accomplished by one of the following:
a.
One side of the enclosure shall be fully open; or
b.
For an enclosure having four sides, a top and a bottom: At least two ventilation openings at
cylinder valve level shall be provided in the sidewall, equally sized, spaced at 180 degrees (3.14 rad),
and unobstructed. Each opening shall have a total free area of not less than 1/2 square inch per pound
(7.1 cm
2
/kg) of stored fuel capacity and not less than a total free area of 10 square inches (64.5 cm
2
).
c.
Ventilation opening(s) shall be provided at floor level and shall have a total free area of not less
than ½" square inch per pound (7.1 cm2/kg) of stored fuel capacity and not less than a total free area
of 10 square inches (64.5 cm2). If ventilation openings at floor level are in a sidewall, there shall be at
least two openings. The bottom of the openings shall be at floor level and the upper edge no more than
5 inches (127 mm) above the floor. The openings shall be equally sized, spaced at 180 degrees (3.14
rad) and unobstructed.
6