TYPICAL INSTALLATIONS
(continued)

SUSPENDED CEILINGS

Housing hung with wires - 3-point mount.

INSTALL THE HOUSING

1. Choose the location for your fan in the ceiling. For best possible

performance, use the shortest possible duct run and a minimum
number of elbows.

2. Position mounting brackets against joist so that bottom

edge of housing will be flush with finished ceiling.

Additional positioning feature for 5/8”, 1”, & 1-1/4”
thick ceiling material:

Holes in corners of housing are labeled with various
ceiling material thicknesses. Position housing so bottom
edge of joist is visible through a matched set of holes.
The housing is now in the proper position for that ceiling
material thickness.

Additional positioning feature for 1/2” thick ceiling
material:

Bend two tabs, on side of housing, 90

0

 outward. Lift

housing until tabs contact underside of joist.

Mark the keyhole slot on both mounting brackets.

3. Set housing aside and drive nails partially into joist at the top of

both keyhole marks.

4. Hang housing from nails and pound nails tight. To ensure a noise-

free mount, pound another nail through the top hole of each
mounting tab.

New Construction

INSTALL THE HOUSING
(continued)

New Construction

Existing Construction

2. In attic, position mounting brackets against joist. Trace outline of

housing on ceiling material.

3. Set housing aside and cut ceiling opening slightly larger than

marked.

1. Choose the location for your fan in the ceiling. For best possible

performance, use the shortest possible duct run and a minimum
number of elbows.

5/8

1

1-1/4

TAB

HOLES

BOTTOM EDGE OF JOIST

MOUNTING

TAB

GRILLE

SUSPENDED

CEILING MATERIAL

POWER

CABLE

4" ROUND

DUCT

HOUSING

MODEL  T080 

Содержание T080

Страница 1: ...ioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities CEILING VENTILATOR READ AND SAVE THESE INSTRUCTIONS Installer Leave this manual with the homeowner Homeowner Use and Care information on page 4 WARNING 6 Ducted fans must always be vented to the outdoors 7 If this unit is to be installed...

Страница 2: ...ick ceiling material Bend two tabs on side of housing 900 outward Lift housing until tabs contact underside of joist Mark the keyhole slot on both mounting brackets 3 Set housing aside and drive nails partially into joist at the top of both keyhole marks 4 Hang housing from nails and pound nails tight To ensure a noise free mount pound another nail through the top hole of each mounting tab New Con...

Страница 3: ...ible to unit Do not allow cable to touch sides or top of unit after installation is complete 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive another nail through the top hole of each mounting bracket Existing Construction 5 Additional mounting holes are provided for installations...

Страница 4: ... of seller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such de fects by buyer or within ten 10 days after such defects should reasonably have been discovered whicheve...