MODELS 

 T900 

 T1500

22"

22"

1

1

/

8

"

MAX.

18"

1½"

to

2½"

MOUNTING OPTIONS

WIRING OPTIONS

DUCTING OPTIONS

(Outlet parallel to joists.)

(New construction)

¼-20 hex nuts secure mounting brackets to housing. Loosen and

re-tighten or remove and replace nuts as necessary for desired

mounting bracket position.

(Outlet perpendicular to joists.)

(New or Existing construction)

BLOWER DISCHARGE POSITIONS

WIRING PLATE

POSITION

HORIZONTAL POWER

CABLE CONNECTION

VERTICAL

POWER

CABLE

CONNECTION

DUCT

CONNECTOR

(this side)

MOVABLE

PANEL

DUCTING

(Vertical blower discharge)

ROOF CAP

12” ROUND DUCT

WARNING: To reduce the risk of electric shock,

disconnect from power supply before servicing.

To clean grille:

 Use appropriate vacuum attachment or remove

grille  and clean with a soft cloth and mild soap or detergent. Dry

grille thoroughly before reinstalling.

To clean blower assembly:

 Remove grille, unplug blower from

housing, remove blower mounting nuts, and carefully remove blower

from housing. Use appropriate vacuum attachment or a soft cloth

and mild soap or detergent to clean blower discharge area and

wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure

blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.

USE AND CARE

Ventilator is designed for continuous operation. If desired, it may

be controlled using an on/off switch or a solid-state, variable speed

control. Follow wiring instructions packed with control, and adhere

to all local and state codes, and the National Electrical Code.

18"

1½"

to

2½"

Factory-shipped

Horizontal

discharge

Factory-shipped

Horizontal

discharge

Housing

Converted to

Vertical Discharge

(Outlet vertical.)

(New or Existing construction)

(Outlet parallel to joists.)

(New or Existing construction)

Factory-shipped

Horizontal

discharge

DUCT

CONNECTOR

(this side)

MOVABLE

PANEL

(Change to this

location)

8” X 12” TO

12” ROUND

TRANSITION

Mounting brackets in 

factory-shipped position, 

mounted directly to joists.

Mounting brackets flipped 

over and mounted to 

additional framing.

Mounting brackets flipped 

over and mounted to 

additional framing

Mounting brackets flipped 

over and mounted to 

top of housing. Housing 

secured with cables.

Wiring plate mounts to side or top of housing.

Typical ductwork connection to a ventilator

converted to vertical discharge.

Ventilator shown in 

horizontal discharge position 

(factory shipped).

Ventilator shown in

vertical discharge position 

(change movable panel to 

new location as shown).

Содержание T050

Страница 1: ...l ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 Please read specification label on product for further information and require ments WARNING INSTALLATION MODEL T050 HOUSING FLAP HOUSING LINE IN RECEPTACLE GROUND WIRECLIP DETAIL SWI...

Страница 2: ...discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such defects by buyer or within ten 10 days after such defects should reasonably have been discovered whichever is less b the defective unit is returned to seller transportation charges prepaid by buyer c payment in full has been re...

Страница 3: ...ioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities CEILING VENTILATOR READ AND SAVE THESE INSTRUCTIONS Installer Leave this manual with the homeowner Homeowner Use and Care information on page 4 WARNING 6 Ducted fans must always be vented to the outdoors 7 If this unit is to be installed...

Страница 4: ...ick ceiling material Bend two tabs on side of housing 900 outward Lift housing until tabs contact underside of joist Mark the keyhole slot on both mounting brackets 3 Set housing aside and drive nails partially into joist at the top of both keyhole marks 4 Hang housing from nails and pound nails tight To ensure a noise free mount pound another nail through the top hole of each mounting tab New Con...

Страница 5: ...ible to unit Do not allow cable to touch sides or top of unit after installation is complete 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive another nail through the top hole of each mounting bracket Existing Construction 5 Additional mounting holes are provided for installations...

Страница 6: ... of seller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such de fects by buyer or within ten 10 days after such defects should reasonably have been discovered whicheve...

Страница 7: ...en cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Neve...

Страница 8: ...ite sides of housing upside down so housing is flush with finished ceiling DUCTING Horizontal blower discharge ROOF CAP ROUND ELBOW ROUND DUCT WALL CAP IMPORTANT Remove shipping tape from damper Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight Remove shipping ring...

Страница 9: ...ing nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Ventilator is designed for continuous operation If desire...

Страница 10: ...eller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such defects by buyer or within ten 10 days after such defects should reasonably have been discovered whichever is l...

Страница 11: ...cable codes and stan dards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Societ...

Страница 12: ...X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing upside down so housing is flush with finished ceiling DUCTING Horizontal blower discharge ROOF CAP 10 ROUND ELBOW 10 ROUND DUCT WALL CAP NOTE Make sure the shipping tape is removed from the damper flap and that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure ...

Страница 13: ...r mounting nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Ventilator is designed for continuous operation If...

Страница 14: ...ver occurs first The liability of seller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer duringsuch period provided that a seller is notified in writing within ten 10 days following discovery of such defects by buyer or within ten 10 days after such defects should reasonably h...

Страница 15: ...ing or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Never place...

Страница 16: ... flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight 8 X 12 TO 12 ROUND TRANSITION 8 X 12 TO 12 ROUND TRANSITION 12 ROUND DUCT FINISHED CEILING MATERIAL Ventilator factory shipped in horizontal discharge position MOUNTING BRACKETS factory shipped in position for ceiling material 8 X 12 TO 12 ROUND TRANSITIO...

Страница 17: ...er assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Ventilator is designed for continuous operation If desired it may be controlled using an on off switch or a solid state variable speed control Follow wiring instructions packed with control and adhere to all local and state codes and the National Electrical Code 18 1 to 2 ...

Страница 18: ...ate of shipment whichever occurs first The liability of seller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such defects by buyer or within ten 10 days after such defe...

Отзывы: