background image

wire cutting station

2-4

 

 

 

SM-

qWt-120

intRoduction and descRiption

2.01 How to Use this Manual

To ensure safe operation, read the entire manual, including 

the chapters on safety instructions and warnings.
Throughout this manual, the words 

WARNING

,

 CAUTION

and

 NOTE

 may appear.  Pay particular attention to the 

information provided under these headings.  These special 

annotations are easily recognized as follows:

  WARNING

WARNING gives infoRMation RegaRding 

possible peRsonal injuRy.

 CAUTION

a  CAUTION  refers  to  possible  equipment 

damage.

NOTE

NOTE offers helpful information concerning 

certain operating procedures.

2.02 Receipt of Equipment

When  you  receive  the  equipment,  check  it  against  the 

invoice  to  make  sure  it  is  complete  and  inspect  the 

equipment for possible damage due to shipping.  If there is 

any damage, notify the carrier immediately to file a claim.  

Furnish complete information concerning damage claims 

or shipping errors to the location in your area listed in the 

inside back cover of this manual.  Include a full description 

of the parts in error.
If you want additional or replacement copies of this CD, 

please contact Tweco

®

 Robotics at the address and phone 

number in your area listed on the inside back cover of this 

manual.  Include the Manual number (from page i) and 

CD part number: 64-2601.

2.03 Introduction

The Tweco

®

 Robotics QWT-120 Quick Wire Trimmer, is 

an on-the-fly wire trimming station furnished with dual 

cutting wheels as shown in Figure 1 that cleanly shear the 

wire without deflection or bending of the welding wire.   

SECTION 2:  

INTRODUCTION AND DESCRIPTION

2.04 Features

Machined discs from heat-treated tool steel for long 

life and economical performance. 

Reversible cutting discs, doubles the disc’s life span, 

designed for convenient replacement.

Unit is powered by a 120-volt AC motor with a relay 

interface  for  controlling  the  start  and  stop  cycle 

through the robotic controller.

Unit is enclosed in a heavy-gauge aluminum tube, 

with  the  head  assembly  machined  from  solid 

aluminum. 

Industrial  components  provide  years  of  reliable 

service.

The unit is able to cut the following wire sizes:

Steel Wire

From .023” (0,6mm) to 5/64” (2,0mm)

Aluminum 

Wire

From .030” (0,8mm) to 3/32” (3,2mm)

Flux Cored 

Wire

From .030” (0,8mm) to 3/32” (3,2mm)

Metal Cored 

Wire

From .030: (0,8mm) to 3/32” (3,2mm)

5.00”
(127mm)

17.00”
(432,5mm)

7.50”
(190,5mm)

5.00”
(126,4mm)

Figure 1

Содержание qwt-120

Страница 1: ...0 60 Hz 1 PHASE GTAW SMAW INVERTER CC DC 115 V 230 V Version No AA 01 Issue Date July 1 2006 Manual No SM QWT 120 wire cutting station installation and Operation guide English Fran ais Espa ol qwt 120...

Страница 2: ...ead the entire manual especially the Safety Precautions They will help you to avoid potential hazards that may exist when working with this product YOU ARE IN GOOD COMPANY The Brand of Choice for Cont...

Страница 3: ...X 76208 940 566 2000 www tweco com Copyright 2006 by Thermadyne Industries Inc All rights reserved Reproduction of this work in whole or in part without written permission of the publisher is prohibit...

Страница 4: ...ty and Health 1 3 SECTION 2 INTRODUCTION AND DESCRIPTION 2 4 2 01 How to Use this Manual 2 4 2 02 Receipt of Equipment 2 4 2 03 Introduction 2 4 2 04 Features 2 4 Section 3 Installation and Operation...

Страница 5: ...warm surroundings where perspiration is a factor the use of reliable automatic controls for reducing the no load voltage is recommended to reduce shock hazard 7 When the welding or cutting process re...

Страница 6: ...noise 11 Keep smoke fumes and gases from the breathing area 12 Fumesfromtheweldingorcuttingprocessareofvarious typesandstrengths depending onthekindof base metal being worked on To ensure your safety...

Страница 7: ...AND OPERATING REFERENCES 1 Code of Federal Regulations OSHA Section 29 Part 1910 95 132 133 134 139 251 252 253 254 and 1000 U S Government Printing Office Washington DC 20402 2 ANSl Z49 1 Safety In...

Страница 8: ...itional or replacement copies of this CD please contact Tweco Robotics at the address and phone number in your area listed on the inside back cover of this manual Include the Manual number from page i...

Страница 9: ...AC power cord into the appropriate receptacle The motor is controlled by a 24 volt DC relay circuit built into the unit The operational mode switch activates the relay circuit The unit comes with a 22...

Страница 10: ...ation 4 6 SM QWT 120 SECTION 4 wiring diagram wiring diagram 1 3 8 2 4 5 momentary test Off Auto switch cap motor blue brown green power cord 120 v AC signal 24v dc black red control wire R1 R2 R3 R4...

Страница 11: ...SECTION 5 replacement parts Part No QWT 120 9 Stock No 3500 1309 Part No QWT 120 6 Stock No 3500 1306 Part No QWT 120 19 Stock No 3500 1319 Part No QWT 120 2 Stock No 3500 1302 Part No QWT 120 4 Stoc...

Страница 12: ...ve the necessary equipment and tools to perform repairs Other key benefits in considering the FRC service repairs on your product All products will be rebuilt and tested following the established test...

Страница 13: ...n The remedies of the Purchaser set forth herein are exclusive and the liability of THERMADYNE with respect to any contract or anything done in connection therewith such as the performance or breach t...

Страница 14: ...tric Motors Coolant Recirculators 1 year 1 year SMAW Stick Welding Equipment Parts Labor Dragster 85 Original Main Power Magnetics 1 year 1 year Original Main Power Rectifiers Control P C Boards 1 yea...

Страница 15: ...5 Ding Xi Rd Chang Ning District Shanghai PR 200052 Telephone 86 21 6280 1273 Fax 86 21 3226 0955 Thermadyne Asia Sdn Bhd Lot 151 Jalan Industri 3 5A Rawang Integrated Industrial Park Jln Batu Arang 4...

Страница 16: ...World Headquarters Thermadyne Holdings Corporation Suite 300 16052 Swingley Ridge Road St Louis MO 63017 Telephone 636 728 3000 Fascimile 636 728 3010 www thermadyne com...

Отзывы: